Brand: Bürkert
Bürkert 316526 Type 8605 Proportional Valve Controller M12
Description
Overview
The Bürkert 316526 is the M12-connector, higher-current version of the Bürkert Type 8605 proportional valve controller: a plug-on electronics module with operating unit that supplies a PWM current of 500 to 2000 mA. Seven Star LLC is an independent supplier serving Oman and the GCC. Where the PG-gland variants hard-wire a cable, this one uses a 5-pin M12 connection, so the cable can be unplugged in seconds for valve replacement.
What changes with 500 to 2000 mA
The current range selects which coils the electronics can drive. The lower range of 200 to 1000 mA covers small valves; the 500 to 2000 mA range is for coils that need more current to reach full flow, such as the 24 V DC and 12 V DC versions of the larger proportional valve types in the compatibility table, including types 2865, 2875, 2861, 2871, 6024 and 6223. If a valve is listed for both ranges, the datasheet advises using the smaller one for better resolution.
Facts for Bürkert 316526
| Item | Value |
|---|---|
| Article number | Bürkert 316526 |
| Output signal | PWM, frequency adjustable 80 Hz to 6 kHz |
| Ramp function | time adjustable 0 to 10 s |
| Valve output current | maximum 2 A PWM |
| Operating voltage | 12 to 24 V DC, plus/minus 10 percent, residual ripple below 5 percent |
| Input signal | 0/4 to 20 mA or 0 to 5/10 V, configurable |
| Input impedance | below 200 ohm (current), above 20 kilohm (voltage) |
| Power consumption | approx. 1 W without valve |
| Housing material | polyamide / PC |
| Degree of protection | IP65 (cable plug variants) |
| Ambient temperature | minus 10 to plus 60 degrees C |
| Minimum valve load | 7 ohm; lower resistance damages the electronics |
| Variant | cable plug with M12 connection, with operating unit, coil current 500 to 2000 mA |
How Bürkert 316526 differs from other Type 8605 variants
Its twin with PG gland and the same range is 316529; without the operating unit the same range is 316525 (M12) and 316523 (PG). The lower-current M12 version with operating unit is 316528. The Bürkert 316526 therefore combines the pluggable M12 connection, the display and keys and the high-current range, making it the most flexible member of the group for service-friendly installations.
Where it is used
Typical uses include proportional dosing valves with larger coils, gas flow control in burners and furnaces and pressure control loops on test rigs. In industrial sites across the GCC, pluggable M12 wiring is popular because contractors can pre-assemble cables and valve replacement does not need a screwdriver or electrician. The unit is designed for IP65 operation when the plug is properly fitted.
Set-up
Mount the plug on the coil, fit the M12 cable and apply 12 to 24 V DC. With the keys select the signal type, then the minimum and maximum current. Adjust the PWM frequency between 80 Hz and 6 kHz depending on the valve; lower frequencies give more dither and can reduce hysteresis, while higher frequencies give quieter operation. Set the ramp time between 0 and 10 seconds to protect the process.
Verify the flow at three set-point values after tuning, and write the settings on the machine documentation.
Care
Check the M12 connector for corrosion and tighten the coupling nut after thermal cycles. Keep the cable shielded and routed away from power cables. If the valve is replaced by a different type, redo the current settings.
Response time and control logic
The switching times in the datasheet are measured under defined conditions, typically at 20 degrees C and a stated pressure with a stated outlet condition. In the field, tube length, cylinder volume and supply pressure change the effective response of the whole circuit far more than the valve alone. When a sequence depends on timing, measure the actual response with a pressure sensor or a stopwatch in the finished system and adjust timers or sensors accordingly. If two valves must act together, use identical numbers and equal tube lengths so that their delays match. Keep a margin in the control logic so that normal ageing does not push the sequence out of its tolerance.
Common wiring mistakes
Field experience shows a few wiring errors that account for most call-outs on newly installed valves. A plug that is not seated fully leaves the contacts intermittent and lets water into the housing. A cable gland tightened onto a damaged cable can pinch a conductor and cause a short only when the machine vibrates. Mixed-up polarity on a DC coil with a protection diode simply stops the valve from working. Control cabinets sometimes have a fuse that is too large for the coil, so a fault in one valve takes out a whole group of outputs. A short checklist covering seating, gland, polarity and fuse rating, followed by a continuity test, removes the large majority of these problems before start-up.
Environmental conditions in the Gulf
Equipment installed in Oman and the other Gulf countries faces heat, dust, salt and humidity, often in the same location. Direct sunlight can heat a valve body well above the ambient air temperature, and a coil that is already warm from its own losses has less margin. Shade valves where possible, and keep enclosures ventilated. Sand and dust can enter plugs and manual overrides, so check seals regularly. Coastal sites add salt, which accelerates corrosion on exposed metal parts and screws, so materials and coatings should be chosen with this in mind. Air drying is also more demanding in humid coastal conditions.
Training and handover
When a new valve type is introduced to a plant, a short briefing for the maintenance team prevents mistakes later. Cover the article number system, how to read the nameplate, where the datasheet is stored, how to isolate and depressurise safely and what the typical failure signs look like. Provide a laminated sheet at the panel with the valve number, supply voltage and the expected behaviour on power loss. A plant that keeps this knowledge in the heads of a few engineers is vulnerable to staff changes, whereas written records and a small amount of training keep service quality constant across shifts.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | TI TMS320F28335PGFA Digital Signal Controller | All Bürkert products.
Before you order the Bürkert 316526
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Bürkert 316526 code on this page.
- The quotation for the Bürkert 316526 states the confirmed code and the lead time to site.
- The attached manufacturer datasheet covers the Bürkert 316526 ratings, dimensions and installation details.
- Delivery of the Bürkert 316526 is arranged to project sites in Oman and across the GCC, alongside the rest of our controllers & data acquisition range.
- A spare Bürkert 316526 on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The Type 8605 datasheet is attached with the ordering chart and the valve compatibility matrix. Send your RFQ with Bürkert 316526, the quantity and delivery location in Oman or the GCC.
Other Models in the 8605 Range
Seven Star LLC supplies models from the 8605 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 316530 Type 8605 Proportional Valve Controller PG Gland | Controllers & Data Acquisition | View details |
| Bürkert 316526 Type 8605 Proportional Valve Controller M12 | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 316526 Type 8605 Proportional Valve Controller M12 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 316526 Type 8605 Proportional Valve
Answers from our engineering team on installation, compatibility and integration.
01What connector does the Bürkert 316526 use?
A 5-pin M12 connection, in a cable plug housing with operating unit.
02What current range does the Bürkert 316526 cover?
The 500 to 2000 mA range for coils that need more current than the small-coil range.
03How does the 316526 differ from the 316529?
Both are the 500 to 2000 mA variant with operating unit, but 316526 uses an M12 connection and 316529 a PG cable gland.
04What PWM frequency can be set on the Bürkert 316526?
The frequency is adjustable between 80 Hz and 6 kHz, with a ramp time of 0 to 10 seconds.
05What supply does the Bürkert 316526 need?
12 to 24 V DC with plus/minus 10 percent tolerance and residual ripple below 5 percent.