Brand: Bürkert
Bürkert 449694 Type 8030-HT SE30 High Temperature Flow Sensor
Description
Overview
Hot water, condensate and heated process liquids are beyond the reach of standard plastic-fitted flow sensors, and that is the gap Bürkert 449694 fills. It is the high temperature SE30-HT version of the Bürkert Type 8030 flowmeter electronics. A coil transducer replaces the Hall element, the paddle wheel is made of stainless steel 316L, and the fluid temperature limit rises to plus 125 degrees C. Seven Star LLC is an independent supplier serving Oman and the GCC.
Specification of Bürkert 449694
| Parameter | Value |
|---|---|
| Article | 449694, SE30-HT high temperature variant |
| Transducer | Coil, frequency output |
| Supply | 12 to 36 V DC plus or minus 10 percent; 35 V DC maximum outdoors or in humid places |
| Current consumption | 10 mA or less with no load |
| Outputs | 2 transistors, NPN and PNP, open collector, max. 700 mA |
| Frequency | 0 to 250 Hz, duty cycle 1/2 plus or minus 10 percent |
| Flow range | 0.85 to 1000 l/min, 0.5 to 10 m/s |
| Fluid temperature | minus 15 to plus 125 degrees C |
| Fluid pressure | PN 40 up to 90 degrees C; PN 25 from 90 to 125 degrees C |
| Ambient temperature | minus 15 to plus 80 degrees C |
| Housing | Glass fibre reinforced PPS with bayonet system |
| Wetted parts | Stainless steel armature, 316L paddle wheel, Iglidur bearing |
| Fitting | Inline sensor-fitting Type S030-HT, stainless steel |
Why the coil transducer matters in Bürkert 449694
A Hall element is sensitive to temperature, so for hot fluids the high temperature version uses a coil that picks up the change of magnetic field from the passing wheel blades. The signal is still a pulse train whose frequency follows the speed of the wheel, and a K factor converts it to flow. The outputs are protected against overvoltage, polarity reversal and short circuit, and can switch up to 700 mA, much more than the 100 mA of the Hall variant, so smaller relays or counters can often be driven directly.
How Bürkert 449694 differs from Bürkert 423913 and Bürkert 423914
Compared with the Hall article 423913, the HT variant widens the fluid range from 100 to 125 degrees C and raises the pressure rating to PN 40 at moderate temperature, but its minimum flow is 0.85 l/min rather than 0.5 l/min and its maximum frequency is 250 Hz instead of 300 Hz. Compared with Low Power article 423914 it needs its own supply and delivers two outputs. It requires the stainless steel Type S030-HT fitting with internal or external thread or weld ends.
Typical uses
Hot cooling water, hot water for cleaning, boiler condensate return, heated process water and thermal oil circuits at moderate viscosity are typical applications. In the Gulf, sun-heated water lines and hot washdown systems often exceed the limit of ordinary plastic fittings, making the stainless HT version a safer choice.
Straight run and installation position
Paddle wheel meters are sensitive to disturbed flow. Allow a straight inlet of at least ten pipe diameters after elbows or reducers, and a longer run after pumps or partly closed valves, with five diameters on the outlet side. The pipe must be full and free of air bubbles, so install in a rising line or a low point. Avoid mounting at the top of a horizontal pipe where air can collect, and keep solids below 1 percent by volume with a maximum particle size of 0.5 mm. Fluid viscosity should not exceed 300 cSt.
Environment and wiring
The device is rated for indoor and outdoor use up to 2000 m altitude, with relative humidity up to 80 percent without condensation. IP65 applies only when the device is wired and the cable plug is mounted and tightened. Use shielded cable up to 50 m long with external wire diameter of 5 to 8 mm and wire cross section of 0.25 to 1.5 mm2, rated above 80 degrees C. Protect the electronics from ultraviolet radiation when installed outdoors, for example with a shade. The supply should be an SELV limited power source.
Installation notes for Bürkert 449694
Weld or thread the S030-HT fitting into the line, allow it to cool after welding before inserting the electronics, and fasten the bayonet. Support the pipe near the fitting to prevent loading. Check that the line pressure and temperature stay within the pressure-temperature diagram for the HT variant, and install a pressure relief where thermal expansion could trap liquid.
Planning a hot service installation with Bürkert 449694
Hot water lines expand, and a rigid pipe fixed at both ends puts stress on any fitting. Provide expansion loops or flexible sections upstream and downstream, and avoid locating the sensor close to a pump discharge, where turbulence and pressure pulsation reduce accuracy. In steam condensate return lines, make sure flashing does not occur at the sensor, because vapour bubbles disturb the paddle wheel and produce false readings. Insulate the pipe but leave the electronics free so that they stay within the ambient limit of 80 degrees C.
Keep a record of the line temperature and pressure for comparison against the pressure-temperature diagram of the data sheet during commissioning, and set high-temperature alarms in the control system for protection of the fitting.
Wiring and protection of Bürkert 449694
The output stage is protected against overvoltage, polarity reversal and short circuit, so wiring errors during commissioning do not usually destroy it. Even so, power the sensor only after the cable plug is correctly wired and fully tightened, and use a limited power source as required by the data sheet. When the unit is mounted outdoors or in humid conditions, limit the supply voltage to 35 V DC rather than 36 V DC, as noted for the HT variant.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Veeder-Root EMR4 Electronic Meter Register | All Bürkert products.
Documents and quotation
The Type 8030 data sheet that lists Bürkert 449694 is attached with dimensions, ordering table and pressure-temperature diagrams. Send an RFQ with part number 449694, quantity and delivery location in Oman or the GCC, and mention pipe size for the matching HT fitting.
Other Models in the 8030 Range
Seven Star LLC supplies models from the 8030 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 423913 Type 8030 SE30 Hall Paddle Wheel Flow Sensor | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 449694 Type 8030-HT SE30 High Temperature Flow Sensor | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 449694 Type 8030-HT SE30 High Temperature Flow Sensor Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 449694 Type 8030-HT SE30 High Temperature
Answers from our engineering team on installation, compatibility and integration.
01What temperature can Bürkert 449694 handle?
The high temperature variant is rated for fluid temperatures from minus 15 to plus 125 degrees C with a stainless steel Inline fitting.
02What outputs does 449694 provide?
It has two NPN and PNP open-collector transistor outputs, up to 700 mA each, with frequency from 0 to 250 Hz.
03What is the pressure rating of Bürkert 449694?
The data sheet gives PN 40 up to 90 degrees C and PN 25 between 90 and 125 degrees C for this variant.
04What flow range does 449694 cover?
The range is 0.85 to 1000 l/min or 0.5 to 10 m/s, depending on the Type S030-HT fitting size.
05Which fitting does Bürkert 449694 need?
It mounts in the stainless steel Inline sensor-fitting Type S030-HT, which must be ordered separately with the thread or weld ends needed.