Brand:

Bürkert 419593 Type 8020 Low Power Paddle Wheel Flow Sensor Long

Description

Overview

Bürkert 419593 is a low-consumption relative of the common paddle wheel sensor: the Bürkert Type 8020 in the Hall Low Power version with the long sensor stem. It is not powered from a separate supply. Instead it draws less than 0.8 mA from the Bürkert transmitter it is connected to, which keeps the energy budget of the whole measuring loop very small. The paddle wheel and armature are PVDF, the axis and bearing are ceramic, and the seal is FKM, so the wetted materials match the other Type 8020 sensors. Seven Star LLC is an independent supplier serving Oman and the GCC.

Who should choose the Low Power code

This sensor is only meant for the Low Power flow transmitters of the same maker, namely the Type 8025 transmitter and the Type 8022 pulse divider family. Anyone planning to connect it to a PLC with a standard 24 V input should look at the ordinary Hall version instead. Choosing 419593 is correct when the display transmitter is already installed and the sensor itself needs replacing, or when a new low-power loop is being built around an 8025.

Bürkert 419593 parameters

Item Value
Article number 419593
Version Type 8020 Hall Low Power, long sensor
Power from the connected Bürkert transmitter; consumption up to 0.8 mA
Output one NPN open-collector transistor, pulse frequency, up to 10 mA, 0 to 300 Hz
Duty cycle one half plus or minus 10 percent
Pipe range DN 20 to DN 400 with Insertion fitting Type S020
Flow rate 0.5 to 75000 l/min
Flow velocity 0.3 to 10 m/s
Linearity plus or minus 0.5 percent of full scale
Repeatability plus or minus 0.4 percent of the measured value
Wetted parts PVDF, ceramic Al2O3 axis and bearing, FKM seal (EPDM optional)
Max. pressure PN 10
Fluid temperature depends on fitting material: PVC 0 to 50 degrees C; PP 0 to 80; PVDF, stainless steel, brass minus 15 to plus 80
Ambient temperature minus 15 to plus 60 degrees C
Process connection G2 for fitting Type S020

How 419593 differs from other Type 8020 variants

There are four Type 8020 codes in the ordering chart. 419587 and 419589 are the Hall variants powered by 12 to 36 V DC, with two transistor outputs of up to 100 mA, one NPN and one PNP. 419591 and 419593 are the Low Power pair, differing from one another in sensor length only: 419591 is the short stem and 419593 is the long stem. The longer stem is the one required for saddles, screw-on spigots and some welding or fusion sockets, so it is the right choice for the larger pipes in the DN 200 to DN 400 range where the fitting is thick.

Typical places to use it

Field sites without a convenient power point, remote water transfer lines, irrigation and farm supply, temporary monitoring on rented skids, and standalone batching stations all suit a low-power flow loop. In the Gulf, remote pumping stations and desert camps often have limited electrical infrastructure, so a compact transmitter with a Low Power sensor keeps cabling and supply demands to a minimum. The unit also fits in tight budgets, since there is no separate power supply.

Selection guidance

Confirm three points before ordering. The transmitter must be a Low Power model. The fitting must accept the long stem. And the liquid must be free of long fibres and heavy solids, with no more than 1 percent solids by volume and particle size under 0.5 mm. The viscosity limit is 300 cSt, and the supply voltage figure of the Hall variant does not apply here. If your fitting is plastic, check the fluid temperature against its limit as listed above.

Understanding the pulse output

A paddle wheel sensor does not measure volume directly. It counts rotations by means of the Hall element and sends the pulses to the transmitter, which converts frequency into flow with the help of a K factor, expressed as pulses per litre. That factor is fixed by the geometry of the fitting and the pipe diameter, which is why the transmitter must know the fitting in use. With a single NPN output, wiring is simple because only one signal output is used. The output switches at up to 300 Hz, comfortably above the pulse rates that real pipes generate at the maximum velocity of ten metres per second.

Linearity and repeatability in use

The data sheet states plus or minus 0.5 percent of full scale for linearity and plus or minus 0.4 percent of the measured value for repeatability, both under reference conditions. For control and for totalising these figures are adequate in most utility services, but applications such as custody transfer require a different measuring principle. A clean pipe, steady flow and correct fitting orientation are the three conditions that protect these values over the sensor life.

Installation

Push the sensor into its fitting, tighten the union nut, and orient the arrow. Use the supplied or recommended shielded cable with a maximum length of 50 m and keep it away from motor cables. Keep the paddle wheel in a full pipe. After the connection is made, the transmitter should be configured with the K factor of the installed fitting, and a teach-in can be run to tighten the accuracy.

Maintenance

Inspect the paddle wheel at each shutdown, clean any film or scale, and make sure it spins freely by blowing gently on it. If readings drift, check the fitting seal and the cable gland before suspecting the sensor electronics.

Ordering Bürkert 419593

Tell us the transmitter model, the fitting, the nominal pipe size and the quantity. We can quote the matching fitting and the cable plug as well.

When requesting a quotation for Bürkert 419593, quote the full Bürkert 419593 designation from the nameplate or order code so the correct variant is matched, and mention the plant tag if the unit replaces an installed device.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert 020293 Type 0330 Brass 2/2-Way Solenoid Valve | All Bürkert products.

Documents and quotation

The manufacturer data sheet for Type 8020 is attached, including the ordering chart that separates the Hall and Low Power variants. Send an RFQ with the part number Bürkert 419593, the quantity and your delivery location in Oman or the GCC, and we will answer with availability and lead time.

Other Models in the 8020 Range

Seven Star LLC supplies models from the 8020 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 419587 Type 8020 Insertion Paddle Wheel Flow SensorTurbine & Positive Displacement FlowmetersView details
Bürkert 419593 Type 8020 Low Power Paddle Wheel Flow Sensor LongTurbine & Positive Displacement FlowmetersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 419593 Type 8020 Low Power Paddle Wheel Flow Sensor Long Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 419593 Type 8020 Low Power Paddle Wheel

Answers from our engineering team on installation, compatibility and integration.

01What is Bürkert 419593?
Bürkert 419593 is a Type 8020 Hall Low Power insertion paddle wheel flow sensor with a long stem, powered through a compatible Bürkert transmitter.
02Can 419593 run from a 24 V supply?
No. 419593 draws less than 0.8 mA from the associated Low Power transmitter such as Type 8025 and is not for a direct 12 to 36 V connection.
03What output does Bürkert 419593 have?
A single NPN open-collector transistor pulse output up to 10 mA with a frequency of 0 to 300 Hz.
04How is 419593 different from 419591?
Both are Low Power versions; 419591 has the short sensor stem and 419593 has the long stem for saddles, screw-on spigots and some sockets.
05What pipe sizes does Bürkert 419593 cover?
With the Insertion fitting Type S020 it covers pipes from DN 20 to DN 400, flows of 0.5 to 75000 l/min and velocities from 0.3 to 10 m/s.