Brand: Katronic
Katronic KATflow 180 Gas Clamp-On Ultrasonic Flowmeter
Description
Overview
Measuring gas flow without cutting the pipe sounds like a trick, and for years it was close to impossible, because gas damps ultrasound so strongly. The Katronic KATflow 180 is Katronic’s clamp-on ultrasonic flowmeter for gases, using shear wave and Lamb wave transducers that stay on the outside of the pipe wall. It reads from atmospheric pressure up to unlimited maximum pressure, with flow velocities from 0.1 to 75 m/s, on pipes from 25 mm to 1,500 mm. Seven Star LLC is an independent supplier serving Oman and the GCC. The unit comes in non-Ex and ATEX versions for use in hazardous areas.
How the Katronic KATflow 180 measures gas
Standard transit-time meters use shear wave sensors, which only work in higher pressure gas lines. For lower pressure, the Lamb wave method excites the pipe wall at its resonance frequency so that the wall itself becomes both transmitter and receiver, and the active area is several times the length of the transducer. The meter uses digital signal processors, adaptive filtering and correlation transit-time evaluation to cope with changes in temperature, pressure and gas composition. The measurement rate is 100 Hz as standard.
Technical data of Katronic KATflow 180
| Parameter | Datasheet value |
|---|---|
| Principle | Ultrasonic correlation transit-time difference |
| Pipe diameter range | 25 mm to 1,500 mm |
| Flow velocity | 0.1 to 75 m/s |
| Turn down ratio | 1/200 (0.35 to 75 m/s) |
| Repeatability | 0.15 percent of measured value plus or minus 0.015 m/s |
| Accuracy | Plus or minus 1 to 3 percent of measured value, volume flow |
| Pressure range | 1 bar absolute to unlimited |
| Liquid content of gas | Less than 5 percent of volume |
| Enclosure | IP 66 field housing, copper-free aluminium, stainless steel optional |
| Ex code (enclosure) | II 2G Ex db eb IIB T6, EPS 11 ATEX 1355 X |
| Display | OLED graphic, 128 x 64 dots, backlit |
| Power supply | 100 to 240 V AC, 50/60 Hz, or 9 to 36 V DC; under 25 W |
| Operating temperature | minus 20 to plus 60 degrees C |
| Communication | Modbus RTU or Modbus TCP/IP |
| Outputs | 0/4-20 mA, open collector, relay, 0-10 V, frequency to 10 kHz, HART compatible |
| Gas normalisation | AGA8 or GERG |
Transducers for the Katronic KATflow 180
The G5 transducer works at 500 kHz and the G10 at 1 MHz, with stainless steel heads, PTFE cable conduits, a standard cable length of 10 m and IP 68 protection. Non-Ex versions operate from minus 20 to plus 135 degrees C, and Ex versions from minus 40 to plus 80 degrees C. The Ex transducers carry the code II 2G Ex mb IIC T6 Gb with certificate ZELM 04 ATEX 0212 X, and are approved for Zones 1 and 2. They connect directly to the flowmeter, or through extension cables and Ex-approved junction boxes.
How the Katronic KATflow 180 differs from the KATflow 150 and 100
The KATflow 150 is a liquid meter with a polycarbonate wall housing, one or two channels, a pipe range of 10 to 6,500 mm and a velocity limit of 25 m/s. The KATflow 180 is purpose-built for gases, with one channel, an aluminium Ex-capable housing, an OLED display and a velocity range up to 75 m/s. It also draws up to 25 W against under 10 W for the 150, and offers Modbus TCP/IP, which the 150 datasheet does not list.
Gas applications in Oman and the GCC
The datasheet names natural gas pipelines, gas storage, compressor station control, sour gas, synthesised gas and compressed air. These are everyday duties for oil and gas, LNG and industrial gas operators in the region. Clamp-on measurement allows checking of fuel gas lines, flare headers and utility air without shutdowns or hot tapping. Media listed include air, argon, carbon monoxide, ethane, ethylene, helium, hydrogen, natural gas, nitrogen, nitrous oxide, oxygen, process gas, propane, saturated steam and sour gas.
Configuration code and selection
The order code defines the number of channels, the supply of 100 to 240 V AC or 9 to 36 V DC, the enclosure type (non-Ex aluminium, Ex aluminium or Ex stainless steel), the communication option, the combination of inputs and outputs and the data logger. Outputs and inputs include active or passive current, open collector, relay, HART compatible, voltage, frequency, Pt 100 and current inputs for pressure, temperature or gas compressibility. A logger with 30,000 measurements is selectable. Because the code is built per project, supply the pipe data, gas and area class.
Installation and commissioning
Fit the mounting frame or rail to the clean pipe wall, mount the transducers in the arrangement the parameter menu proposes for the pipe, apply couplant as instructed, connect the cables and power up. Enter pipe diameter, wall thickness, material, gas and process conditions. Compare the measured velocity with the expected one, and use the signal quality indicators to fine tune sensor spacing. Access can be wired, wireless or through GSM for remote set-up and web-based data evaluation.
Maintenance
The meter has no parts in the gas stream, so maintenance is mostly inspection of cables, connectors and mounting frames, plus periodic verification of the readings against a reference.
Why clamp-on gas measurement saves shutdowns
An insertion or in-line gas meter normally needs a spool piece, a hot tap or a plant shutdown, plus blowdown and purging of a pipe that may hold flammable or sour gas. A clamp-on meter avoids all of it, because the transducers sit on the outside of the wall and the process never opens. For verification of a fiscal meter, balance checks across compressor stations or temporary surveys of a utility air header, the work can be done in hours with a permit, without disturbing production. Since the sensors carry no moving parts, there is nothing to foul, wear or plug, and sour gas does not attack the measuring system. Pipe wall condition still matters, so inspect the surface for scale, paint build-up and corrosion where the transducers will sit.
For permanent installations, add the sensor protection covers and the metallic rail described in the mounting accessories for the DN 25 to 250 and DN 80 to 1,500 ranges.
Ordering notes for Katronic KATflow 180
Provide the pipe outside diameter, wall thickness and material, the gas composition, the pressure and temperature range, and the area classification, so the correct transducers, enclosure and options can be selected.
Related items you may also need: Katronic KATflow 230 Portable Dual-Channel Clamp-On Ultrasonic Flow Meter | Katronic KATflow 200 Hand-Held Clamp-On Ultrasonic Flow Meter | Katronic KATflow 170 Explosion-Proof Clamp-On Ultrasonic Flow Meter | All Katronic products.
Documents and quotation
The manufacturer datasheet for the Katronic KATflow 180 is attached to this page. Send your RFQ with the model, configuration, quantity and delivery location in Oman or the GCC.
Other Models in the KATflow Range
Seven Star LLC supplies models from the KATflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Katronic KATflow 150 Advanced Clamp-On Ultrasonic Flowmeter | Ultrasonic Flowmeters | View details |
| Katronic KATflow 180 Gas Clamp-On Ultrasonic Flowmeter | Ultrasonic Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Katronic KATflow 180 Gas Clamp-On Ultrasonic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Katronic Technologies is a British manufacturer of clamp-on ultrasonic flow meters, based in Coventry. Founded in 1996 as a distributor of process measurement instruments with a focus on ultrasonics, it went on to design and make its own KATflow range. Its fixed, portable and explosion-proof meters measure liquid flow from outside the pipe.
Seven Star LLC is an independent supplier in Muscat. We list Katronic flowmeters for water, process and HVAC users in Oman and the GCC.
Katronic company profile
| Founded | 1996, England |
|---|---|
| Headquarters | Coventry, England |
| Technology | Clamp-on transit-time ultrasonic |
| Product families | KATflow 100 and 150 fixed meters, KATflow 170 explosion-proof meters, KATflow 200 and 230 portable meters |
Katronic product series
Fixed meters include the KATflow 100 clamp-on meter and the KATflow 170 explosion-proof meter.
Portable meters include the KATflow 200 hand-held meter and the KATflow 230 dual-channel meter.
Clamp-on meters measure flow from outside the pipe using transit-time ultrasound, so there is no pressure drop and no need to stop the process. Accuracy depends on the pipe data, straight run and transducer mounting.
Portable meters are used for flow surveys and checking fixed meters, while fixed meters provide continuous measurement with outputs to control systems.
Where Katronic flowmeters are used
Flow measurement without cutting the pipe in water networks, chilled water, process lines, hydrocarbons and flow surveys.
Katronic products we list
| Family | Examples |
|---|---|
| Flowmeters | KATflow 100 Clamp-On Ultrasonic Flow Meter, KATflow 170 Explosion-Proof Clamp-On Ult…, KATflow 200 Hand-Held Clamp-On Ultrasoni…, KATflow 230 Portable Dual-Channel Clamp-… |
Ordering Katronic flowmeters: what we need
Send the model, pipe size and material, liquid, temperature, outputs and any hazardous-area needs.
Facts checked against Katronic directory listings and WWEM exhibitor profile, October 2026.
Browse Katronic products by category: Flowmeters.
FAQ
Questions about the Katronic KATflow 180 Gas Clamp-On Ultrasonic
Answers from our engineering team on installation, compatibility and integration.
01What gases can the Katronic KATflow 180 measure?
The datasheet lists air, argon, carbon monoxide, ethane, ethylene, helium, hydrogen, natural gas, nitrogen, nitrous oxide, oxygen, process gas, propane, saturated steam and sour gas.
02What pipe sizes does the Katronic KATflow 180 cover?
It covers pipe diameters from 25 mm to 1,500 mm, with flow velocities from 0.1 to 75 m/s and pressure from 1 bar absolute upwards.
03Is the Katronic KATflow 180 available for hazardous areas?
Yes. The Ex enclosure is marked II 2G Ex db eb IIB T6, and the Ex transducers are approved for Zones 1 and 2.
04Which communication options does the Katronic KATflow 180 offer?
Modbus RTU or Modbus TCP/IP, plus remote access over Ethernet, wireless or GSM and a data logger holding 30,000 measurements.
05How does the Katronic KATflow 180 measure through the pipe wall?
It uses shear wave and Lamb wave clamp-on transducers with correlation transit-time evaluation, so the pipe does not need to be cut.