Brand:

SICK MICS3-CBAZ40PZ1P01 microScan3 Safety Laser Scanner

Description

MICS3-CBAZ40PZ1P01 is a SICK microScan3 safety laser scanner (part no. 1092720) that monitors a protective field on the floor plane and switches a safe output when a person or object enters it. The catalogue summary lists: product version: microScan3 Pro – PROFINET; integration in the control system: PROFINET PROFIsafe; protective field range: 4 m; scanning angle: 275°; number of fields: 128.

How the MICS3-CBAZ40PZ1P01 works and where it fits

A safety laser scanner sweeps a pulsed infrared laser through its scanning angle and measures the time of flight of each reflection. When the field is violated the scanner signals the safe state to the machine control.

Safety laser scanners protect from one side only and without a sender and receiver pair, which makes them practical on mobile platforms and in cells where light curtains would be in the way. In mobile use the scanner must be mounted so that its field covers the full width of the vehicle plus an allowance for the stopping distance at the highest speed.

Technical specifications

Parameter Specification
Type code MICS3-CBAZ40PZ1P01
Part number 1092720
Product family microScan3
Product version microScan3 Pro – PROFINET
Application Indoor
Protective field range 4 m
Warning field range 40 m
Number of simultaneously monitored fields ≤ 8
Number of fields 128
Number of monitoring cases 128
Scanning angle 275°
Resolution (can be configured) 30 mm; 40 mm; 50 mm; 70 mm; 150 mm; 200 mm
Angular resolution 0.39°
Response time 95 ms
Protective field supplement 65 mm
Type Type 3 (IEC 61496)
Safety integrity level SIL 2 (IEC 61508)
Category Category 3 (EN ISO 13849)
Performance level PL d (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 8.0 x 10⁻⁸
Conformities Conformance Class C
Restart interlock Yes
Multiple sampling Yes
Monitoring case switching Yes
Simultaneous monitoring Yes
Static protective field switching Yes
Safe contour detection Yes
Contour as a reference Yes
Integrated configuration memory Yes
Measured data output Via Ethernet
Declarations and certificates in the data sheet EU declaration of conformity; UK declaration of conformity; ACMA declaration of conformity; China RoHS; cULus certificate; S Mark certificate; Profinet certificate; PROFIsafe certificate; EC-Type-Examination approval; China GB certificate; PROFIenergy certificate; Information according to Art. 3 of Data Act (Regulation EU 2023/2854)

Type code MICS3-CBAZ40PZ1P01 and what to check before ordering

Derived from the listed angles: a 275 degree sector at 0.39 degree angular resolution corresponds to roughly 706 measuring points per scan. This is a derived value for orientation.

Wiring data to note: power draw 7.2 W; supply 24 V DC (16.8 V DC … 30 V DC); resolution 30 mm; 40 mm; 50 mm; 70 mm; 150 mm; 200 mm; connection 1 x male connector, M12, 4-pin, A-coded; interface 2 x M12 female connectors, 4-pin, D-coded; response time 95 ms; range 4 m.

Housing and environmental limits listed: housing: Aluminum; light source: pulsed laser diode; storage temperature: –25 °C … +70 °C; wavelength: 845 nm; weight: 1.45 kg; operating temperature: –10 °C … +50 °C; enclosure rating: IP65 (IEC 60529); dimensions: 112 mm x 150.7 mm x 111.1 mm (without system plug).

Reflective surfaces and heavy dust on the cover are typical causes of nuisance stops.

Keep the configuration file and its checksum with the machine documentation, since replacing a scanner then becomes a controlled upload instead of a re-design.

Documents and quotation

Attached to this page: the SICK data sheet for MICS3-CBAZ40PZ1P01, part no. 1092720, as published by SICK. Send the type code, quantity and delivery location through the RFQ form and Seven Star LLC, an independent supplier in Muscat, will respond with a quotation. Similar products sit under Safety Switches & Guard Locking. Confirm the full code against the device it replaces; if this page and the data sheet ever disagree, follow the data sheet.

Datasheets & Documents
  • PDF Data Sheet SICK MICS3-CBAZ40PZ1P01 official data sheet (part no. 1092720) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Facts checked against SICK's published company history and annual figures, October 2026.

Frequently Asked Questions

What is the SICK MICS3-CBAZ40PZ1P01?
It is a SICK safety laser scanner (microScan3), part no. 1092720. The catalogue summary reads: Product version: microScan3 Pro - PROFINET; Integration in the control system: PROFINET PROFIsafe; Protective field range: 4 m; Scanning angle: 275°.
What supply does the MICS3-CBAZ40PZ1P01 need?
Supply voltage is 24 V DC (16.8 V DC ... 30 V DC). Performance level: PL d (EN ISO 13849).
What protection rating and temperature range are given?
Enclosure rating: IP65 (IEC 60529). Ambient operating temperature: –10 °C ... +50 °C. Confirm both against the site before ordering.
Does the page include the data sheet?
Yes. The official SICK data sheet for part no. 1092720 is attached as a PDF and linked on this page; where it differs from the page text, the data sheet applies.
What should be confirmed before ordering the MICS3-CBAZ40PZ1P01?
Compare the full type code and part number 1092720 with the device being replaced, check supply, output or interface and mounting, and send the details through the RFQ form. Seven Star LLC is an independent supplier, not a SICK partner.