Brand:

Pizzato CS AR-05V024 Safety Module with OSSD Inputs

Description

Overview

Modern guard systems rarely consist of plain switches only. Light curtains, coded non-contact sensors and some locking switches report their state through OSSD semiconductor outputs, and the safety relay behind them has to accept those signals as well as ordinary contacts. The Pizzato CS AR-05V024 is built for such mixed circuits. It is a Pizzato safety module that monitors emergency stops, movable guard end positions, magnetic safety sensors and OSSD outputs, and switches three normally open safety contacts with one normally closed signalling contact. The code stands for the manual or automatic start version, a 24 V ac/dc supply and screw terminals. Seven Star LLC is an independent supplier serving Oman and the GCC.

Characteristics of Pizzato CS AR-05V024

Characteristic Value
Start mode (code 05) Manual or automatic start
Input devices Contacts, magnetic safety sensors and OSSD semiconductor outputs
Channels 1 or 2
Output contacts 3NO safety and 1NC signalling, forcibly guided
Safety limits SIL 3, PL e, category 4
Supply (024) 24 Vac/dc, minus 10 to plus 15 percent
Consumption Below 5 VA on ac, below 2 W on dc
Response time tA Below 300 ms
Release time tR1 Below 15 ms; without supply below 70 ms
Minimum start impulse Over 250 ms
Input limits 50 ohm per input, below 30 mA per input
Contact data 230/240 Vac, 300 Vdc; AC-15 3 A at 230 V; DC-13 4 A at 24 V
Thermal current 6 A per branch; 64 A2 total; fuse 4 A
Housing PA 66 V0, IP40, terminals IP20
Temperature Minus 25 to plus 55 degrees Celsius

How Pizzato CS AR-05V024 differs from the AR-04 and AR-06

Compared with the CS AR-04, this module trades speed for versatility: response time is below 300 ms against below 50 ms, the minimum start impulse is over 250 ms against over 100 ms, and release is below 15 ms against below 20 ms. In return it accepts OSSD semiconductor outputs. The CS AR-06 is identical in the data table but has monitored start only, whereas the AR-05 is for manual or automatic start. If your circuit has a start button that must be checked for stuck contacts, take the AR-06 instead. For automatic restart after the guard closes, the AR-05 is the correct member.

Connecting OSSD devices

An OSSD output is a pair of semiconductor outputs that carry test pulses. The catalogue shows an input configuration for OSSD devices from the ST, NS and NG series and from light barriers: the supply and ground of the device come from the 24 V source, the two OSSD outputs go to the two input channels, and the start circuit is wired according to the mode needed. For a single channel the OSSD is connected to one input only. When automatic start is wanted, the start terminals are bridged as the diagram shows. The wiring of a monitored start belongs to the AR-06 code, not to this one.

Using the Pizzato CS AR-05V024 with a light curtain or coded sensor

A light curtain at a robot cell or a coded sensor on a door gives its OSSD signals to the module, which then opens three contacts that feed the drive contactors. The slower response of the module has to be included in the stopping time calculation: the 300 ms response is the time to pull in, while the release is only 15 ms, which is what counts when the beam is interrupted. Since the safety distance depends on the total stopping time, use the release figure together with the contactor drop-out time and the machine stopping time.

Applications in Oman and the GCC

Packaging, palletising and assembly cells are the main users, together with machine tools fitted with light curtains and port equipment with coded door sensors. Engineers appreciate that one module covers contacts and OSSD signals, which reduces the number of different spares in a maintenance store.

Manual or automatic start in practice

Automatic start means that the outputs close as soon as the input conditions are valid again, so the restart depends entirely on other parts of the machine control. This is acceptable for guards where reopening and reclosing is part of the normal cycle and where the machine itself needs a separate start command. Manual start adds a reset button: after the guard is closed or the e-stop released, somebody must press the button, which gives the operator a clear moment to check that nobody is in the danger zone. The minimum duration of the start impulse is over 250 ms, so a very short tap on the button may not be recognised, and the push button should be of a good quality with a clear stroke.

Cable and supply considerations

The input cable resistance limit of 50 ohm per input and the current of below 30 mA per input set the usable cable length for a given conductor size. For long runs to a remote door sensor use a larger cross-section, keep the cable away from motor leads and variable frequency drive cables, and avoid mixing safety conductors with power conductors in the same multicore cable. The supply of 24 V ac/dc may be taken from a transformer or from a dc power supply, but for the UL rating the catalogue asks for a Class 2 or limited energy source for the 24 V versions. Ripple on a dc supply should stay at or below 10 percent.

Commissioning

  1. Verify the supply of 24 V ac/dc within the tolerance of minus 10 to plus 15 percent.
  2. Connect the input channels and check the cable resistance per input.
  3. Wire the start circuit for manual or automatic start.
  4. Check each device individually and observe the outputs.
  5. Measure the response and release times in the machine and record them.

Related items you may also need: Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 1007 Position Switch, Adjustable Roller | All Pizzato products.

Documents and quotation

The catalogue chapter of the CS AR family is attached to this page with technical data, code structure, pin assignment and input configurations. To request a quotation, send an RFQ with Pizzato CS AR-05V024, the quantity and the delivery destination in Oman or the GCC, and mention the devices connected to the inputs.

Other Models in the CS AR Range

Seven Star LLC supplies models from the CS AR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pizzato CS AR-04V024 Emergency Stop Safety Module, 3NOSafety Switches & Guard LockingView details
Pizzato CS AR-05V024 Safety Module with OSSD InputsSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pizzato CS AR-05V024 Safety Module with OSSD Inputs Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS AR-05V024 Safety Module with OSSD Inputs

Answers from our engineering team on installation, compatibility and integration.

01Which devices can the Pizzato CS AR-05V024 monitor?
Emergency stop contacts, movable guards, magnetic safety sensors and OSSD semiconductor outputs on one or two channels.
02What start mode does the CS AR-05V024 offer?
Code 05 gives manual or automatic start; the monitored start belongs to the CS AR-06 code.
03What are the timing figures of the CS AR-05V024?
Response time is below 300 ms, release time below 15 ms and below 70 ms without supply, with a start impulse over 250 ms.
04What outputs does the CS AR-05V024 have?
Three normally open forcibly guided safety contacts and one normally closed signalling contact.
05What supply does the CS AR-05V024 use?
24 Vac/dc at 50 to 60 Hz with a tolerance of minus 10 to plus 15 percent, below 5 VA on ac or below 2 W on dc.