Bürkert 569259 Type 8619 multiCELL Modbus TCP Controller

Description

Overview

Plants that talk Modbus TCP over Ethernet can use Bürkert 569259, the Type 8619 multiCELL base unit with an Ethernet module. It keeps the two flow inputs, two transistor outputs and two 4 to 20 mA outputs of the standard flow version and adds two RJ45 ports so that flow data and setpoints travel over the plant network. This article is delivered with the Modbus TCP protocol and is not UL approved. Seven Star LLC is an independent supplier serving Oman and the GCC.

Network features of Bürkert 569259

  • Two RJ45 ports on the Ethernet module for line or star topologies.
  • Modbus TCP supported by this article; PROFINET Conformance Class B and EtherNet/IP are available only in sibling articles.
  • Shielded FTP cable of at least category 5e, up to 100 m per segment.
  • Two yellow link and activity LEDs per port.
  • Module power of 2.2 VA, which is why the Ethernet variant allows up to 4 A on four output modules.

Specification of Bürkert 569259

Parameter Value
Article 569259, flow measurement plus 1 Ethernet module
Protocol Modbus TCP
Connection 2 x RJ45, connector not supplied
Cable FTP, category 5e or better, max. 100 m
Digital inputs 2, 0.5 to 2500 Hz
Outputs 2 transistor, 2 x 4 to 20 mA
UL approval No
Housing Panel-mounted multiCELL, 1/4 DIN, 92 x 92 mm cutout, PPO housing
Supply 12 to 36 V DC plus or minus 10 percent, max. 2 A, via external SELV and LPS supply
Power consumption max. 1.5 VA for the main module alone
Display LC graphic display, 128 x 168 pixels, light blue backlight, English, German, French
Keys 4 soft keys and 1 central navigation key
Module slots 6
Data logger up to 16 values, SD or SDHC card up to 8 GB
Ambient temperature minus 10 to plus 70 degrees C with main module only; up to plus 60 degrees C with an additional module
Protection IP65 or NEMA 250 4X in front of a closed cabinet; IP20 behind the panel
Altitude and humidity max. 2000 m, below 85 percent without condensation

Choosing between Bürkert 569259 and its network siblings

The ordering chart lists three Ethernet articles for the flow layout: 569259 for Modbus TCP, 569260 for PROFINET and 569261 for EtherNet/IP with UL. A device ordered with Modbus TCP does not contain the other two protocols; if you later want PROFINET or EtherNet/IP, the data sheet says that the Ethernet protocol option must be ordered separately. Devices ordered with PROFINET or EtherNet/IP contain all three. Check the PLC platform before ordering.

Typical network use

A SCADA or PLC polls flow rate and totals through Modbus registers and writes setpoints for dosing outputs, removing the need for analogue wiring back to a remote I and O rack. This suits packaged water treatment units and skid systems that must be integrated by a main contractor with a standard Ethernet network.

Power supply, wiring and EMC practice

The multiCELL expects a filtered and regulated 12 to 36 V DC supply from an external limited power source. Use cable rated for more than 90 degrees C, with cross sections of 0.2 to 1.5 mm2 on the terminal strip and 0.75 to 1.5 mm2 for the earth conductor. Strip insulation to 7 mm, use ferrules where possible, and keep shielded signal cable away from motor and drive cables. Where the unit is installed outdoors or in a humid place, the maximum voltage allowed drops by one volt according to the data sheet notes for the wall variant, so confirm the supply setting before energising.

Power distribution terminals marked PWR OUT can feed external loads up to 1.8 A at the supply voltage with polarity protection, which saves a separate supply for small sensors.

Why module-based design helps spares planning

The multiCELL is configured at the factory with up to five module types in six slots: an input module, an output module, a pH and ORP module, a conductivity module and an Ethernet module. That means an article number really describes a combination, and a spare device cannot simply be re-configured in the field. For critical plants, hold a spare of the exact article rather than a nearby one, and record the module configuration printed on the nameplate in the plant asset register.

Standards and approvals worth checking

The multiCELL carries CE conformity and is available in UL Listed and UL Recognized versions for the USA and Canada, selected by a separate article number in each row of the ordering chart. If your project specification demands UL, pick the matching UL article rather than assuming the non-UL one is covered. The device is designed for continuous operation, fixed installation, pollution degree 2 and installation category I, and is intended for indoor and outdoor use within the stated temperature and humidity limits.

Troubleshooting guide

If the display shows no flow although the process is running, check the sensor supply, the digital input threshold of 5 volts or higher and the frequency range of 0.5 to 2500 Hz. If a loop output stays at 4 mA, check the loop impedance against the limits quoted for the supply voltage and confirm that the output is configured as source or sink to match the receiving device. If values freeze when a memory card is inserted, try the tested Bürkert card, because untested cards may not work reliably.

Network commissioning

Assign a static IP address, subnet mask and gateway from the device menu, connect an RJ45 cable from a managed switch, and check link LEDs. Map Modbus registers to the PLC and watch data refresh. Keep Ethernet cables separate from power lines and use shielded patch cords with metal connectors earthed at the cabinet.

Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Chromalox 6140 / 4140 Temperature and Process Controller | All Bürkert products.

Documents and quotation

The Type 8619 data sheet covering Bürkert 569259 is attached with its ordering chart and network details. Send an RFQ with part number 569259, quantity and delivery location in Oman or the GCC.

Other Models in the 8619 Range

Seven Star LLC supplies models from the 8619 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 560205 Type 8619 multiCELL Flow Transmitter ControllerControllers & Data AcquisitionView details
Bürkert 560200 Type 8619 multiCELL pH/ORP ControllerControllers & Data AcquisitionView details
Bürkert 560201 Type 8619 multiCELL Conductivity ControllerControllers & Data AcquisitionView details
Bürkert 569259 Type 8619 multiCELL Modbus TCP ControllerControllers & Data AcquisitionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 569259 Type 8619 multiCELL Modbus TCP Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 569259 Type 8619 multiCELL Modbus TCP

Answers from our engineering team on installation, compatibility and integration.

01Which protocol does Bürkert 569259 support?
This article is delivered with Modbus TCP over its Ethernet module; PROFINET and EtherNet/IP articles have different numbers.
02How many Ethernet ports has 569259?
The Ethernet module has two RJ45 ports, and the connectors and cable must be supplied separately.
03Does Bürkert 569259 measure flow?
Yes, the configuration is the flow measurement base unit with two digital inputs plus the Ethernet module.
04What cable length is allowed for 569259?
The data sheet requires shielded FTP cable of at least category 5e with a maximum length of 100 m.
05Is 569259 UL approved?
No, 569259 is listed without UL approval, while the EtherNet/IP article of the same layout is listed with UL.