Small, light and tolerant of extreme temperatures, the ebm-papst 8556 N is an AC axial panel compact fan with an 80 by 80 millimetre frame. Its datasheet allows operation from minus 40 up to plus 90 degrees Celsius, a span that few fans of this size can match. It is meant for equipment that must run in unheated outdoor kiosks, in hot enclosures near process heat, or in machinery that is cold-started in winter. Seven Star LLC is an independent supplier serving Oman and the GCC. The notes below summarise the datasheet entries for the ebm-papst 8556 N and explain what to check before you buy a replacement.

Performance and size

The fan is supplied from a single phase 230 volt, 50 hertz network and runs at 2800 revolutions per minute, consuming 12 watts. It delivers 50 cubic metres of air per hour at free air, with 4.5 bel sound power and 31 dB(A) sound pressure. The case is die-cast aluminium, 80 by 80 by 38 millimetres, the impeller is sheet steel painted black, and the complete fan weighs 0.490 kilograms. Air is exhausted over the struts. The L10 life at 40 degrees is 52500 hours, falling to 15000 hours at the maximum temperature, a figure that reflects the severe heat of the upper limit.

Data for ebm-papst 8556 N

Item Value
Type ebm-papst 8556 N, AC axial panel compact fan
Phase 1~
Nominal voltage 230 VAC
Frequency 50 Hz
Speed 2800 rpm
Power consumption 12.0 W
Air flow 50 m3/h
Sound power level 4.5 B
Sound pressure level 31 dB(A)
Minimum ambient temperature minus 40 degrees C
Maximum ambient temperature 90 degrees C
Weight 0.490 kg
Dimensions 80 x 80 x 38 mm
Impeller sheet steel, painted black
Housing die-cast aluminium
Airflow direction exhaust over struts
L10 at 40 degrees C 52500 h
L10 at maximum temperature 15000 h

Why the temperature range matters

Most standard fans of this size are specified from minus 10 or minus 20 degrees. The ebm-papst 8556 N goes to minus 40, so a grease that stays fluid and a motor that starts reliably at very low temperature are part of the design. At the other extreme, the plus 90 degree limit allows the fan to sit in a hot air stream, for instance in a heater cabinet or in a box beside a hot process pipe. For installations in Oman the hot end is usually the real challenge, because enclosures standing in the sun can reach very high internal temperatures. A fan with a high temperature limit is then a safer foundation than one that only just meets the requirement.

How 8556 N differs from larger panel fans

Other panel fans in the same series are larger. The 3500 has a 92 millimetre frame and moves 73 cubic metres per hour at 115 volts and 8 watts; the 9900 has a 119 millimetre frame, moves 135 cubic metres per hour at 115 volts and 12 watts, and has a plastic impeller. The ebm-papst 8556 N is the smallest of these three, the only one for 230 volts and 50 hertz, and the one with the widest temperature range. Choose it where space is tight and the supply is 230 volts, and choose a larger fan if you need more flow than 50 cubic metres per hour.

Applications in industry

Typical locations include small control boxes, compact power supplies, heater enclosures, measuring instruments, telecom outstations, and machine electronics. In the Gulf, equipment that sits on the roof of a pumping station or beside a pipeline often needs forced ventilation to keep electronics under their own limits. Because the fan has no electronics, it is not sensitive to dirty mains in the way that EC fans can be, and a simple thermostat in the supply line can switch it as required.

Selection checklist

  • 230 VAC, 50 Hz, single phase on the supply.
  • Square frame of 80 millimetres and 38 millimetres depth.
  • Flow of 50 cubic metres per hour is enough for the heat load.
  • Exhaust over struts; allow clear space on both sides of the fan.
  • Ambient temperatures from minus 40 to plus 90 degrees Celsius.

Installation and checks

Switch off the supply, remove the old fan, and clean the aperture. Mount the new fan with the arrow showing the exhaust direction and tighten the four fixings evenly so the aluminium frame is not distorted. Connect the supply by the method your panel requires, including protective earth if the housing is bonded. Switch on, confirm that the fan reaches speed quickly, listen for rubbing, and check the cabinet temperature over the next hour. Keep leads clear of the blades and fix them with ties so that vibration cannot chafe the insulation.

Maintenance

Dust accumulates on blades and reduces airflow without anyone noticing, so clean them on every inspection with a brush and vacuum. Because the calculated life at the maximum temperature is shorter than at 40 degrees, fans working in hot enclosures should be replaced earlier than the nominal figure suggests, ideally at scheduled shutdowns. Never use water jets directly on the motor.

Ordering ebm-papst 8556 N

When asking for a quotation, give the type, the quantity and the delivery point in Oman or the GCC. If the fan to be replaced has no label, a photograph of the frame and a note of the supply voltage will be enough to cross-check it against the datasheet before the order is confirmed. We can also supply guards and filters on request, so please mention them in the RFQ.

Choosing between a fan and other cooling options

Forced air is not always the right answer. A sealed enclosure with an outdoor rating cannot take outside air without a filter, so some designers use heat exchangers or small cooling units. Where the heat load is small and the cabinet is allowed to breathe through a filter, a compact axial fan such as this one is the simplest and cheapest option. It needs no refrigerant, no control electronics and almost no maintenance. The key is to calculate the worst-case temperature rise, not the average one. In a Gulf summer the air outside a kiosk can exceed 45 degrees in the shade and much more in direct sun, so a fan that can tolerate an air temperature of 90 degrees gives a margin that fans limited to 60 or 70 degrees do not.

Document the installation with the type, date and location so that the next technician knows when it was fitted. Fix a label inside the cabinet door stating the fan type and the supply voltage. Misidentified fans, for example a 115 volt fan swapped into a 230 volt circuit, are a recurring cause of burnt windings, and a clear label prevents this simple mistake.

Related items you may also need: ebm-papst Industrial Cooling Fan | ebm-papst R1G175-AB41-02 DC Fan | ebm-papst R1G225-AF11-52 DC Fan | All ebm-papst products.

Points to confirm for the ebm-papst 8556 N

  • If the ebm-papst 8556 N is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each ebm-papst 8556 N request we confirm the exact code and lead time in writing.
  • Dimensions, ratings and connection data for the ebm-papst 8556 N are in the datasheet attached to this page.
  • The ebm-papst 8556 N belongs to our industrial fans & blowers range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.

Documents and quotation

The manufacturer’s datasheet is attached, with nominal data, technical description, drawing and air performance curve. Send your RFQ with ebm-papst 8556 N, the quantity and the delivery location, and tell us if your design needs a particular lead length.

Datasheets & Documents
  • PDF Datasheet ebm-papst 8556 N AC Axial Panel Fan 80 mm 230 V Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ebm-papst is a German family-owned maker of fans and motors, headquartered in Mulfingen. It was founded in 1963 by Gerhard Sturm and Heinz Ziehl as Elektrobau Mulfingen (ebm) and took its current name after acquiring Papst in 1992. ebm-papst makes EC fans, blowers and motors for ventilation, cooling and air conditioning.

Seven Star LLC is an independent supplier in Muscat. We list ebm-papst fans for equipment cooling in Oman and the GCC.

ebm-papst company profile

Founded 1963, Mulfingen, Germany
Founders Gerhard Sturm and Heinz Ziehl
Headquarters Mulfingen, Germany
Ownership Family-owned
Product families RadiCal and R1G EC centrifugal fans, axial fans, compact DC fans, EC motors

Milestones

  • 1963: Elektrobau Mulfingen is founded.
  • 1992: ebm acquires Papst and becomes ebm-papst.

ebm-papst product series

Centrifugal fans include the R1G175-AB41-02 and R1G225-AF11-52 DC fans with backward curved impellers. Papst industrial cooling fans are used in cabinets and electronics.

Replacements should match the part number exactly, as size, voltage, airflow, speed signal and connector can differ between versions. EC fans can be speed controlled to save energy and reduce noise.

Where ebm-papst fans are used

Cooling of drives, UPS, telecom and control cabinets, HVAC units and electronic equipment.

ebm-papst products we list

Family Examples
Cooling R1G175-AB41-02 DC Fan, R1G225-AF11-52 DC Fan
Automation Accessories Papst Industrial Cooling Fan

Ordering ebm-papst fans: what we need

Send the full part number from the label, voltage and quantity.

Facts checked against ebm-papst's published company history, October 2026.

FAQ

Questions about the ebm-papst 8556 N AC Axial Panel Fan 80 mm 230 V

Answers from our engineering team on installation, compatibility and integration.

01What temperature range does the ebm-papst 8556 N support?
The datasheet allows minus 40 to plus 90 degrees C ambient, a very wide range for an 80 mm panel fan.
02What are the electrical data of the ebm-papst 8556 N?
It is a single phase AC fan for 230 VAC and 50 Hz, running at 2800 rpm with 12 W power consumption.
03How big is the 8556 N and how much air does it move?
The frame is 80 x 80 x 38 mm, weight 0.490 kg, and air flow is 50 m3/h with 31 dB(A) sound pressure level.
04What is the service life of the 8556 N?
L10 life is 52500 hours at 40 degrees C and 15000 hours at the maximum temperature.
05Which direction does the 8556 N blow?
The datasheet states exhaust over struts, so the air leaves past the struts on the outlet side of the fan.