Brand: Bürkert
Bürkert 560403 Type 8032 SE32 4-20 mA Flow Transmitter
Description
Overview
Bürkert 560403 turns the Bürkert Type 8032 into a flow transmitter. The SE32 electronics produce a galvanically isolated 4 to 20 mA signal proportional to flow, show flow on an 8-digit backlit display and connect through a free positionable 5-pin M12 male connector. The measuring element is a paddle wheel in a Type S030 Inline fitting. Seven Star LLC is an independent supplier serving Oman and the GCC.
The 4 to 20 mA loop of Bürkert 560403
The process value output is isolated and can drive a loop of up to 1300 ohms at 36 V DC, 1000 ohms at 30 V DC, 700 ohms at 24 V DC, 450 ohms at 18 V DC and 200 ohms at 12 V DC. Its uncertainty is plus or minus 0.5 percent of the current range, and the response time from 10 to 90 percent is 3 seconds with the default filter setting 2. The scale between 4 mA and 20 mA is set from the keys, so the span suits the line instead of the full 1000 l/min of the sensor.
Technical data for Bürkert 560403
| Parameter | Value |
|---|---|
| Article | 560403, SE32 transmitter, 4 to 20 mA, no UL |
| Output | 4 to 20 mA, galvanically isolated |
| Output uncertainty | plus or minus 0.5 percent of range |
| Response time | 3 s at filter 2 |
| Electrical connection | Free positionable 5-pin M12 male connector |
| UL approval | No (UL Recognized version is 570487) |
| Principle | Paddle wheel with 8-digit backlit LCD |
| Supply | 12 to 36 V DC plus or minus 10 percent, SELV and LPS, reverse-polarity protected |
| Current consumption | 80 mA or less with no load |
| Flow range | 0.5 to 1000 l/min, 0.3 to 10 m/s with Type S030 fitting |
| Deviation | teach-in plus or minus 1 percent; standard K factor plus or minus 3 percent |
| Linearity and repeatability | 0.5 percent of full scale; 0.4 percent of reading |
| Operating mode | threshold with window or hysteresis |
| Pipe size | DN 06 to DN 65 |
| Viscosity and solids | 300 cSt max.; up to 1 percent solids, 0.5 mm |
| Fluid temperature with S030 | PVC 0 to 50; PP 0 to 80; PVDF, steel or brass minus 15 to plus 100 degrees C |
| Fluid pressure | plastic PN 10, metal PN 16 |
| Housing | glass fibre reinforced PC, polyester front film |
Where Bürkert 560403 sits among Type 8032 transmitters
Two other transmitter articles exist: 560402 combines the 4 to 20 mA signal with a relay output and a 5-pin M12 connector, and 560547 does the same with an 8-pin M12 connector. 560403 has the analogue signal only, so it is the right choice when the PLC does the alarming and only a flow signal is needed. Threshold detectors without analogue output have the numbers 434871, 436473, 436474 and 436475.
Why a display on the sensor still helps
The 8-digit backlit LCD on the module shows flow rate or total, and three keys allow the operator to change thresholds and units on site. This saves a trip to the control room during commissioning and gives operators a local indication when the PLC link is lost. A teach-in routine lets you fill a known volume and correct the K factor, improving accuracy from plus or minus 3 percent with the default factor to plus or minus 1 percent at the teach-in flow.
Troubleshooting
If the display shows zero while liquid is moving, check that the pipe is full, that the paddle wheel turns freely and that the electronics are fully seated. If the reading jumps, look for air entrainment, a nearby control valve or pump pulsation. If the output does not switch, check the supply voltage at the connector under load, since long cables drop volts, then check wiring polarity and the switching mode. Wheel bearings of ceramic last long, but scale or fibres can block them and need cleaning.
Where the signal goes
The 4 to 20 mA signal is read by PLC analogue cards, chart recorders, panel meters and controllers such as multiCELL units. It suits flow control in cooling water, dosing loops and process water balances. Add loop surge protection on long outdoor cable runs, which are common in large Gulf sites.
Scaling the 4-20 mA signal of Bürkert 560403
The 4 to 20 mA range is set from the module menu so that 4 mA corresponds to a chosen low flow and 20 mA to a chosen high flow. For good resolution, choose the span close to the real operating range: a line that never exceeds 200 litres per minute should not be scaled to 1000. In the PLC, convert the current to flow using the same span. Add a low-flow cut-off so that noise at standstill does not produce phantom flow, and use the filter setting to damp pulsating flow from piston pumps.
The galvanic isolation of the output means the device can be used with grounded and floating loops alike, and protects PLC cards from ground loops.
Quotation notes for Bürkert 560403
Please give the article number, the quantity, the pipe size and fitting material, and the M12 connector length. The female M12 connector is not included. Tell us whether the measurement is for a billing, process control or monitoring task, so that we can advise on accuracy and installation. Delivery to Oman and the GCC will be planned from the details.
Typical measuring points
Common measuring points include chilled water circulation, boiler feed, process water supply to a reactor, spray water on a conveyor washer and chemical dosing lines, all within the range of 0.5 to 1000 l/min.
Delivery notes for Bürkert 560403
The module is delivered with its M12 male connector, and the female connector and Inline fitting are separate articles. The data sheet attached to this page contains the dimension drawings, the pin assignment and the pressure-temperature diagrams. Mention any need for UL approval or special documents when you ask for a quotation so that the correct article is offered.
Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Elster IRM-3 DUO Rotary Gas Meter DN100 to DN200 | All Bürkert products.
Documents and quotation
The Type 8032 data sheet containing Bürkert 560403 is attached with ordering information and dimensions. Send an RFQ with part number 560403, quantity and delivery location in Oman or the GCC, and add pipe size and material for the Inline fitting.
Other Models in the 8032 Range
Seven Star LLC supplies models from the 8032 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 434871 Type 8032 SE32 PNP Flow Threshold Detector | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 436473 Type 8032 SE32 Dual Output Flow Detector | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 560403 Type 8032 SE32 4-20 mA Flow Transmitter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 560403 Type 8032 SE32 4-20 mA Flow Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 560403 Type 8032 SE32 4-20 mA Flow
Answers from our engineering team on installation, compatibility and integration.
01What signal does Bürkert 560403 output?
It provides a galvanically isolated 4 to 20 mA process value output with an uncertainty of plus or minus 0.5 percent of the range.
02What loop impedance is allowed for 560403?
At 24 V DC the loop may reach 700 ohms, and at 36 V DC 1300 ohms, according to the data sheet.
03Does Bürkert 560403 include a relay?
No. The 4 to 20 mA plus relay versions are 560402 and 560547; this article has the analogue output only.
04What is the UL version of 560403?
The UL Recognized equivalent is listed as article 570487 in the Type 8032 ordering chart.
05How fast does 560403 respond?
The response time from 10 to 90 percent is 3 seconds with the default filter setting.