EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12 8-Pin
Description
Overview
The EUCHNER CES-I-BR-U-C07-SA is a transponder-coded safety switch from EUCHNER for monitoring movable guards such as doors, hatches and covers. It reads an RFID actuator through its active face, carries two redundant semiconductor safety outputs and adds a separate door position monitoring output. Its order number is 157920. The small plastic housing measures 40 x 26.5 x 18 mm, so it fits into narrow aluminium profile frames where a larger switch would not. Seven Star LLC is an independent supplier serving Oman and the GCC.
How the EUCHNER CES-I-BR-U-C07-SA detects the actuator
The U in the type code means unicode evaluation. Each actuator is individually coded, and the switch accepts only an actuator that has been taught in. More actuators can be taught later, but only the last taught actuator is recognised, which stops a lost or bypassed actuator from still working after replacement. This highly coded approach is what makes the switch suitable for applications where tampering protection matters.
Safety characteristics of EUCHNER CES-I-BR-U-C07-SA
- Two redundant semiconductor safety outputs FO1A and FO1B with internal monitoring
- Suitable for Category 4 and PL e to EN ISO 13849-1, and SIL 3 to EN IEC 62061
- PFH value of 6 x 10 to the minus 10 per hour, mission time 20 years
- Output test pulses of 0.3 ms about every 100 ms to detect short circuits
- Series connection of several devices possible through enable inputs FI1A and FI1B
Technical data for EUCHNER CES-I-BR-U-C07-SA
| Parameter | Value |
|---|---|
| Operating voltage | 24 V DC, minus 15 to plus 15 percent, regulated |
| Current consumption | 40 mA |
| Safety outputs | p-switching semiconductor, short-circuit proof, up to 150 mA, DC-13 at 24 V |
| Monitoring output OD/C | p-switching, 1 to 50 mA |
| Risk time | max. 125 ms, plus 10 ms for each additional device |
| Turn-on time of safety outputs | max. 100 ms |
| Ready delay | 5 s |
| Switching frequency | max. 1 Hz |
| Connection | M12 plug, 8-pin; tightening torque max. 0.8 Nm |
| Dimensions | 40 x 26.5 x 18 mm |
| Housing material | Plastic PBT-PC-GF30 |
| Degree of protection | IP65, IP67, IP69 and IP69K |
| Ambient temperature | minus 25 to plus 55 degrees C (65 degrees C at max. 10 mA per safety output) |
| Mounting | Surface mounting on metal, any orientation, 50 mm minimum between switches |
| Operating altitude | up to 4,000 m |
Pin assignment of the EUCHNER CES-I-BR-U-C07-SA
The eight-pin M12 plug assigns pin 1 to enable input channel B, pin 2 to the 24 V DC supply, pin 3 and pin 4 to the safety outputs FO1A and FO1B, pin 5 to the monitoring output and communication line, pin 6 to enable input channel A, pin 7 to 0 V and pin 8 as not connected. Wire the plug exactly as shown, because reversing the safety outputs and enable inputs defeats the series connection logic.
How the EUCHNER CES-I-BR-U-C07-SA differs from other CES-I-BR variants
EUCHNER builds the CES-I-BR-.-C07 family with different evaluation modes and output options. The U in this code selects unicode teach-in, in contrast with multicode types that do not compare the full actuator code. The SA ending identifies the version with the door position monitoring output on pin 5, and versions with an N suffix, such as CES-I-BR-U-C07-SA-N, are listed separately by EUCHNER under another order number. The typical operating distances depend on the actuator: with the CES-A-BDN-06 the switch-on distance is 16 mm in installation position A and 11 mm in position C, while with CES-A-BTN-C07 it is 13 mm in positions A and B and 7 mm in positions C and D.
Applications in Oman and the GCC
Machine builders in packaging, bottling, food processing and general assembly use compact RFID switches like this one on swing doors and sliding guards, while plant owners fit them on robot cell fences and conveyor access points. IP69K protection suits washdown zones in food factories, and the plastic housing resists corrosion in humid coastal conditions.
Mounting and commissioning
Surface-mount the switch on a metal frame, keep at least 50 mm between neighbouring switches, and maintain a side clearance of 6 mm so the actuator does not enter the side lobes of the actuating range. After wiring, teach in the actuator by following the procedure in the operating instructions, then verify the safety function with the door open and closed and check the diagnostic and status LEDs. Remember that the actuator is not included and must be ordered separately.
Selection tips
Pick this version when you want tamper-resistant coding, a compact body and a plug connector for quick replacement. Before ordering, decide which actuator fits the door geometry, because the actuating range changes with actuator type, substrate material and approach direction, and check that the controller can read an OSSD pair with test pulses.
Maintenance
Check mounting screws, caps over the mounting holes and the M12 connector for tightness at each inspection, and keep the actuating face free from metal chips. Test the protective function periodically as required by your risk assessment.
Series connection and diagnostics
The enable inputs allow several switches to be chained so that one pair of safety channels covers a whole line of guards. Each additional device adds up to 10 ms to the risk time, which the safety designer has to include when calculating stopping distances. The STATE and DIA indicators on the housing show whether the actuator is detected and whether a fault is present, and the monitoring output on pin 5 signals the door position to the controller without being part of the safety function. Use the output only for indication, never as a replacement for the safety outputs.
Related items you may also need: EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | EUCHNER CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety Switch | EUCHNER CTP-I-AP-U-HA-ZZ-SA Safety Switch without Guard Locking | All EUCHNER products.
Documents and quotation
The operating instructions for the EUCHNER CES-I-BR-U-C07-SA are attached to this page and contain wiring, teach-in steps and safety data. Send your RFQ with EUCHNER CES-I-BR-U-C07-SA, the actuator you need and the quantity, together with the delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12 8-Pin Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12
Answers from our engineering team on installation, compatibility and integration.
01What is the order number of the EUCHNER CES-I-BR-U-C07-SA?
The EUCHNER order number is 157920 for the CES-I-BR-U-C07-SA with an eight-pin M12 plug connector and a door position monitoring output.
02What safety level does the CES-I-BR-U-C07-SA reach?
The two redundant semiconductor outputs allow Category 4 and PL e to EN ISO 13849-1 and SIL 3 to EN IEC 62061, with a PFH value of 6 x 10 to the minus 10 per hour.
03Is the actuator included with the CES-I-BR-U-C07-SA?
No. The actuator is not included, so you must order it separately, for example the CES-A-BTN-C07 or CES-A-BDN-06 listed in the data.
04What does unicode mean for this EUCHNER switch?
Each actuator has a unique code and the switch detects only the actuator that was taught in; only the last taught actuator is recognised.
05What supply and outputs does the CES-I-BR-U-C07-SA need?
It runs on 24 V DC with 15 percent tolerance and 40 mA draw, with two safety outputs of up to 150 mA and a monitoring output of 1 to 50 mA.