Brand:

EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12 8-Pin

Description

Overview

The EUCHNER CES-I-BR-U-C07-SA is a transponder-coded safety switch from EUCHNER for monitoring movable guards such as doors, hatches and covers. It reads an RFID actuator through its active face, carries two redundant semiconductor safety outputs and adds a separate door position monitoring output. Its order number is 157920. The small plastic housing measures 40 x 26.5 x 18 mm, so it fits into narrow aluminium profile frames where a larger switch would not. Seven Star LLC is an independent supplier serving Oman and the GCC.

How the EUCHNER CES-I-BR-U-C07-SA detects the actuator

The U in the type code means unicode evaluation. Each actuator is individually coded, and the switch accepts only an actuator that has been taught in. More actuators can be taught later, but only the last taught actuator is recognised, which stops a lost or bypassed actuator from still working after replacement. This highly coded approach is what makes the switch suitable for applications where tampering protection matters.

Safety characteristics of EUCHNER CES-I-BR-U-C07-SA

  • Two redundant semiconductor safety outputs FO1A and FO1B with internal monitoring
  • Suitable for Category 4 and PL e to EN ISO 13849-1, and SIL 3 to EN IEC 62061
  • PFH value of 6 x 10 to the minus 10 per hour, mission time 20 years
  • Output test pulses of 0.3 ms about every 100 ms to detect short circuits
  • Series connection of several devices possible through enable inputs FI1A and FI1B

Technical data for EUCHNER CES-I-BR-U-C07-SA

Parameter Value
Operating voltage 24 V DC, minus 15 to plus 15 percent, regulated
Current consumption 40 mA
Safety outputs p-switching semiconductor, short-circuit proof, up to 150 mA, DC-13 at 24 V
Monitoring output OD/C p-switching, 1 to 50 mA
Risk time max. 125 ms, plus 10 ms for each additional device
Turn-on time of safety outputs max. 100 ms
Ready delay 5 s
Switching frequency max. 1 Hz
Connection M12 plug, 8-pin; tightening torque max. 0.8 Nm
Dimensions 40 x 26.5 x 18 mm
Housing material Plastic PBT-PC-GF30
Degree of protection IP65, IP67, IP69 and IP69K
Ambient temperature minus 25 to plus 55 degrees C (65 degrees C at max. 10 mA per safety output)
Mounting Surface mounting on metal, any orientation, 50 mm minimum between switches
Operating altitude up to 4,000 m

Pin assignment of the EUCHNER CES-I-BR-U-C07-SA

The eight-pin M12 plug assigns pin 1 to enable input channel B, pin 2 to the 24 V DC supply, pin 3 and pin 4 to the safety outputs FO1A and FO1B, pin 5 to the monitoring output and communication line, pin 6 to enable input channel A, pin 7 to 0 V and pin 8 as not connected. Wire the plug exactly as shown, because reversing the safety outputs and enable inputs defeats the series connection logic.

How the EUCHNER CES-I-BR-U-C07-SA differs from other CES-I-BR variants

EUCHNER builds the CES-I-BR-.-C07 family with different evaluation modes and output options. The U in this code selects unicode teach-in, in contrast with multicode types that do not compare the full actuator code. The SA ending identifies the version with the door position monitoring output on pin 5, and versions with an N suffix, such as CES-I-BR-U-C07-SA-N, are listed separately by EUCHNER under another order number. The typical operating distances depend on the actuator: with the CES-A-BDN-06 the switch-on distance is 16 mm in installation position A and 11 mm in position C, while with CES-A-BTN-C07 it is 13 mm in positions A and B and 7 mm in positions C and D.

Applications in Oman and the GCC

Machine builders in packaging, bottling, food processing and general assembly use compact RFID switches like this one on swing doors and sliding guards, while plant owners fit them on robot cell fences and conveyor access points. IP69K protection suits washdown zones in food factories, and the plastic housing resists corrosion in humid coastal conditions.

Mounting and commissioning

Surface-mount the switch on a metal frame, keep at least 50 mm between neighbouring switches, and maintain a side clearance of 6 mm so the actuator does not enter the side lobes of the actuating range. After wiring, teach in the actuator by following the procedure in the operating instructions, then verify the safety function with the door open and closed and check the diagnostic and status LEDs. Remember that the actuator is not included and must be ordered separately.

Selection tips

Pick this version when you want tamper-resistant coding, a compact body and a plug connector for quick replacement. Before ordering, decide which actuator fits the door geometry, because the actuating range changes with actuator type, substrate material and approach direction, and check that the controller can read an OSSD pair with test pulses.

Maintenance

Check mounting screws, caps over the mounting holes and the M12 connector for tightness at each inspection, and keep the actuating face free from metal chips. Test the protective function periodically as required by your risk assessment.

Series connection and diagnostics

The enable inputs allow several switches to be chained so that one pair of safety channels covers a whole line of guards. Each additional device adds up to 10 ms to the risk time, which the safety designer has to include when calculating stopping distances. The STATE and DIA indicators on the housing show whether the actuator is detected and whether a fault is present, and the monitoring output on pin 5 signals the door position to the controller without being part of the safety function. Use the output only for indication, never as a replacement for the safety outputs.

Related items you may also need: EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | EUCHNER CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety Switch | EUCHNER CTP-I-AP-U-HA-ZZ-SA Safety Switch without Guard Locking | All EUCHNER products.

Documents and quotation

The operating instructions for the EUCHNER CES-I-BR-U-C07-SA are attached to this page and contain wiring, teach-in steps and safety data. Send your RFQ with EUCHNER CES-I-BR-U-C07-SA, the actuator you need and the quantity, together with the delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12 8-Pin Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CES-I-BR-U-C07-SA RFID Safety Switch, M12

Answers from our engineering team on installation, compatibility and integration.

01What is the order number of the EUCHNER CES-I-BR-U-C07-SA?
The EUCHNER order number is 157920 for the CES-I-BR-U-C07-SA with an eight-pin M12 plug connector and a door position monitoring output.
02What safety level does the CES-I-BR-U-C07-SA reach?
The two redundant semiconductor outputs allow Category 4 and PL e to EN ISO 13849-1 and SIL 3 to EN IEC 62061, with a PFH value of 6 x 10 to the minus 10 per hour.
03Is the actuator included with the CES-I-BR-U-C07-SA?
No. The actuator is not included, so you must order it separately, for example the CES-A-BTN-C07 or CES-A-BDN-06 listed in the data.
04What does unicode mean for this EUCHNER switch?
Each actuator has a unique code and the switch detects only the actuator that was taught in; only the last taught actuator is recognised.
05What supply and outputs does the CES-I-BR-U-C07-SA need?
It runs on 24 V DC with 15 percent tolerance and 40 mA draw, with two safety outputs of up to 150 mA and a monitoring output of 1 to 50 mA.