Chromalox CWM Constant-Wattage Heat Trace Cable

Description

Constant-wattage heat trace cable for process temperatures up to 350 °F

The Chromalox CWM is a parallel constant-wattage heat trace cable for process temperature maintenance and freeze protection where a given watt density is needed at all times. A nickel-chromium heating wire wound over a pairing jacket gives uniform output over the whole length, from a few feet to 780 ft (238 m) from a single power point, with no in-rush current at start-up. The cable can be cut to length and spliced in the field, and its fluoropolymer jacketing suits chemically hostile environments.

Because output is constant it suits higher-temperature applications that need higher watt densities, and the sheet notes that it is not suited for overlapping. Cable jacket colours identify each wattage and voltage code, and an extensive range of wattages and voltages is available.

Technical specifications

Parameter Specification
Series CWM constant-wattage medium-temperature heating cable
Construction Two 12 AWG copper bus wires in FEP jackets, paired in a pairing jacket carrying nickel-chromium heating wire; FEP insulation, tinned copper braid and FEP overjacket
Voltage supply 120 VAC, 208 to 277 VAC (240 VAC nominal) or 480 VAC depending on model
Maximum maintenance temperature 350 deg F (177 °C); 392 deg F (200 °C) maximum exposure with power off; minimum installation -40 deg F (-40 °C)
Maximum pipe maintenance temperature (power on) From 340 deg F (171 °C) at 3 W/ft down to 200 deg F (93 °C) at 12 W/ft without AT-1 tape; 350 to 296 deg F (177 to 147 °C) with AT-1 tape
Trace surface Metal
Cable size and weight 0.356 × 0.246 in (9.0 × 6.2 mm); 110 lb per 1,000 ft (50 kg per 300 m); maximum bend radius 1.125 in (28.5 mm)
Approvals Ordinary areas; Class I, Division 2, Groups B, C, D; Class II, Division 2, Groups E, F, G; Class III; T3 (392 deg F / 200 °C), with surface limits stated for Class II Div. 2 Groups F and G
Ground fault Ground fault protection required; minimum trip level of 30 mA recommended

Models, output and circuit length

Model Volts Output at 50 °F Jacket colour Max. circuit length PCN
CWM 4-1CT 120 4 W/ft (13 W/m) Blue 350 ft (159 m) 392075
CWM 8-1CT 120 8 W/ft (26 W/m) Orange 240 ft (109 m) 392163
CWM 12-1CT 120 12 W/ft (39 W/m) Black 200 ft (91 m) 392251
CWM 4-2CT 240 4 W/ft (13 W/m) Green 700 ft (318 m) 392083
CWM 8-2CT 240 8 W/ft (26 W/m) Yellow 480 ft (218 m) 392171
CWM 12-2CT 240 12 W/ft (39 W/m) White 400 ft (181 m) 392260
CWM 12-4CT 480 12 W/ft (39 W/m) Green 780 ft (354 m) 392278

Alternate-voltage output is also published: for example the CWM 12-2 delivers 9.0 W/ft at 208 V and 16.0 W/ft at 277 V, and the CWM 12-4 delivers 2.3 W/ft at 208 V. Always take the output at the actual supply voltage from the sheet before designing a circuit.

Design, accessories and ordering checks

Chromalox points designers to its ChromaTrace project design software, the Heat Trace Design Guide (PJ130), the Pipe Heat Tracing Design Worksheet (PJ305) and the Industrial Heating Cable Installation Instructions (PJ438). Power connection, splice and tee, end seal, ambient-sensing and line-sensing thermostat accessories are available in the U Series, DL Series and EL Series, and Chromalox advises using only its own accessories to keep performance, warranty and approvals valid. A thermostat or controller such as the controllers listed on this site is needed to hold the pipe temperature.

Before ordering confirm the pipe material and size, insulation, the maintenance temperature and the maximum exposure temperature, supply voltage, circuit length against the table, the area classification and the ground fault protection arrangement. The cable is a heating product and the design must be calculated for each pipe run.

How the Chromalox CWM works

Two copper bus wires run along the cable. A nickel-chromium heating wire is wound over the pairing jacket and touches the bus wires at set points. Current flows through each short section and gives heat. The output stays constant along the length.

Where the CWM is used

  • Process temperature maintenance
  • Freeze protection
  • Pipes needing higher watt density
  • Chemically hostile areas
  • Metal pipes and vessels

Selection checklist for the CWM

  • Maintenance temperature
  • Watt density
  • Supply voltage
  • Circuit length
  • Pipe material
  • Insulation thickness
  • Ground fault protection
  • Cut-to-length need

Installation, commissioning and maintenance notes for the CWM

Do not overlap the cable. Fix it to the pipe with tape along its length. Make the power connection and end seal with the right kit. Fit ground fault protection. Test the insulation resistance before and after the thermal insulation is fitted.

Requesting a quotation for the Chromalox CWM

Please send the pipe size, the temperature to hold and the voltage. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

CWM cable type

It is a parallel constant-wattage heat trace cable.

CWM length

A single power point can feed up to 780 ft or 238 m.

CWM start-up

There is no in-rush current at start-up.

CWM field work

The cable can be cut to length and spliced in the field.

CWM jacket

The fluoropolymer jacket suits chemically hostile areas.

CWM overlap

The cable is not suited for overlapping.

CWM jacket colours

The jacket colour shows the wattage and voltage code.

CWM bus wires

It has two 12 AWG copper bus wires.

CWM insulation

The insulation is FEP with a tinned copper braid.

CWM supply voltage

The supply is 120 V, 208 to 277 V or 480 V by model.

CWM maintenance temperature

The maximum maintenance temperature is 350 degrees F.

CWM exposure temperature

The maximum exposure with power off is 392 degrees F.

CWM installation temperature

The minimum installation temperature is minus 40 degrees F.

CWM cable size

The cable is 9.0 x 6.2 mm.

CWM bend radius

The maximum bend radius is 28.5 mm.

CWM ground fault

Ground fault protection with a 30 mA trip level is recommended.

CWM models

Models include CWM 4-1CT, 8-1CT and 12-1CT at 120 V.

Cable records for the CWM

Record the circuit length, the insulation resistance and the date.

Choosing the right CWM output

Choose the output from the pipe size and the temperature to hold.

Documents and quotation

The Chromalox CWM data sheet (EHT-DS-CWM) is attached. Seven Star LLC, an independent supplier in Muscat, quotes by model code, voltage and length; stock and lead time are confirmed at quotation.

Datasheets & Documents
  • PDF Datasheet Chromalox CWM Constant-Wattage Medium-Temperature Heating Cable data sheet EHT-DS-CWM (English) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Chromalox is an American manufacturer of electric process heating, heat trace and thermal control products. The company was founded in 1917 by Edwin L. Wiegand and, according to its website, is today part of Spirax Group. Its catalog spans immersion and circulation heaters, tubular and strip heaters, heat trace cables and controls, and temperature and power controllers.

Industrial heaters and heat trace

The industrial range covers screw plug and flanged immersion heaters, over-the-side heaters, air and radiant heaters, steam generators and packaged process heating systems. Heat trace products include constant wattage, self-regulating and mineral-insulated cables, with thermostats, controllers and connection kits for freeze protection and process temperature maintenance.

Controls and requesting a quote

Controllers run from single-loop temperature and process controllers to SCR power controllers and heat trace controllers. Seven Star LLC, an independent supplier in Muscat, lists selected Chromalox models for projects in Oman and the GCC. Send the full model code, voltage, kW or wattage and the fluid or application, and we will prepare a quotation from the Chromalox data sheet.

Frequently Asked Questions

What is the maximum maintenance temperature of CWM cable?
The sheet gives a maximum maintenance temperature of 350 F (177 C) and a maximum exposure temperature of 392 F (200 C) with power off.
What is the longest circuit length?
The CWM 12-4 on 480 V is listed for up to 780 ft (354 m); circuit length depends on the model, voltage and nominal output.
Can CWM cable be cut and spliced in the field?
Yes. The cable can be cut to length and spliced in the field using Chromalox connection kits, but it is not suited for overlapping.
Which hazardous area approvals are listed?
Ordinary areas, Class I Division 2 Groups B, C, D, Class II Division 2 Groups E, F, G and Class III, with a T3 temperature rating as printed.
Is ground fault protection required?
Yes. The sheet states a ground fault protection device is required, with a minimum trip level of 30 mA recommended.