EUCHNER RPS-C-538SR95M Rope Pull Emergency Stop Switch

Description

Overview

Along a conveyor several hundred metres long, a single emergency stop button is useless to someone fifty metres away. The EUCHNER RPS-C-538SR95M solves that by turning a rope into a continuous emergency stop: pull the rope anywhere along its length and the switch trips. It is a compact plastic rope pull switch with a pull-to-reset button, an emergency stop detent in line with EN ISO 13850 and EN 60947-5-5, and two positively driven contacts in a 538 slow-action block. Seven Star LLC is an independent supplier serving Oman and the GCC.

Meaning of the code EUCHNER RPS-C-538SR95M

RPS is the rope pull switch range and the letter C marks the compact plastic version. The digits 538 give the switching element, which is a slow-action block with two positively driven contacts. SR95 and M designate the connection and the M20 x 1.5 cable entry. The article number is 174757. Rope, eyebolts and pulleys are accessories and are not included.

Technical values for EUCHNER RPS-C-538SR95M

Parameter Data
Function Emergency stop rope pull switch with pull-to-reset button and detent
Contacts 538 slow-action, 2 positively driven contacts
Utilization category AC-15 3 A at 240 V; DC-13 1.5 A at 24 V
Thermal current / fuse 5 A / up to 4 A gG
Insulation / impulse voltage 400 V / 4 kV
Conditional short-circuit current 400 A, safety class II
Rope diameter 2 to 5 mm
Actuating force 95 N
Connection 1 x M20 x 1.5, conductor 0.34 to 1.5 square mm
Housing Reinforced thermoplastic, IP66 / IP67
Ambient / storage minus 30 to plus 75 / minus 40 to plus 80 degrees C
Mechanical life 100,000 cycles
B10D / mission time 200,000 cycles / 20 years

How EUCHNER RPS-C-538SR95M differs from other RPS-C variants

The compact range has only two codes. The RPS-C-2131SR95M uses a 2131 element with three positively driven contacts and one normally open contact and has a pull eyelet but no reset button, so it is not an emergency stop device on its own. The EUCHNER RPS-C-538SR95M has two positively driven contacts, a detent and a reset by button, which is the arrangement required for the emergency stop function. Compared with the larger RPS models, the compact housing has a lower mechanical life of 100,000 cycles but a very wide temperature range from minus 30 to plus 75 degrees C.

Where rope pull switches are used in Oman and the GCC

Port and mining conveyors, aggregate plants, cement works, bulk material handling, airport baggage systems and long production lines all use rope pull switches. They are also placed along walkways of crushers and screening plants, where an operator may need to stop the machine from any point. Extremes of heat make the high upper temperature limit of 75 degrees C welcome, and the IP66 and IP67 ratings handle dust and washdown.

Rope installation

A switch at each end of the rope gives the best protection, so that a break at either end or a pull from any point trips the circuit. Use a rope between 2 and 5 mm in diameter, fit eyebolts, pulleys and a quick release head from the accessory range, and tension the rope as set out in the manual. The actuating force of 95 N is chosen so that a person can trip the rope easily but wind or vibration will not. Take care that the rope runs freely through the pulleys and is not obstructed by cable trays or guards.

Wiring

Connect both positively driven contacts to the emergency stop inputs of a safety relay, and use cable glands for 6 to 12 mm cables on the M20 x 1.5 entry. Conductors of 0.34 to 1.5 square mm may be used, with a fuse of at most 4 A gG. Because the switch has a detent, the reset must be made by pulling the button at the switch itself, which means someone must walk to the unit to find out why it tripped.

Dimensioning the rope run

Every rope installation needs a short calculation before the first pulley is fixed. The pull required to trip the EUCHNER RPS-C-538SR95M is 95 N, and the rope must be able to travel far enough, with allowance for sag and thermal expansion, for the detent to be reached from the farthest point of the run. In hot climates a long rope can lengthen in the afternoon sun, so tension adjusters are recommended at the end fittings. Support the rope at regular intervals with pulleys so that the sag stays small, and keep it clear of anything that could catch it or rub it through.

A rope pull switch is meant to be operated by a person’s pull in an emergency, so mount the rope at a height reachable from walkways and keep the rope visible, preferably with coloured sleeves. Warning signs near the rope and a clear label on the switch showing the reset procedure help the maintenance staff understand what has happened when the system has tripped.

Electrical considerations

The thermal rated current of 5 A and the conditional short-circuit current of 400 A reflect a robust build, but the contacts carry the low current of a safety relay input in most designs. The two positively driven contacts allow a dual-channel connection with monitoring of short circuits between channels. Where several rope switches serve one conveyor, connect them in series into the same safety input, and test each one individually so that a fault at a single switch can be isolated quickly.

Maintenance and testing

Pull the rope at several points along its length at regular intervals and check that the machine stops, that the switch latches and that the reset works. Look for fraying, corrosion and rope sag, check the eyebolts and pulleys and examine the housing for cracks. Keep the area around the switch free of dust build-up. Mission time is 20 years, but harsh sites may need earlier replacement of the rope and accessories.

Ordering notes

State the full code and the rope length of your installation, so that a suitable rope set, pulleys and eyebolts can be quoted at the same time. The ropes themselves are accessories. We can also quote cable glands.

Related items you may also need: EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set | EUCHNER ESM-BT411 Safety Relay with Time-Delayed Contacts | EUCHNER TX1B-A024M Guard Locking Safety Switch | All EUCHNER products.

Documents and quotation

The operating instructions for the rope pull switch family are attached to this page. Send your RFQ with EUCHNER RPS-C-538SR95M, the quantity and the delivery destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet EUCHNER RPS-C-538SR95M Rope Pull Emergency Stop Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER RPS-C-538SR95M Rope Pull Emergency Stop

Answers from our engineering team on installation, compatibility and integration.

01What is the purpose of the EUCHNER RPS-C-538SR95M?
It is a rope pull switch for emergency stop use: pulling the rope anywhere along its length trips the two positively driven contacts and latches.
02What rope diameter suits the EUCHNER RPS-C-538SR95M?
The manufacturer states a rope diameter of 2 to 5 mm and an actuating force of 95 N.
03What protection and temperature range does the RPS-C-538SR95M have?
It is rated IP66 and IP67, with an ambient range of minus 30 to plus 75 degrees C and a plastic housing.
04How does the RPS-C-538SR95M differ from the RPS-C-2131SR95M?
The 538 version has two positively driven contacts and a pull-to-reset button with detent, while the 2131 version has four contacts and a pull eyelet.
05Which accessories does the RPS-C-538SR95M need?
The rope, eyebolts, pulleys and quick release heads are accessories that are ordered separately, along with cable glands for the M20 x 1.5 entry.