Brand:

Viking Pump KK4924A Ammonia Refrigeration Gear Pump 30 GPM

Description

Overview

Viking Pump KK4924A is a cast iron internal gear pump built specifically for refrigeration ammonia recirculation. It delivers 30 GPM (113.5 LPM) at up to 280 rpm through 2 inch NPT ports, and is part of the 4924A Series, which replaced the earlier 4925 Series. Instead of a single seal, it uses a pair of mechanical seals with a pressurised barrier oil system, so that ammonia is contained safely even if the inboard seal starts to leak. Seven Star LLC is an independent supplier serving Oman and the GCC.

Ammonia plants in cold stores, food and beverage factories, and process cooling systems use pumps like this to circulate liquid ammonia from the receiver to the evaporators and back.

Safety design of the Viking Pump KK4924A

The double mechanical seals have carbon graphite rotating faces against Ni-Resist stationary seats. Ni-Resist is a metallic face that can be replaced without the risk of hairline cracks sometimes caused when fitting ceramic or silicon carbide seats. Between the inboard and outboard seals the chamber is filled with refrigeration oil supplied from a reservoir mounted above the pump. A flush line with a valve carries ammonia from behind the rotor into the reservoir, so the barrier oil is pressurised to the same pressure as the seal sees inside the pump, and the outboard seal sees oil only.

The manufacturer contrasts this with sealless magnetic drive pumps, which need recirculation through the canister area to remove eddy-current heat and are therefore less efficient. A return-to-tank pressure relief valve is standard, so ammonia from an overpressure event is sent back to the tank.

Specification table

Parameter Value
Model Viking Pump KK4924A, 4924A Series, cast iron, double mechanical seal
Port size 2 inch NPT
Nominal capacity 30 GPM (113.5 LPM)
Maximum speed 280 rpm
Maximum differential pressure 50 PSIG (3.5 bar)
Minimum temperature, catalog pump -20 F (-29 C); down to -40 F (-40 C) if oil in the seal chamber is heated
Series maximum temperature 225 F (105 C)
Shipping weight with relief valve and reservoir 140 lb (64 kg)
Casing, head and bracket Cast iron, ASTM A48 Class 35B
Rotor and idler Cast iron, ASTM A48 Class 35B
Shaft Steel, ASTM A434 Type 4140 Grade BC or equivalent
Idler pin Hardened steel, ASTM A108 Grade 10L45
Seals Double mechanical, carbon graphite versus Ni-Resist
Relief valve Return-to-tank type, standard

How KK4924A differs from other 4924A variants

The 4924A Series has five sizes. HL4924A moves 10 GPM (37.8 LPM) at 780 rpm through 1.5 inch ports and weighs 70 lb (32 kg). K4924A moves 20 GPM (75.7 LPM) at 280 rpm and weighs 135 lb (62 kg). Viking Pump KK4924A moves 30 GPM and weighs 140 lb (64 kg). LQ4924A moves 45 GPM (170 LPM) through 2.5 inch flanged ports and weighs 215 lb (98 kg), and LL4924A moves 60 GPM (227 LPM) through 3 inch flanged ports at 230 lb (105 kg). All have the same 50 PSIG differential limit.

Applications for KK4924A

The Gulf region has a large demand for cold chain infrastructure, and ammonia remains common in large installations because of its efficiency. Cold stores and food plants in the Gulf, ice and dairy plants, breweries and process chillers use ammonia refrigeration. The pump is used for liquid transfer and recirculation, but it is a specialist device and should be installed by refrigeration engineers following recognised refrigeration safety practice and local codes.

Options available for Viking Pump KK4924A

Cold rooms create two practical problems for ammonia pumps: frost obscures the oil sight glass, and cold oil thickens in the seal chamber. The options below address both problems. Each is specified at the time of order, so tell us if the pump will sit in a low-temperature area or if oil must be topped up while the plant is running.

  • Sight glass with frost shield, so the oil level remains visible in cold rooms.
  • Filling valve for adding oil while the pump runs.
  • Oil reservoir heater, an electric immersion type for pumps installed in cold rooms.

End clearance and maintenance

The 4924A replaced the 4925 series with a simpler end clearance adjustment: the bearing housing on the bracket is rotated clockwise until it stops and then backed off by the distance given in the technical service manual before locking. This avoids removing bearing end caps and measuring with a feeler gauge, so it can be done without taking the pump out of service. Check the barrier oil level through the sight glass at each round and top up with refrigeration oil.

Installation notes

Mount the oil reservoir above the pump so that gravity maintains barrier pressure, keep the flush line with its valve accessible, and ensure that oil levels are checked at commissioning. Size the suction piping one size larger than the pump port, as recommended in the catalog, and keep it short and free of traps. Route the relief valve return to the tank, use oil compatible with the refrigeration system and check the reservoir connections for leaks before filling with ammonia. Only qualified personnel should commission ammonia equipment, and the plant safety case should cover the pump, relief return and oil system. Pressure test the oil circuit and verify the sight glass reading before introducing refrigerant, then compare the oil level again after the first hours of operation to confirm the barrier system is pressurised as intended.

Related items you may also need: KRACHT KP 1/4 K10Q M0A 4NL1 High-Pressure Gear Pump | Debem Equaflux 100 Pulsation Damper for AODD Pumps | VERDERAIR VA50 Metallic Air-Operated Double Diaphragm Pump | All Viking Pump products.

Before you order the Viking Pump KK4924A

  • To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Viking Pump KK4924A code on this page.
  • The quotation for the Viking Pump KK4924A states the confirmed code and the lead time to site.
  • The attached manufacturer datasheet covers the Viking Pump KK4924A ratings, dimensions and installation details.

Documents and quotation

The attached catalog section covers the 4924A Series ammonia pumps. To request a quotation for Viking Pump KK4924A, send the code Viking Pump KK4924A and quantity through the RFQ form, together with the operating temperature and any options such as the heater or filling valve.

Datasheets & Documents
  • PDF Datasheet Viking Pump KK4924A Ammonia Refrigeration Gear Pump 30 GPM Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.

FAQ

Questions about the Viking Pump KK4924A Ammonia Refrigeration Gear Pump

Answers from our engineering team on installation, compatibility and integration.

01What is the capacity of the KK4924A?
KK4924A delivers 30 GPM (113.5 LPM) at a maximum speed of 280 rpm through 2 inch NPT ports.
02How does the KK4924A seal ammonia?
It uses double mechanical seals with carbon graphite faces against Ni-Resist seats, with the space between them filled with pressurised refrigeration oil from an elevated reservoir.
03What is the pressure limit of the KK4924A?
The catalog lists 50 PSIG (3.5 bar) maximum differential pressure for all sizes in the series.
04Can the KK4924A run in a cold room?
The catalog pump is rated to minus 20 F (minus 29 C), and to minus 40 F (minus 40 C) if heat is provided to the seal chamber oil, for example with the optional reservoir heater.
05How heavy is the KK4924A?
The shipping weight with pressure relief valve and reservoir is 140 lb (64 kg).