Brand: Danfoss
Danfoss 148B4751 SVA-S SS 25 Stainless Stop Valve, Socket Weld
Description
SVA-S SS 25: a stainless-steel stop valve with socket-weld ends
The 148B4751 is an SVA-S SS 25 shut-off valve made in stainless steel, with 25 mm (1 in) socket-weld connections to ASME B 16.11. Body and connection material are both stainless steel, the neck is standard, and a protective cap replaces the handwheel. Net weight is 3.619 kg.
The ratings printed are a Kv of 24.8 m3/h, a maximum working pressure of 52 bar (754 psig) and a temperature range of -60 to 150 C. The page lists CE, EAC and UA approvals. The valve is bi-flow and has an embossed arrow.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 148B4751 |
| Type | SVA-S SS 25 |
| Approvals as listed | CE; EAC; UA |
| Body material | Stainless steel |
| Connection standard | ASME B 16.11 |
| Inlet connection size | 1 in / 25 mm |
| Inlet connection type | Socket Weld |
| Kv value | 24.8 m3/h |
| Maximum working pressure | 52 bar |
| Outlet connection size | 1 in / 25 mm |
| Outlet connection type | Socket weld |
| Refrigerants | R113; R114; R1150; R1234yf; R1234ze(E); R125; R1270; R1336mzz(Z); R134a; R152a; and others listed in the data sheet |
| Temperature range | -60 C to 150 C |
| Net weight | 3.619 kg |
| EAN | 5715162457771 |
Stainless steel where carbon steel is not enough
Stainless bodies are chosen for aggressive atmospheres such as coastal or washdown areas, and for low-temperature service where the design code asks for a material with proven toughness. The SS series has its own data sheet, separate from the carbon-steel SVA-S/L data sheet, so the right document is attached here.
Socket-weld connections with ASME B 16.11 dimensions suit US-style pipe specifications and small-bore pipework, and differ from the EN 10220 butt-weld codes used for the carbon-steel valves in the same range. The two are not interchangeable without changing the pipe preparation.
Checks before ordering
Match connection standard, wall thickness and pipe material to the plant specification, and confirm refrigerant compatibility from the data sheet. Weld with an approved stainless procedure and keep heat away from the seat; the installation guide for SVA-S/L SS 15-150 describes the sequence.
Spare parts are listed for the SVL Flexline platform. Confirm whether a handwheel or cap is wanted, since the equipment is part of the code. Confirm also that 52 bar suits your test pressure.
Document the weld procedure and filler used for the stainless socket welds, since inspectors for pressure systems normally ask for the qualification record of the joint as well as the valve data.
Other types and sizes from the same Danfoss family that appear in the Danfoss store listing include SVA-S 65 (148B4931), SVA-S 6-10 (148B5013), SVA-S 15-20 (148B5276), SVA-S 25-40 (148B5476), SVA-S 50 (148B5728), SVA-S 80 (148B5916), SVA-S 100 (148B6012), SVA-S 125 (148B6116). These are listed for orientation only; each has its own datasheet values, so check size, connection and version before ordering.
Documents and quotation
The attached file is the Danfoss Shut-off valve, type SVA-S SS and SVA-L SS AI234986440234en-001101 (manufacturer, unaltered). It is the manufacturer’s own PDF, hosted here unaltered. Related items sit under globe and stop valves. Seven Star LLC is an independent supplier in Muscat; send the code 148B4751 with the quantity and we will quote.
Datasheets & Documents
- Datasheet Danfoss Shut-off valve, type SVA-S SS and SVA-L SS AI234986440234en-001101 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
An SVA-S SS 25 stainless-steel stop valve with 25 mm socket-weld connections to ASME B 16.11.
Yes, both body and connection material are stainless steel according to the product page.
52 bar (754 psig) and -60 to 150 C.
24.8 m3/h.
The Danfoss SVA-S SS and SVA-L SS data sheet AI234986440234en-001101.