Brand:

Cortem EJBE-6 Large Ex de Control Board

Description

Cortem EJBE-6: what the code means

Looking for Cortem EJBE-6? This is a largest Ex de control board enclosure of the EJBE series for switchgear, drives and heavy control panels from the EJBE Ex de control board series (Ex d aluminium enclosure with Ex e stainless terminal enclosure). This is the heavyweight of the range: 1537 x 650 x 470 mm outside, an Ex d compartment of 760 x 540 x 353 mm, an Ex e compartment of 584 x 390 x 405 mm and a mass of 182 kg. The marking printed in the data sheet is II 2GD Ex de IIB+H2 Gb / Ex tb IIIC Db, IP66, with ATEX CESI 15 ATEX 066U and IECEx CES 15.0018U for the empty enclosure listed as the certification basis.

Seven Star LLC works as an independent supplier for Oman and the GCC and is not affiliated with the manufacturer. The values quoted here are summarised from the published data sheet, so check the current edition at order time.

What stands out on this unit

  • Extra large Ex d compartment 760 x 540 x 353 mm for drives and breakers
  • Separate Ex e terminal compartment of 584 x 390 x 405 mm
  • Terminal capacity up to 4×99 WDU 2.5 mounted vertically
  • Sealed bushings in nickel plated brass or stainless steel between compartments
  • Cast stainless hinges and lid options such as windows and indicator lights

Cortem EJBE-6 ratings and dimensions

Part number EJBE-6
Series (584, 390, 405)
Outside dimensions A x B x C x D 1537 x 650 x 470 x 450 mm
Ex d inside a x b x c1 760 x 540 x 353 mm
Ex e inside a1 x d x c2 584 x 390 x 405 mm
Mounting X x Y, F 680 x 580 mm, F = 14
Weight 182 kg
Marking, empty enclosure II 2GD Ex de IIB+H2 Gb, Ex tb IIIC Db, IP66
Certificates, empty enclosure CESI 15 ATEX 066U; IECEx CES 15.0018U
Control version marking II 2GD Ex de IIB+H2 T6/T5 Gb, Ex tb IIIC T85/T100°C Db (CESI 12 ATEX 026)
Ambient range -50°C to +80°C empty (-40°C with polycarbonate lights)
Ex d rated voltage and current max. 690 Vac; 50 A; 50 to 60 Hz
Dissipation T6 / T5 with lights / T5 without, +40°C 600 W / 600 W / 910 W
Dissipation at +55°C 460 W / 460 W / 680 W
Ex e terminals WDU 2.5, vertical / horizontal 4×99 / 5×62
Ex d body and lid Low copper aluminium alloy, polyester RAL 7035
Mounting feet Electrogalvanised steel brackets
Gasket Silicone, resistant to acids, hydrocarbons and temperature extremes

How EJBE-6 differs from other EJBE variants

Compared with the other EJBE variants, the differences that matter for EJBE-6 are these.

  • Outside length 1537 mm, against 661 mm for EJBE-3 and 771 mm for EJBE-4B.
  • Mass 182 kg, versus 25 kg for the size 3 unit.
  • Dissipation 600 W (T6, +40°C) compared with 75 W for EJBE-3.
  • Terminal capacity 4×99 WDU 2.5 vertical or 5×62 horizontal, against 2×27 for size 3.

Application areas in Oman and the GCC

Plant engineers in Oman reach for EJBE-6 when a project has to terminate or distribute circuits inside a classified area: process skids, pump and compressor stations, water pumping sites and manufacturing lines with solvent or dust hazards. Such a size is used when a whole motor control centre section, frequency drive or large distribution board must sit in a Zone 1 or Zone 21 location with a separate terminal compartment. The manufacturer groups its use cases under refineries, chemical and petrochemical plants, onshore and offshore plants.

Selection and compatibility notes

Start the selection of EJBE-6 from the area classification. Confirm that the gas group and the dust group of your zone are covered by the marking II 2GD Ex de IIB+H2 Gb / Ex tb IIIC Db, IP66, then check the ambient range of -50°C to +80°C without polycarbonate indicator lights on the lid (-40°C with them) for the empty enclosure against the site extremes. The sheet allows 600 W at +40°C for T6 and 910 W for T5 without lights, falling to 460 W and 680 W at +55°C, the highest values among the EJBE sizes. Cable gland or plug entries must be certified for the same zone and be fitted with their gaskets so that the ingress rating is kept.

Installing and servicing EJBE-6

Mounting EJBE-6 is simple if the fixings are laid out first: use the listed centres, take the earth bond from the dedicated screw, and torque the cover bolts in a cross pattern. At 182 kg, use lifting gear with the 680 x 580 mm fixing centres and 14 mm holes, and plan a floor or frame support that can take the weight. Finish with insulation testing, a check that every unused entry is closed with a certified plug, and a signed inspection record.

To maintain Cortem EJBE-6, schedule a visual check of the finish, the lid gasket and the fasteners, retighten what has loosened, and clear dust from cable entries. Because the assembly is large, inspect the flange gasket and every sealed bushing for corrosion and the tightness of the many cover bolts at each shutdown. If a lid or body is damaged around the joint, replace the enclosure instead of repairing the machined surfaces.

Accessories, ordering and FAQ recap

If EJBE-6 is part of a larger bill of material, list the glands, plugs, terminals and any special thread or colour options in the same request. Spare and replacement needs for older plants are welcome, and we will confirm availability against the part number you give.

Treat the code EJBE-6 as the whole order specification: it fixes the size, the entry layout and the family. When you replace a unit, check the old nameplate, the fixing pattern and the certificate number, then confirm them against the data above; the marking to match is II 2GD Ex de IIB+H2 Gb / Ex tb IIIC Db, IP66.

In short, EJBE-6 is the largest control board unit in the EJBE series; the questions cover weight, dissipation, terminals, voltage and the RFQ.

Documents and quotation

The manufacturer data sheet for the EJBE range is attached to this page as a PDF so you can check dimensions, marking and certificate numbers. To receive a quotation, send the RFQ with part number EJBE-6, the quantity, the delivery place and any option such as a special thread or paint colour.

Other Models in the EJBE Range

Seven Star LLC supplies models from the EJBE range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Cortem EJBE-3 Ex de Control Board EnclosureSwitchgear, Enclosures & DistributionView details
Cortem EJBE-6 Large Ex de Control BoardSwitchgear, Enclosures & DistributionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Cortem EJBE-6 Large Ex de Control Board Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Cortem is the Italian maker of explosion-proof and increased-safety electrical equipment: Ex d and Ex e lighting, enclosures, control stations, plugs and sockets, cable glands and signalling devices. Marco Rossi and Renato Gratton founded the company on 24 February 1968 in Villesse, in the Friuli Venezia Giulia region of north-east Italy. Cortem S.p.A. heads the Cortem Group, which also includes Elfit and the Fondisonzo foundry, and supplies onshore and offshore oil and gas, chemical and industrial plants.

Seven Star LLC is an independent supplier in Muscat. We list Cortem junction boxes, lighting, plugs and sockets and control stations for oil and gas and process projects in Oman and the GCC.

Cortem company profile

Founded 24 February 1968, Villesse (Gorizia), Italy
Founders Marco Rossi and Renato Gratton
Name From the Italian for electromechanical construction and technical representation
Group companies Cortem S.p.A., Elfit and Fondisonzo
Approvals ATEX and IECEx certified explosion-protected equipment
Product families Ex d and Ex e luminaires and LED fittings, emergency and exit lights, obstruction lights, junction and control boxes, control stations, plugs and sockets, cable glands, alarm and signalling devices

Milestones

  • 1968: Marco Rossi and Renato Gratton found Cortem in Villesse on 24 February.
  • 2011: Research and development on LED lighting for hazardous areas begins.
  • 2012: The first Cortem LED fixture series is launched.
  • 2022: The third generation of Cortem LED fixtures is released.

Cortem product series

Enclosures include the EJBX stainless steel Ex d junction boxes, EJBC aluminium Ex d boxes for gas group IIC, the SA and SAG Ex eb aluminium boxes in 18 sizes and the EJBE and EJBXE Ex de control and distribution boards. Control and power connection products include the CMD Ex e fibreglass control stations and the PYN, SPYN and CMBSP07 Ex plugs and sockets from 16 to 125 A.

Lighting covers the SLED-ME and EVL-40 Ex LED floodlights, the Ex nR SLED-MN and EVNL-40 floodlights for zone 2, the LIFEX-M linear fixture, the FLOWEX high bay, the EVML low bay, STREETEX street lighting and the XLFE-LIB and XLFE-MIA obstruction lights for stacks and towers. The GRDE-4200 is an electronic earthing system for road tanker loading bays.

Where Cortem equipment is used

Refineries, gas plants, tank farms and loading terminals, offshore platforms and ships, chemical and pharmaceutical plants and mining. Products are certified to ATEX and IECEx, with other schemes according to model.

Cortem products we list

Family Examples
Automation Accessories CMBSP07 Ex GRP Plugs and Sockets 16 A to 125 A, CMD Ex e Fibreglass Control and Signalling, EJBC Aluminium Ex d Junction Boxes for Gas, EJBE-EJBXE Ex de Control and Distribution, EJBX Stainless Steel Ex d Junction Box IIB+H2, EV Ex d Luminaires for Traditional and LED, EVL-40 Ex LED Floodlight with 40 Degree Beam, EVML Ex LED Low Bay Luminaire and 14 more

Ordering Cortem products: what we need

Send the model code, the zone and gas or dust group, temperature class, ingress protection, the certification scheme required, and for enclosures the size, entries and internal components. For lighting give the wattage, voltage and mounting; for plugs and sockets the current, poles and voltage.

Facts checked against Cortem Group's published company history, October 2026.

FAQ

Questions about the Cortem EJBE-6 Large Ex de Control Board

Answers from our engineering team on installation, compatibility and integration.

01How heavy is Cortem EJBE-6?
The selection chart lists 182 kg, so plan lifting equipment and a robust support.
02What dissipation is allowed in Cortem EJBE-6?
At +40°C the Ex d box may dissipate 600 W for T6 and 910 W for T5 without lights; at +55°C the limits are 460 W and 680 W.
03How many terminals does Cortem EJBE-6 hold?
With WDU 2.5 terminals the sheet gives 4x99 for vertical mounting and 5x62 for horizontal mounting.
04What is the maximum rated voltage of Cortem EJBE-6?
The Ex d enclosures are rated up to 690 Vac and 50 A at 50 to 60 Hz according to the data sheet.
05How do I request Cortem EJBE-6?
Send an RFQ with EJBE-6, quantity, equipment to be installed and delivery location in Oman or the GCC.