Brand:

Pizzato CS AR-06V024 Safety Module with Monitored Start

Description

Overview

A start button that sticks or is taped down is one of the classic ways to defeat a safety relay. Monitored start closes that loophole: the relay only restarts if it saw the button open first. The Pizzato CS AR-06V024 is the monitored-start version of the Pizzato CS AR-05 and AR-06 pair. It watches emergency stops, guard end positions, magnetic safety sensors and OSSD semiconductor outputs on one or two channels and closes three normally open safety contacts, with one normally closed contact for signalling. Safety limits are SIL 3, PL e and category 4. The supply is 24 V ac/dc and the terminals are screw type. Seven Star LLC is an independent supplier serving Oman and the GCC.

What monitored start does

With manual start, pressing the button is enough to close the relay. With monitored start, the module also examines the start circuit, so that a button that is stuck, taped down or bridged by a wire cannot make the machine restart on its own. For this reason the code 06 is chosen for emergency stop circuits and for guards where a restart must be a deliberate act by a person. The catalogue lists the start configuration of the CS AR-06 as monitored only, while manual and automatic start belong to the AR-05. In the input diagrams the manufacturer tells the user to take the circuit diagrams for manual start and to use the AR-06 module with them, so the reset button is wired exactly as for the manual start version.

The practical benefit appears during maintenance. A technician who has tied the reset button down to speed up testing will find that the machine does not restart, because the module sees the start circuit already closed. Auditors like this behaviour because it can be demonstrated in a few seconds, and because the design needs no extra relay or software to prove it.

Data table for Pizzato CS AR-06V024

Parameter Value
Start mode Monitored start only (code 06)
Inputs 1 or 2 channels: contacts, magnetic sensors, OSSD outputs
Outputs 3NO safety, 1NC signalling
Safety limits SIL 3, PL e, category 4
Supply 24 Vac/dc, 50 to 60 Hz, minus 10 to plus 15 percent
Power consumption Below 5 VA ac, below 2 W dc
Response time Below 300 ms
Release time Below 15 ms; below 70 ms without supply
Start impulse Over 250 ms
Simultaneity time Unlimited
Contact ratings AC-15 3 A at 230 V; DC-13 4 A at 24 V; Ith 6 A; 64 A2
Fuse 4 A external
Housing PA 66 V0, IP40, terminals IP20
Ambient Minus 25 to plus 55 degrees Celsius

Why the Pizzato CS AR-06V024 is not the same as the AR-05

Electrically the AR-05 and AR-06 share the same data table. The difference sits in the start logic. The AR-05 offers manual or automatic start, including a version where the start terminals are bridged so the relay re-energises on its own. The AR-06 cannot be bridged in that way. Compared with the CS AR-04, which allows all three start modes in one module but works only with contacts and magnetic sensors, the AR-06 sacrifices flexibility for the monitored start together with OSSD inputs and a fixed behaviour that is easy to explain to auditors.

Applications in Oman and the GCC

Emergency stop circuits in processing plants, restart after a guard opening in packaging lines, and reset functions on cells with light curtains are the usual places. Where a plant standard demands a stuck-button check on every reset, standardising on this code simplifies the drawings. It is also used on test benches in training centres and technical colleges.

Wiring and testing

  1. Wire the emergency stop or guard contacts to the input channels, with OSSD outputs if used.
  2. Connect the reset button as in the manual start diagrams of the catalogue, since the AR-06 uses those circuits.
  3. Apply 24 V ac/dc and confirm that the module does not start by itself.
  4. Press the reset button for longer than the minimum start impulse of 250 ms and confirm that the three outputs close.
  5. Hold the button down while closing the inputs and confirm that the module does not start.

Inputs and sensors

The two input channels accept electromechanical contacts, magnetic safety sensors and OSSD semiconductor outputs. The catalogue notes that magnetic safety sensors can only be used in a two-channel configuration, while contacts and OSSD devices may also be used on a single channel, in which case the times tR1, tR, tA and tMIN refer to channel one and to the start input. Opposite potentials may be connected to the two channels, and the cable resistance per input must not exceed 50 ohm. The module’s PTC element protects the supply input, and after a trip it needs more than 3 seconds to reset, so a wiring fault should be removed before the supply is restored.

Selecting among the CS AR modules

When choosing between members of the family, ask three questions. Do the input devices include OSSD outputs? If so, the AR-05 or AR-06 is needed. Must a stuck start button be detected? If so, take the AR-06. Is the shortest possible response needed, with all three start modes available in one module? Then the AR-04 is the better fit. The CS AR-01 offers 2NO plus 1NC, the CS AR-02 offers 3NO, and the CS AR-07 gives 4NO plus 1NC when more safety contacts are needed. Choosing the right module at the design stage avoids rewiring later.

Maintenance

Include the stuck-button test in the periodic checks and replace worn reset buttons. Replace the module if outputs fail to respond. Keep the datasheet with the machine file.

Related items you may also need: Pizzato FR 1007 Position Switch, Adjustable Roller | Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | All Pizzato products.

Points to confirm for the Pizzato CS AR-06V024

  • If the Pizzato CS AR-06V024 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Pizzato CS AR-06V024 request we confirm the exact code, new or surplus condition and lead time in writing.
  • Dimensions, ratings and connection data for the Pizzato CS AR-06V024 are in the datasheet attached to this page.
  • The Pizzato CS AR-06V024 belongs to our safety switches & guard locking range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
  • Plants that run the Pizzato CS AR-06V024 on critical service often hold a spare unit in the store.

Documents and quotation

The catalogue chapter of the CS AR family is attached to this page with technical data and wiring diagrams. To obtain a quotation, send an RFQ with Pizzato CS AR-06V024, the quantity and the delivery destination in Oman or the GCC.

Other Models in the CS AR Range

Seven Star LLC supplies models from the CS AR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pizzato CS AR-04V024 Emergency Stop Safety Module, 3NOSafety Switches & Guard LockingView details
Pizzato CS AR-05V024 Safety Module with OSSD InputsSafety Switches & Guard LockingView details
Pizzato CS AR-06V024 Safety Module with Monitored StartSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pizzato CS AR-06V024 Safety Module with Monitored Start Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS AR-06V024 Safety Module with Monitored

Answers from our engineering team on installation, compatibility and integration.

01What start mode does the Pizzato CS AR-06V024 use?
Monitored start only: the module restarts only if the start button was seen open first and then released.
02How does the CS AR-06V024 differ from the CS AR-05V024?
The data are the same, but the AR-06 has monitored start only, while the AR-05 offers manual or automatic start.
03Does the CS AR-06V024 accept OSSD inputs?
Yes, the catalogue lists contacts, magnetic safety sensors and OSSD semiconductor outputs for the AR-05 and AR-06 modules.
04What outputs does the CS AR-06V024 have?
Three normally open safety contacts and one normally closed signalling contact, rated AC-15 3 A at 230 V.
05What timing does the CS AR-06V024 have?
Response time below 300 ms, release time below 15 ms and below 70 ms without supply, with a start impulse over 250 ms.