ebm-papst AC 100 MR EC Axial Panel Fan Wide Input 3.8 W
Description
Overview
The ebm-papst AC 100 MR is an EC axial panel fan with a cylindrical housing, listed by the manufacturer with dimensions of 98.50 x 130 mm and a weight of 0.40 kg. It is an electronically commutated fan that accepts a wide input range of 85 to 265, shown on the datasheet at a frequency of 50/60 Hz, and it consumes only 3.8 W. Instead of a single fixed operating point, the datasheet gives ranges: an air flow of 55 to 90 m3/h, a sound power level of 4.5 to 5.0 B and a sound pressure level of 33 to 40 dB(A). The range reflects the fact that the speed of this fan is controllable, so one unit can be set to suit a quiet low-flow condition or a stronger cooling condition.
Seven Star LLC is an independent supplier serving Oman and the GCC. This page explains what the figures on the datasheet mean for a buyer who wants to replace or specify the fan.
EC technology in a small tube fan
Electronic commutation replaces the brushes and the shaded-pole winding of a traditional AC fan with a controller built into the motor. The benefits are low power consumption, a long calculated life and the ability to work from a wide range of supplies. The datasheet quotes an L10 life of 70,000 h at 40 degrees Celsius and 50,000 h at the maximum ambient temperature of 55 degrees Celsius, with a minimum of minus 10 degrees Celsius. Both figures are higher than those of the small AC panel fans on our site, which typically show 40,000 to 60,000 h at 40 degrees Celsius.
Power consumption of 3.8 W is also very low. A conventional AC fan of similar size would use 9 to 18 W, so replacing several of them in a large installation can cut the electricity use and the heat added to the enclosure. The airflow enters over the struts, which matters when you lay out the air path.
Datasheet values for ebm-papst AC 100 MR
| Item | Value |
|---|---|
| Type | EC axial panel fan |
| Input range | 85 to 265 (listed as VDC on the datasheet) |
| Frequency | 50/60 Hz |
| Power consumption | 3.8 W |
| Air flow | 55 to 90 m3/h |
| Sound power level | 4.5 to 5.0 B |
| Sound pressure level | 33 to 40 dB(A) |
| Ambient range | minus 10 to 55 degrees Celsius |
| Dimensions | 98.50 x 130 mm |
| Weight | 0.40 kg |
| Airflow direction | Intake over struts |
| L10 life at 40 degrees Celsius | 70,000 h |
| L10 life at maximum temperature | 50,000 h |
How ebm-papst AC 100 MR differs from the AC 100 NR
The AC 100 series includes more than one variant, and the datasheet of the NR type lists the same weight, dimensions, airflow direction and L10 values but gives no nominal electrical data on its first page. For this reason we describe the MR type only from the datasheet that shows its input range, power consumption and flow range. If you need the NR variant, ask us to check the manufacturer data for that number separately instead of assuming the same electrical values.
Where it is used in Oman and the GCC
Inline tube fans of this size are used to extract air from small enclosures, to ventilate battery compartments, to pull cool air through filter housings and to cool compact power electronics. Because the input range covers both 110 to 120 and 220 to 240 mains, the same fan can be stocked for equipment imported from different regions.
Estimating flow and speed setting
The lower end of the flow range, 55 m3/h, corresponds to about 0.0153 m3/s, which removes roughly 18 W for each kelvin of air temperature rise. At the upper end, 90 m3/h, the figure is about 30 W per kelvin. Select the operating condition so that the heat load of the enclosure is covered with margin, and check how the speed is set in your equipment, since the datasheet does not describe a control interface and the speed adjustment method must be confirmed for the version you order.
Energy and running cost over a year
A fan that runs around the clock accumulates 8,760 operating hours in a year. At 3.8 W, that is about 33 kWh per fan per year. A conventional AC fan drawing 14 W over the same period uses about 123 kWh, so each EC replacement saves close to 90 kWh. In a plant with dozens of cabinets, the saving is not only in the electricity bill: every watt not dissipated by the fan is a watt that does not have to be removed from the cabinet by air conditioning. This is a practical reason why EC fans are specified for new panels in warm climates, even though the purchase cost per fan is higher than for a simple shaded-pole unit.
When you evaluate the payback, include the longer life as well. A calculated L10 of 70,000 h at 40 degrees Celsius is about eight years of continuous operation, which reduces the number of cabinet openings and the risk of an unplanned stop caused by a fan failure.
Mounting
Because the housing is cylindrical, the fan is fixed through a round opening or in a duct, not on a square flange. Confirm the diameter of 98.50 mm against your opening and keep the inlet free of obstructions that would raise noise.
Servicing
The fan has no brushes, so maintenance is limited to cleaning the blades and checking the cable. Replace the unit if the speed becomes unstable or the noise changes.
Ordering notes
Quote the full designation and the quantity. If the replacement must match a specific electrical connection, send a photograph of the old fan and its label.
Related items you may also need: ebm-papst R1G225-AF11-52 DC Fan | ebm-papst 4650 N AC Axial Compact Fan 119 mm 230 V | ebm-papst R1G175-AB41-02 DC Fan | All ebm-papst products.
Before you order the ebm-papst AC 100 MR
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the ebm-papst AC 100 MR code on this page.
- The quotation for the ebm-papst AC 100 MR states the confirmed code, the condition of the unit and the lead time to site.
- The attached manufacturer datasheet covers the ebm-papst AC 100 MR ratings, dimensions and installation details.
- Delivery of the ebm-papst AC 100 MR is arranged to project sites in Oman and across the GCC, alongside the rest of our industrial fans & blowers range.
- A spare ebm-papst AC 100 MR on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The manufacturer datasheet for this fan is attached to this page. To receive a quotation, send an RFQ with the part number ebm-papst AC 100 MR, the quantity, your delivery location in Oman or the GCC and any project reference, and we will respond with availability and lead time.
Datasheets & Documents
- Datasheet ebm-papst AC 100 MR EC Axial Panel Fan Wide Input 3.8 W Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ebm-papst is a German family-owned maker of fans and motors, headquartered in Mulfingen. It was founded in 1963 by Gerhard Sturm and Heinz Ziehl as Elektrobau Mulfingen (ebm) and took its current name after acquiring Papst in 1992. ebm-papst makes EC fans, blowers and motors for ventilation, cooling and air conditioning.
Seven Star LLC is an independent supplier in Muscat. We list ebm-papst fans for equipment cooling in Oman and the GCC.
ebm-papst company profile
| Founded | 1963, Mulfingen, Germany |
|---|---|
| Founders | Gerhard Sturm and Heinz Ziehl |
| Headquarters | Mulfingen, Germany |
| Ownership | Family-owned |
| Product families | RadiCal and R1G EC centrifugal fans, axial fans, compact DC fans, EC motors |
Milestones
- 1963: Elektrobau Mulfingen is founded.
- 1992: ebm acquires Papst and becomes ebm-papst.
ebm-papst product series
Centrifugal fans include the R1G175-AB41-02 and R1G225-AF11-52 DC fans with backward curved impellers. Papst industrial cooling fans are used in cabinets and electronics.
Replacements should match the part number exactly, as size, voltage, airflow, speed signal and connector can differ between versions. EC fans can be speed controlled to save energy and reduce noise.
Where ebm-papst fans are used
Cooling of drives, UPS, telecom and control cabinets, HVAC units and electronic equipment.
ebm-papst products we list
| Family | Examples |
|---|---|
| Cooling | R1G175-AB41-02 DC Fan, R1G225-AF11-52 DC Fan |
| Automation Accessories | Papst Industrial Cooling Fan |
Ordering ebm-papst fans: what we need
Send the full part number from the label, voltage and quantity.
Facts checked against ebm-papst's published company history, October 2026.
Browse ebm-papst products by category: Cooling, Automation Accessories.
FAQ
Questions about the ebm-papst AC 100 MR EC Axial Panel Fan Wide Input
Answers from our engineering team on installation, compatibility and integration.
01What input range does the ebm-papst AC 100 MR accept?
The datasheet lists a wide input range of 85 to 265 at 50/60 Hz, so one version covers both 110 to 120 and 220 to 240 mains.
02How much power does the ebm-papst AC 100 MR use?
It draws only 3.8 W, which is much less than a conventional AC fan of similar size.
03What air flow does the ebm-papst AC 100 MR give?
The datasheet gives a range of 55 to 90 m3/h with sound power of 4.5 to 5.0 B and sound pressure of 33 to 40 dB(A).
04What is the service life of the ebm-papst AC 100 MR?
The calculated L10 life is 70,000 h at 40 degrees Celsius and 50,000 h at the maximum ambient temperature of 55 degrees Celsius.
05What size is the ebm-papst AC 100 MR?
The datasheet lists dimensions of 98.50 x 130 mm and a weight of 0.40 kg, with intake over the struts.