Grundfos CM 1-5 Self-Priming Multistage Pump

Description

Grundfos CM 1-5 self-priming multistage pump with 5 impellers

The Grundfos CM 1-5 is a horizontal, multistage, end-suction centrifugal pump from the self-priming CM range, built with 5 impellers and chambers in stainless steel (EN 1.4301/AISI 304) and driven by a single-phase mains motor. Within the modular CM system the first figure after the letters is the rated flow at 50 Hz (1 m³/h), so CM 1-5 belongs to the CM 1 group, and the second figure is the number of impellers. This page describes the self-priming build documented in the manufacturer CM self-priming data booklet. Seven Star LLC, an independent supplier in Muscat, quotes CM 1-5 for projects in Oman and the GCC, and is not affiliated with the manufacturer.

The self-priming version is shown in the booklet type key as a pump version letter. Version O has a maximum suction lift of 8 metres and version S a maximum of 4 metres. For the CM 1 sizes the booklet lists only the S version, so CM 1-5 is a 4 m lift pump.

CM 1-5 technical specifications

Parameter Specification
Manufacturer / part number Grundfos / CM 1-5 (self-priming CM)
Pump type Horizontal multistage end-suction centrifugal, self-priming
Rated flow at 50 Hz / impellers 1 m³/h / 5
Pump version (suction lift) S (4 m lift)
Materials in contact with liquid Sleeve, pump shaft, impellers and chambers EN 1.4301/AISI 304; EPDM rubber parts
Shaft seal options in booklet AVBx (0 to +40 °C, 10 bar; +41 to +60 °C, 6 bar) and AQQx (0 to +60 °C, 16 bar)
Maximum ambient / liquid temperature +55 °C / +60 °C
Pipe connection Rp thread (ISO 7/1); 1 in port size in the dimension table
Motor, 50 Hz (1 x 220–240 V) 0.5 kW, frame 71B
60 Hz variant in booklet Not listed for CM 1-5 (60 Hz tables cover CM 1-3, 1-4, 3-3, 3-4, 5-3 and 5-4 only)
Sound pressure level, 50 Hz 52 dB(A)
Net / gross weight, 50 Hz motor 13.1 kg / 15.6 kg (shipping volume 0.02 m³)
Head at zero flow, 0 m suction lift, 50 Hz 0.25 m
Head at 4 m suction lift, zero flow, 50 Hz 41.3 m

Values above are as printed in the manufacturer booklet. Approvals and markings listed there as standard are the C-tick mark, the TR certificate and CE marking, with WRAS and ACS drinking water approvals, and GOST compliance. Further approvals are available only on request to the manufacturer, so confirm anything beyond that for the exact pump code you order.

How CM 1-5 primes and builds pressure

A self-priming CM pump keeps a charge of water in the pump body so the impellers can evacuate air from a dry suction pipe and pull liquid up from below the pump. The booklet quotes a suction lift of up to 8 metres in less than five minutes when the installation and commissioning are done correctly. CM 1-5 carries 5 impellers on one shaft, and each stage adds head, which is why CM 1-5 develops about 0.25 m at zero flow while the first model of the same flow group, CM 1-3, develops 0.25 m. The pump is not a canned-rotor design: a conventional shaft with a mechanical seal separates the liquid from the motor, so a small quantity of grit is tolerated better than in canned-rotor pumps of similar size, according to the booklet.

Because the booklet curves are given per metre of suction lift, you can read the effect directly: for CM 1-5 each additional metre of lift removes about one metre of delivered head at the same flow (for example 0.25 m at 0 m lift against 41.3 m at 4 m lift at zero flow). Plan the duty point after subtracting the lift, not before.

CM 1-5 performance data at 50 Hz

Delivered head in metres against flow in m³/h and suction lift, taken from the 50 Hz table. Columns marked S are valid only for the S version, rows marked O only for the O version. A dash means the combination is outside the published range.

Suction lift (m) 0 0.25 0.5 0.75 1 1.25 1.5
0 0.25 0.5 0.75 1 1.25 1.5 –
1 44.3 43.6 42.3 40.6 38.3 35.5 32.2
2 43.3 42.6 41.3 39.6 37.3 34.5 31.2
3 42.3 41.6 40.3 38.6 36.3 33.5 30.2
4 41.3 40.6 39.3 37.6 35.3 32.5 29.2

For the O version the flow range shown ends at 1.5 m³/h (- m at 0 m lift), while the S version extends to 1.5 m³/h at 0 m lift (- m head). Low-flow duty near the first columns is where this pump works best as a pressure booster; the far right end of the range is a high-flow, low-head condition and should be checked against the motor frame 71B and the inlet conditions.

Where CM 1-5 sits in the CM self-priming range

The 60 Hz curves in the booklet are limited to six models, so CM 1-5 is a 50 Hz selection in this document. Neighbouring models are CM 1-4 and CM 1-6, and their shut-off heads at 0 m lift are 0.25 m and 54.3 m respectively against 0.25 m for CM 1-5. Use them to bracket the duty if the system curve falls between two sizes.

Motor data and electrical notes for CM 1-5

On the 50 Hz single-phase build the booklet assigns a 0.5 kW motor in frame 71B. Current I1/1 spans 3.1 – 2.8 A across the load range, power factor 0.97 – 0.99, efficiency 74 – 70 percent, starting current 16.4 – 14.8 A and speed 2,730 – 2,740 min−¹. The motor is the standard IP55 type, with the cable-gland terminal arrangement shown as a plug-less option in the type key. Remember that single-phase starting current is several times the running current, so check the supply cable and the protection setting against the starting figure for CM 1-5 rather than the running figure alone.

Selection and ordering checklist for CM 1-5

  • Confirm 50 Hz or 60 Hz supply and whether a single-phase 220–240 V line is available at the site.
  • Establish the real suction lift in metres, remembering that each metre of lift costs about 1 m of head, and choose version O or S accordingly.
  • Work out the flow and the discharge head required, then compare with the CM 1-5 table above; check the next size up if the duty falls near the limit of the table.
  • Check liquid temperature against the shaft seal option (AVBx or AQQx) and the pressure limit for that seal.
  • Check ambient temperature against the +55 °C limit and the ventilation around the motor.
  • State the shaft seal materials and any requirement for stainless steel EN 1.4401/AISI 316, which the booklet lists as available on request.

Installation, priming and maintenance of CM 1-5

  • Position and piping. The booklet describes permitted pump positions and recommends a rising suction pipe without air pockets. For CM 1-5 keep the first tapping point above the minimum heights given for the chosen lift (no minimum for a short lift, rising to 0.7 m at 8 m lift on O-version pumps).
  • Priming and commissioning. Fill the pump body through the filling plug, open the discharge path, start the pump and wait for the air to clear; the booklet states priming within five minutes at full lift when installed correctly.
  • Inlet conditions. When the liquid is warm, the flow is high or the suction line is long, the booklet recommends calculating the inlet pressure with the NPSH figure so that CM 1-5 does not cavitate.
  • Maintenance. No special tools are required and service parts are offered as kits, single parts or bulks. Keep a seal kit and a spare set of O-rings in stock where the pump runs continuously.

Typical applications of CM 1-5 in Oman and the GCC

The booklet lists water treatment, domestic pressure boosting, agricultural water supply and rainwater applications for the self-priming CM range. In Oman and the wider GCC that translates into small water treatment skids and filtration feed in the GCC, domestic pressure boosting for villas that draw water from tanks below floor level and farm and greenhouse water supply where wells or storage tanks sit below the pump. At 0.25 m shut-off head and a 1 m³/h class flow, CM 1-5 suits low-flow, higher-head boosting from a tank. Stainless steel wetted parts help where tanks hold slightly saline or treated water, and the +55 °C ambient limit should be checked for pumps installed in unshaded outdoor enclosures during summer.

CM self-priming family compared with CM 1-5

The table lists the thirteen self-priming CM models in the booklet. Pick a neighbour only after checking the full table against your duty point.

Model Motor 50 Hz (kW) Head at 0 flow, 0 m lift (m) Net weight (kg)
CM 1-3 0.3 0.25 11.7
CM 1-4 0.5 0.25 12.7
CM 1-5 0.5 0.25 13.1
CM 1-6 0.5 54.3 13.7
CM 3-3 0.5 27.9 12.4
CM 3-4 0.5 37.2 12.7
CM 3-5 0.5 46.5 13.1
CM 3-6 0.67 55.8 15.1
CM 5-3 0.5 27.9 12.4
CM 5-4 0.67 37.3 14.1
CM 5-5 0.9 46.6 15.5
CM 5-6 1.3 55.9 21.8
CM 5-7 1.3 65.3 21.9

CM 1-5 sits in the middle of the head range of its group; its siblings in the same flow group are CM 1-3, CM 1-4, CM 1-6.

Information to send with an RFQ for CM 1-5

  • Exact model CM 1-5 and quantity.
  • Supply frequency and voltage (50 Hz 220–240 V or 60 Hz 220 V single phase).
  • Pump version O or S, or the actual suction lift in metres.
  • Duty flow and required discharge head.
  • Liquid, temperature and any solids content.
  • Shaft seal option and any special material request.
  • Delivery location in Oman or the GCC and required date.

Documents and quotation

The manufacturer CM self-priming data booklet is attached on this page. It contains the curves, motor tables, weights and type key that this description follows, and should be read together with your project specification before ordering CM 1-5.

Send the model, supply and duty details and Seven Star LLC will quote CM 1-5 with lead time and available certificates for delivery to Oman and the GCC.

Other Models in the Grundfos Cm Selfpriming Range

Seven Star LLC supplies models from the Grundfos Cm Selfpriming range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Grundfos CM 1-3 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 1-4 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 1-5 Self-Priming Multistage PumpCentrifugal PumpsYou are viewing this model
Grundfos CM 1-6 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 3-3 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 3-4 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 3-5 Self-Priming Multistage PumpCentrifugal PumpsView details
Grundfos CM 3-6 Self-Priming Multistage PumpCentrifugal PumpsView details
Datasheets & Documents
  • PDF Datasheet Grundfos CM 1-5 Self-Priming Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Grundfos is a Danish pump manufacturer, founded in 1945 by Poul Due Jensen in Bjerringbro, Denmark, where the group is still headquartered. It started by building water pumps for local farms and grew into one of the world's largest pump makers. The company is majority-owned by the Poul Due Jensen Foundation, which keeps it independent and family-linked.

Seven Star LLC lists Grundfos multistage, end-suction, borehole, circulator and dosing pumps and booster sets, and supplies them to contractors and plant operators in Oman by product number and duty point.

Grundfos company profile

Founded 1945, Bjerringbro, Denmark, by Poul Due Jensen
Headquarters Bjerringbro, Denmark
Ownership Majority-owned by the Poul Due Jensen Foundation
First products Water supply pumps for farms
Product families CR vertical multistage pumps, SP submersible borehole pumps, NB and NK end-suction pumps, MAGNA and ALPHA circulators, Hydro MPC booster sets, SE and SL wastewater pumps, DDA dosing pumps

Milestones

  • 1945: Poul Due Jensen founds the company in Bjerringbro.
  • 1967: The company takes the name Grundfos.
  • 1975: The Poul Due Jensen Foundation is established.

Grundfos pump families on this page

  • CR: vertical multistage centrifugal pump for boosting, boiler feed and process water
  • NB: single-stage end-suction close-coupled pump for transfer and circulation
  • SP: submersible borehole pump for wells
  • MAGNA3: electronically controlled circulator for heating and chilled water loops
  • Hydro MPC: packaged booster set with several pumps and a controller
  • DME: digital dosing pump for chemical injection

Where Grundfos pumps are used

Pressure boosting in towers and housing compounds, chilled water circulation, irrigation and groundwater abstraction, reverse osmosis feed, wash-down and boiler feed in factories, and chlorine or antiscalant dosing in water treatment. In the GCC the heaviest demand comes from building services, water supply and desalination pretreatment.

Grundfos products we list

Family Examples
Pumps CR Vertical Multistage Centrifugal Pump, DME Digital Dosing Pump, Hydro MPC Booster Set, MAGNA3 Circulator Pump, NB Single-Stage End-Suction Centrifugal…, NK Long-Coupled Single-Stage End-Suction…, SP Submersible Borehole Pump, TPE3 In-Line Circulator Pump

Ordering Grundfos pumps and parts: what we need

The nameplate shows a type designation, a product number and a production code. The product number is the surest reference for an identical pump or for the correct spare kit, so send it with the model line. For a new selection give the flow and head, the liquid with its temperature and any solids or chemicals, suction conditions, motor voltage, phase and frequency, and the pipe connections. For an SP pump add the borehole diameter, static and dynamic water level and the cable length. For a DME state the dosing rate, back pressure and chemical.

Facts checked against Grundfos' own history pages, October 2026.

FAQ

Questions about the Grundfos CM 1-5 Self-Priming Multistage Pump

Answers from our engineering team on installation, compatibility and integration.

01What does the CM 1-5 designation mean?
The first number after CM is the rated flow at 50 Hz, here 1 m³/h, and the second number is the count of impellers, here 5. The model is part of the modular Centrifugal Modular family.
02How high can the CM 1-5 lift water from below the pump?
The booklet lists the S version, which has a maximum suction lift of 4 metres. Each metre of suction lift reduces the available head by about one metre, so at 4 m lift the shut-off head falls from 0.25 m to 41.3 m on 50 Hz.
03What liquid temperature and pressure limits apply to CM 1-5?
The booklet allows 0 to +60 °C with the AQQx seal up to 16 bar, and with the AVBx seal 0 to +40 °C up to 10 bar and +41 to +60 °C up to 6 bar. Maximum ambient temperature is +55 °C.
04Which motor does the CM 1-5 use on a 50 Hz supply?
The 50 Hz single-phase 220–240 V build uses a 0.5 kW motor in frame 71B with IP55 protection, giving a running current of 3.1 – 2.8 A across the load range.
05Is there a datasheet for CM 1-5?
The manufacturer self-priming CM data booklet is attached to this page. It covers the CM 1-5 curves, motor data, weights and type key. Seven Star LLC is an independent supplier and not affiliated with the manufacturer.