Brand: Magnetrol
Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPT
Description
Magnetrol 089-9126-011: ATEX flameproof transducer kit for the Echotel 355
The Echotel 355 is better known for its intrinsically safe versions, but the manual also lists a flameproof (XP) version, and its transducer kit is Magnetrol 089-9126-011. It is the transducer replacement for a 355 with cast aluminum housing, 3/4 inch NPT conduits and a polypropylene transducer, in an ATEX flameproof and encapsulated unit.
Few suppliers list this kit because the ATEX XP version is the rarest of the 355 family: the parts table has ten aluminum-base kits, only two of them XP (089-9126-011 and 089-9126-012). That scarcity is exactly why a plant that owns such a unit tends to search by number. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of 089-9126-011
- Restores a flameproof Echotel 355 with aluminum housing.
- Polypropylene transducer with 2 inch NPT thread.
- 3/4 inch NPT conduit entries.
- Marked II 1/2 G Ex ma/db IIC T4 Ga/Gb in the approval table.
- One of only two XP kits in the aluminum-base list.
Technical specifications of 089-9126-011
| Parameter | Value |
|---|---|
| Part number | 089-9126-011 |
| Kit type | Transducer replacement kit, cast aluminum housing base |
| Approvals | ATEX XP (flameproof) |
| Conduit connections | 3/4 inch NPT |
| Transducer material | Polypropylene |
| Approval marking | II 1/2 G Ex ma/db IIC T4 Ga/Gb; IP66 |
| Ambient range | -40 to +70 C |
| Supply (XP) | 16 to 30 VDC in the manual caution; 6 to 30 VDC in the specification table |
| Echotel 355 transducer data | Value |
|---|---|
| Maximum range | 20 feet (6 m) under ideal conditions |
| Minimum range | 13 inches (330 mm) |
| Blocking distance | 10 inches (250 mm) |
| Frequency | 60 kHz |
| Beam angle | 10 degree conical |
| Process connection | 2 inch NPT |
| Process temperature | -40 to +175 F (-40 to +80 C) |
| Process pressure | 0 to 43.5 psig (0 to 3 bar) |
| Accuracy | Greater of 0.2 percent of range or 0.24 inch (6 mm) |
| Repeatability | 0.125 inch (3 mm) |
| Resolution | 0.1 inch (2.5 mm) |
| Output | 4 to 20 mA, optional HART, 3.8 to 20.5 mA usable (NAMUR NE 43) |
| Minimum measurement | 3 inches (76 mm) |
| Linearity | 0.4 inch (10 mm) |
| Response time | Less than 1 second, typical |
| Warm-up time | 25 seconds |
| Display | 2-line by 16-character LCD with 4-button keypad |
| Diagnostic alarm | Selectable 3.6 mA, 22 mA or HOLD |
| Power consumption | Less than 1 watt |
Typical uses of 089-9126-011 in oil and gas, utilities, water and manufacturing
A flameproof ultrasonic transmitter allows the instrument to be wired with ordinary flameproof glands and conduit in Zone 1 style locations, without a barrier. Typical Omani uses are tank farms, truck loading sumps, produced water tanks and effluent pits on oil and gas facilities.
The approval list in the manual describes the XP and encapsulation marking as II 1/2 G Ex ma/db IIC T4 Ga/Gb with IP66 for -40 to +70 C, with special conditions of use that the installer must read before putting the unit into service.
How 089-9126-011 differs from other Echotel 355 transducer kits
| Kit | Difference |
|---|---|
| 089-9126-007 | ATEX IS, 3/4 NPT, polypropylene |
| 089-9126-011 | ATEX XP, 3/4 NPT, polypropylene (this part) |
| 089-9126-012 | ATEX XP, M20, Kynar |
| 089-9126-009 | ATEX IS, M20, polypropylene |
The distinction from 089-9126-012 is both the conduit thread and the transducer plastic (3/4 inch NPT with polypropylene versus M20 with Kynar). The distinction from the intrinsically safe kits 089-9126-007 and 089-9126-009 is the protection concept, and mixing them would invalidate the approval label.
Selection and compatibility for 089-9126-011
- Housing: cast aluminum base only; the Lexan base has no XP kits in the manual.
- Conduits: 3/4 inch NPT.
- Approval: ATEX XP.
- Process connection: 2 inch NPT polypropylene transducer.
- Check that the flameproof joints are not repaired in the field; the manual says to consult the manufacturer if repair of the flamepath is necessary.
Practical notes for 089-9126-011
Flameproof wiring is simpler to maintain than barrier-based wiring when a plant has trained staff and certified glands, because the transmitter is supplied directly in the loop rather than through an associated apparatus. The manual still limits the supply voltage with a caution that the XP version operates from 16 to 30 VDC and that higher voltage will damage the unit.
Special conditions of use apply to the flameproof and encapsulated marking, and the installer should read the approval section of manual 51-661 before the unit is commissioned. The warm-up time after power is applied is 25 seconds, so wait for initialisation before judging the reading.
For a transmitter in a classified area, record the approval label, the ATEX certificate number FM20ATEX0028X and the IECEx certificate FMG 20.0030X that the manual cites, so that an inspector can match the replacement kit to the certified model.
Installation and commissioning of 089-9126-011
For a flameproof installation, the manual refers to its flameproof wiring section: wire with approved glands, keep covers fully engaged and never open the enclosure when the area is not known to be non-hazardous with power on.
Mount the transducer by hand only, with the face parallel to the liquid within 2 to 3 degrees and at least 10 inches above the highest level.
Maintenance and spares planning
Look at the cover threads and O-rings at each round, as the flamepath is part of the certified protection. Do not file, paint or damage the thread surfaces. Keep the kit 089-9126-011 labeled for ATEX XP use only.
Documents and quotation
The manufacturer manual 51-661 for the Echotel Model 355 is attached to this page as the datasheet for 089-9126-011; its section 3.4 holds the parts table and section 3.6 the specifications used above. To receive a quotation, send an RFQ giving part number 089-9126-011, quantity, the model number printed on the transmitter nameplate and the delivery location in Oman or the GCC.
Spares and Lifecycle Considerations
For critical service, many plants hold one Magnetrol 089-9126-011 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical ultrasonic level transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.
Other Models in the Magnetrol 355 Range
Seven Star LLC supplies models from the Magnetrol 355 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 089-9125-003 HART Electronic Module for Echotel 355 | Level Switches | View details |
| Magnetrol 089-9126-001 Echotel 355 Transducer Kit, Polypropylene | Level Switches | View details |
| Magnetrol 089-9126-016 Echotel 355 Transducer Kit Lexan FM M20 Kynar | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 Kynar | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PP | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPT | Ultrasonic Level Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPT Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 089-9126-011 Echotel 355 Transducer Kit
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol 089-9126-011?
It is the transducer replacement kit for an ATEX XP (flameproof) Echotel 355 with cast aluminum housing, 3/4 inch NPT conduits and a polypropylene transducer.
02Is there an M20 flameproof transducer kit?
Yes, 089-9126-012 is listed for ATEX XP with M20 conduits and a Kynar Flex transducer.
03What is the ATEX marking for the flameproof 355?
The manual lists II 1/2 G Ex ma/db IIC T4 Ga/Gb, IP66, for -40 to +70 C ambient.
04Can the flameproof joint be repaired on site?
The manual says the flamepaths are not intended to be repaired and the manufacturer must be consulted.
05Can Seven Star LLC quote 089-9126-011?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.


















Reviews
There are no reviews yet.