Brand:

Omron CP2E-N40DR-A CP2E 40-Point N-Type CPU Unit

Description

CP2E-N40DR-A: CP2E Network model CPU with 40 I/O points

The CP2E-N40DR-A is an Omron CP2E micro PLC CPU unit and the mid-size 40-point Network CPU. It carries 40 built-in I/O points (24 DC inputs and 16 relay outputs), runs from 100 to 240 VAC and offers 10K steps of program capacity with 16K words of data memory. Seven Star LLC supplies the CP2E-N40DR-A in Oman and the GCC as an independent supplier based in Muscat, not affiliated with the manufacturer, and this page explains the part number, the numbers that matter for selection and what to check before an enquiry.

In practice the CP2E-N40DR-A suits a packaging, conveying or pumping skid that has outgrown 30 points but does not need the 60-point body. The CP2E range is divided into three classes, Essential (E), Standard (S) and Network (N), and the CP2E-N40DR-A sits in the network model class.

Decoding the part number CP2E-N40DR-A

The CP2E model number is a compact code. Each segment fixes one property of the CPU unit, and the table below reads the code in the order it is written.

Segment Meaning in CP2E-N40DR-A Choices in the CP2E range
CP2E CP2E micro PLC family Single family name
N Network model E Essential, S Standard, N Network
40 40 I/O points (24 inputs, 16 outputs) 14, 20, 30, 40 or 60 points depending on class
D DC input type DC inputs only
R Relay outputs R relay, T transistor sinking, T1 transistor sourcing
A AC power supply, 100 to 240 VAC A AC supply, D DC supply

CP2E-N40DR-A technical specifications

Parameter Specification
Manufacturer / part number Omron / CP2E-N40DR-A
Class Network model (CP2E-N type)
Built-in I/O 40 points: 24 inputs, 16 outputs (relay outputs)
Supply voltage 100 to 240 VAC, 50/60 Hz, operating range 85 to 264 VAC
Program capacity 10K steps (function block capacity 10K steps)
Data memory 16K words; DM backup 15,000 words
Overhead processing time 0.2 ms
Instruction execution time LD 0.23 µs, MOV 1.76 µs; approximately 220 instructions
Current consumption 5 VDC 0.39 A, 24 VDC 0.09 A
External 24 VDC supply for inputs 24 VDC, 300 mA (do not use to drive output devices)
Expansion Up to 3 cp1w-series expansion i/o units or expansion units; maximum I/O points 160
Dimensions (H × D × W) 90 × 80 × 150 mm (110 mm height with mounting brackets)
Weight 640 g max.
Operating temperature / humidity -20 to 60 °C; 10% to 90%, no corrosive gas
Terminal block Fixed, M3 screws
Standards listed in datasheet EC Directives, KC and UL
Relay output rating 2 A at 250 VAC (cosφ = 1) or 2 A at 24 VDC, 4 A per common; minimum load 10 mA at 5 VDC
Communications Two built-in Ethernet ports with switching hub (100BASE-TX / 10BASE-T), USB B-type port; serial ports through option boards

How the CP2E-N40DR-A works inside a machine

The CP2E-N40DR-A follows the usual Omron micro PLC cycle: it reads the 24 DC inputs, executes the ladder program, and writes the 16 outputs, a method the datasheet describes as cyclic scan with immediate refreshing. Ladder diagram is the base language, and function blocks written in ladder or structured text let you package repeated logic such as a motor starter or a valve sequence once and reuse it. The datasheet gives a limit of 64 function block definitions and 128 instances.

Because the CP2E-N40DR-A is a Network-class CPU, it adds an Ethernet connection to the machine. Two ports are built in with a switching hub, so a second device or the next PLC can be daisy-chained without an external switch, and FINS over UDP or TCP lets a SCADA system, an HMI or another Omron controller exchange data with it. The unit also supports four-axis positioning with linear interpolation through pulse outputs on the transistor versions; on a relay model such as this one, pulse outputs are not available, so positioning needs a transistor-output CPU.

Inputs are 24 VDC. The first inputs on the unit double as high-speed counter or interrupt inputs (response 2.5 µs min. on the fastest group and 50 µs on the interrupt group), while the remaining inputs are normal inputs with an adjustable filter of 0 to 32 ms (default 8 ms). That split matters when you assign signals, because a proximity sensor feeding a tachometer should land on a counter input, not a normal one.

Options, expansion and related models for the CP2E-N40DR-A

Capacity can grow with CP1W-series Expansion I/O Units and Expansion Units, up to three in total on the CP2E-N40DR-A, to a maximum of 160 I/O points. Analog, temperature and additional digital modules come from that expansion family. Option boards add communication or analog channels: CP1W-CIF01 (RS-232C), CP1W-CIF11 and CP1W-CIF12-V1 (RS-422A/485) and, for N-class units, CP2W-CIFD1, CIFD2 and CIFD3 two-port boards on slot 1; analog option boards are CP1W-ADB21, CP1W-DAB21V and CP1W-MAB221.

Sibling models in this lineup include CP2E-N30DR-A, CP2E-N60DR-A, CP2E-N20DR-A, CP2E-N30DT-D, CP2E-S30DR-A, CP2E-S40DR-A. They share the programming environment but differ in class, I/O count and supply. A battery (CP2W-BAT02) is only needed for the clock function and cannot be fitted to Essential units; data and program are otherwise kept without a battery.

Selection and ordering checklist for CP2E-N40DR-A

  • Confirm the control voltage: the CP2E-N40DR-A is 100 to 240 VAC; a DC or AC mismatch is the most common ordering error.
  • Count real signals: 24 inputs and 16 outputs, then add a margin of about 15% for future changes.
  • Decide relay versus transistor outputs from the load: relays suit mixed AC and DC loads at up to 2 A, transistors suit fast switching and 24 VDC loads.
  • Check whether Ethernet, serial or both are needed: class N has Ethernet, S and E have serial only.
  • Confirm programming software: CX-One and CX-Programmer are used to program the CP2E; ask for the software version required for your CPU.
  • Agree whether the project needs a clock (battery CP2W-BAT02 on N and S classes).

Installing and commissioning the CP2E-N40DR-A

Mount the CP2E-N40DR-A on a DIN rail or with its brackets inside a ventilated panel, keeping the space above and below for airflow. Wire the supply (100 to 240 VAC) first, check polarity or phase and the earth connection, and ground the unit to 100 Ω or less as the datasheet requires. Keep 24 VDC signal cables away from power cabling; the datasheet quotes noise immunity of 2 kV on the power line, but good routing prevents most nuisance trips.

Terminals are fixed M3 screw terminals, so tighten them evenly and recheck after the first thermal cycles. Connect a PC through the USB port to transfer the program, set the PLC setup values (input filter, communication parameters), then test outputs one at a time in a safe mode before running the machine.

Maintenance, diagnostics and spares

Each input and output terminal has an LED, which shortens fault finding: a lit input LED with no ladder response points to wiring or the PLC setup, while a missing output LED points to the program. Relay outputs have a rated electrical life of 200,000 operations for a resistive 24 VDC load and 70,000 for an inductive 250 VAC load, so a spare CPU or a set of expansion output units is useful for machines that cycle often. For critical lines, keep a backed-up copy of the project file and a spare CP2E-N40DR-A with the same supply code.

Typical applications of the CP2E-N40DR-A in Oman and the GCC

In Oman and across the GCC, the CP2E-N40DR-A fits small and mid-size machines rather than plant-wide control: water treatment dosing skids, desalination auxiliary panels, pump and tank logic, packaging and conveying lines, workshop machines and HVAC control. The datasheet allows operation from -20 to 60 °C, which helps in outdoor kiosks and unconditioned switch rooms in summer, but panels in direct sun should still be shaded and ventilated, and dusty sites should use sealed enclosures with filters.

For oil and gas sites the CP2E-N40DR-A is generally used for non-critical auxiliary tasks, such as utility skids and package-unit control, while safety and emergency shutdown functions stay on dedicated safety systems.

Information to send with an RFQ for CP2E-N40DR-A

  • Exact part number CP2E-N40DR-A and quantity, including any spare units.
  • Required delivery location (Muscat, Sohar, Salalah, GCC) and target date.
  • Whether the CPU is for a new machine or a like-for-like replacement, and the existing CPU label photo if replacing.
  • Expansion units, option boards, battery and cables needed with the CPU.
  • Any documents you need with the quotation, such as datasheet or compliance statements.

Documents and quotation

A datasheet for the CP2E family is attached on this page, covering the CP2E-N40DR-A ordering information, general and performance specifications, I/O ratings and dimensions. Please read the datasheet footnotes before finalising the I/O assignment.

To request a quotation, send the part number CP2E-N40DR-A, quantity and delivery location. Seven Star LLC will confirm availability and lead time from our base in Muscat.

Other Models in the Omron Cp2e Cpu Range

Seven Star LLC supplies models from the Omron Cp2e Cpu range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Omron CP2E-N30DR-A CP2E 30-Point N-Type CPU UnitPLC & I/O CardsView details
Omron CP2E-N40DR-A CP2E 40-Point N-Type CPU UnitPLC & I/O CardsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Omron CP2E-N40DR-A Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Omron is a Japanese electronics and automation company, founded in 1933 in Osaka by Kazuma Tateisi and now headquartered in Kyoto. Its industrial automation business makes PLCs, I/O, sensors, relays, safety components, motion control and robots. Omron's CJ and NX series controllers and I/O units are widely used in machine building.

Seven Star LLC lists Omron PLC input and output units from the CJ and NX series and supplies them to panel builders and maintenance teams in Oman.

Omron company profile

Founded 1933, Osaka, Japan
Founder Kazuma Tateisi
Headquarters Kyoto, Japan
Business Industrial automation, healthcare, electronic components
Product families CJ1/CJ2 PLCs and I/O units, NX and NJ controllers, NX I/O, E2E proximity sensors, G2R and MY relays

Omron CJ-series and NX-series units listed here

Three I/O units are on this page. The CJ1W-ID211 is a CJ-series 16-point 24 VDC input unit and the CJ1W-OC211 is a CJ-series 16-point relay output unit. The NX-ID5442 is an NX-series 16-point 24 VDC digital input unit for PNP wiring, 12 mm wide with push-in terminals. CJ and NX units belong to different hardware platforms and do not plug into each other's racks.

Omron products we list

Family Examples
PLC & I/O Cards CJ1W-ID211 CJ-Series 16-Point 24 VDC Inp…, CJ1W-OC211 CJ-Series 16-Point Relay Outp…, NX-ID5442 NX-Series 16-Point Digital Inp…

Ordering Omron PLC modules: what we need

Send the complete model number from the front or side label of the unit, including every suffix. If you are replacing a failed card, add the CPU or coupler model it is mounted with, and tell us if the terminal block or connector is needed as well. For obsolete Omron PLC parts we check which successor the manufacturer documents. Requests from other GCC countries are handled the same way.

Facts checked against Omron's published company history, October 2026.

FAQ

Questions about the Omron CP2E-N40DR-A CP2E 40-Point N-Type CPU Unit

Answers from our engineering team on installation, compatibility and integration.

01What does the CP2E-N40DR-A part number mean?
CP2E is the family, N is the network model class, 40 is the number of built-in I/O points, D means DC inputs, R is the output type (relay outputs) and A indicates 100 to 240 VAC power supply.
02How many I/O points does the CP2E-N40DR-A have?
It has 40 built-in points, 24 inputs and 16 outputs. With up to three CP1W expansion units the system can reach 160 points.
03Does the CP2E-N40DR-A have Ethernet?
Yes. Network-class units have two built-in Ethernet ports with a switching hub, which support FINS/UDP and FINS/TCP among other protocols.
04What supply does the CP2E-N40DR-A need?
It runs on 100 to 240 VAC. The operating range is 85 to 264 VAC and a 24 VDC 300 mA output is provided for input devices.
05What software is used to program the CP2E-N40DR-A?
CX-One with CX-Programmer is used to program CP2E units, over the USB port. Function blocks can be written in ladder diagram or structured text.