Brand: Pizzato
Pizzato CS MP201M0 Programmable Safety Module, Gemnis
Description
Overview
When a machine has a handful of safety functions, wiring one relay per function quickly fills a cabinet. The Pizzato CS MP201M0 replaces that pile of relays with one programmable safety module from the Gemnis series. It has 8 safety inputs, 8 test signal outputs, 4 signalling outputs and a relay stage of three normally open safety contacts, and it is programmed through its USB port with the graphical Gemnis Studio software. Its limits are Maximum SIL 3, PL e and category 4. The housing is 45 mm wide and the M0 in the code means connector terminals with screw clamps. Seven Star LLC is an independent supplier serving Oman and the GCC.
Inside the module
Pizzato builds the Gemnis modules with a redundant, self-monitoring structure. Two processors run the application program at the same time and compare their results, and the module performs a self-test during start-up that takes less than 2 seconds. The inputs accept the whole list of safety devices that the catalogue names: mechanical safety switches, switches with guard locking solenoid, magnetic sensors, light barriers, emergency stop buttons and rope switches, safety mats, two-hand controls, selector switches and enabling devices. The program is built from function blocks such as AND, OR, delays, counters and external device monitoring, and can be tested in simulation before it is loaded.
Specification of Pizzato CS MP201M0
| Characteristic | Catalogue value |
|---|---|
| Safety inputs I | 8 |
| Test outputs T | 8 |
| Safety outputs | 3NO relay contacts |
| Signalling outputs O | 4 semiconductor outputs |
| Programming | Gemnis Studio via USB port |
| Safety limits | Maximum SIL 3, PL e, category 4 |
| MTTFD | 135 years |
| PFHD | 1.44E-09 per hour |
| Mission time | 20 years |
| System response time | Below 40 ms |
| Dimensions (H x L x W) | 111.5 x 45 x 99 mm |
| Supply | 24 Vdc, plus or minus 15 percent, below 3 W without load |
| Input circuits | 24 V, 5 mA; off 0 to 8 V, on 12 to 24 V; minimum signal 10 ms |
| Relay rating (UL) | 230/240 Vac, 4 A general use, C300 pilot duty |
| Operating temperature | 0 to plus 55 degrees Celsius; storage minus 20 to plus 70 |
| Protection | IP40 housing, IP20 terminal strip, PA 66 V0 |
| Approvals | EC type examination M6A 075157 0032, TUV SUD Z10 075157 0031, UL E131787 |
How the Pizzato CS MP201M0 differs from the other Gemnis 45 mm modules
Seven more modules, the CS MP202M0 to CS MP208M0, share the same 45 mm width, and the numbers in the table of the catalogue separate them. The CS MP202M0 offers 16 inputs but only 4 test outputs and 4 PNP safety outputs. The CS MP204M0 has 12 inputs, 4 test outputs and the same 3NO relay output as this code. The CS MP206M0 trades inputs for 12 signalling outputs. In contrast, the Pizzato CS MP201M0 has the largest number of test signals in this group, 8 against 4, which gives more test lines for sensors that are monitored by test pulses, and it keeps a relay stage, which suits loads at higher voltage or current than PNP outputs can drive. Its MTTFD of 135 years and PFHD of 1.44E-09 per hour are the figures to use in the calculation of the safety function.
Typical uses
One module can supervise, for instance, two emergency stops, a guard switch on each of three doors and a two-hand control, and then give separate commands to a main contactor, a valve and a PLC. It is attractive to machine builders in Oman who ship automation cells to customers in the Gulf and need a compact, documented solution. Another use is retrofit: an old machine with a bank of relays and a tangle of jumpers can be replaced with one programmable unit and a clear connection report generated by the software.
Choosing the wiring concept
The test outputs T are the key to detecting short circuits between channels. A device with two tested channels is wired so that each channel is fed from its own test line, and the program expects the test pattern to come back on the matching input. A safety mat, a rope switch or a light barrier with OSSD outputs may need a different connection, and the catalogue lists the sensor types that can be defined in the software, from a single channel that cannot be tested to a pair of tested channels that may be crossed or not. Before ordering, draw the list of devices, assign each to a sensor type, count the inputs and test lines, and check that the totals fit the 8 inputs and 8 test outputs of this code. If the count exceeds that, the larger modules of the series are the next step.
Programming and validation
Gemnis Studio is available after registration on the manufacturer website and runs on Windows 10 or later with the .NET 4.6.2 runtime, a processor of at least 1 GHz and a screen of 1280 by 800. The program can be protected with a password. After loading the program the designer must validate it with a real test of every input and output. The software can print a connection report and a program report for the technical file.
Installation notes
Use 60 or 75 degrees Celsius copper conductors of 30 to 12 AWG and tighten terminals to 5 to 7 lb in. The total current of the signalling and test outputs is limited to 0.5 A, and the internal short circuit protection of the outputs is electronic. Keep the cable capacitance of input lines below 470 nF to ground and between conductors, as the catalogue states, and keep the module in an enclosure because the protection is IP40.
Maintenance
After any change to the program, repeat the validation. Save the project file and its password in a controlled archive, because a module cannot be reprogrammed without them. Keep a spare module with the same code when the machine is critical, then load the saved program and test it.
Related items you may also need: Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 1007 Position Switch, Adjustable Roller | All Pizzato products.
Points to confirm for the Pizzato CS MP201M0
- If the Pizzato CS MP201M0 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Pizzato CS MP201M0 request we confirm the exact code, new or surplus condition and lead time in writing.
- Dimensions, ratings and connection data for the Pizzato CS MP201M0 are in the datasheet attached to this page.
- The Pizzato CS MP201M0 belongs to our safety switches & guard locking range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Pizzato CS MP201M0 on critical service often hold a spare unit in the store.
Documents and quotation
The Pizzato catalogue chapter for the CS MP programmable modules is attached to this page and includes the module table, technical data and terminal diagrams. To request a quotation, send an RFQ with Pizzato CS MP201M0, the quantity and the delivery location in Oman or the GCC, and mention if you need a programming cable or a second module so that we can quote everything together.
Datasheets & Documents
- Datasheet Pizzato CS MP201M0 Programmable Safety Module, Gemnis Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS MP201M0 Programmable Safety Module,
Answers from our engineering team on installation, compatibility and integration.
01What inputs and outputs does the Pizzato CS MP201M0 have?
It has 8 safety inputs, 8 test outputs, 4 signalling outputs and three normally open relay safety contacts.
02How is the CS MP201M0 programmed?
With the Gemnis Studio graphical software over the integrated USB port; the software runs on Windows 10 or later.
03What safety figures does the CS MP201M0 give?
MTTFD is 135 years, PFHD is 1.44E-09 per hour, mission time 20 years and the limits are Maximum SIL 3, PL e and category 4.
04What supply does the CS MP201M0 need?
24 Vdc with plus or minus 15 percent tolerance, drawing below 3 W without load and protected by a PTC element.
05What is the response time of the CS MP201M0?
The system response time is below 40 ms, and the module measures 111.5 x 45 x 99 mm.


















Reviews