- Automation & ControlView all 3,043 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Magnetrol
Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PP
Description
Magnetrol 089-9126-009: ATEX intrinsically safe transducer kit for the Echotel 355
When a gas plant buys level instruments for tanks where flammable vapor can be present, the approval on the transmitter matters as much as the range. The Magnetrol 089-9126-009 replaces the transducer on an Echotel 355 with ATEX intrinsically safe approval, an aluminum housing, M20 conduits and a polypropylene face.
The ATEX marking quoted in the manual for the intrinsically safe version is II 1 G Ex ia IIC T4 Ga with IP67, valid for -40 to +70 C ambient, and the instrument is on the IECEx scheme as well. Using a kit with the same approval keeps the loop certificate valid, which is why the approval is part of the part number rather than a separate option. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of 089-9126-009
- Matches ATEX intrinsically safe Echotel 355 transmitters with aluminum housing.
- Polypropylene face with 2 inch NPT thread.
- M20 conduit entries.
- IP67 marking in the IS approval.
- Keeps the 60 kHz, 10 degree beam transducer data of the 355.
Technical specifications of 089-9126-009
| Parameter | Value |
|---|---|
| Part number | 089-9126-009 |
| Kit type | Transducer replacement kit, cast aluminum housing base |
| Approvals | ATEX intrinsically safe |
| Conduit connections | M20 |
| Transducer material | Polypropylene |
| ATEX marking (IS) | II 1 G Ex ia IIC T4 Ga; IP67 |
| Ambient range | -40 to +70 C under the approval |
| IS supply | 16 to 28.4 VDC, Vmax 28.4 V, Imax 94 mA, Pmax 0.67 W |
| Echotel 355 transducer data | Value |
|---|---|
| Maximum range | 20 feet (6 m) under ideal conditions |
| Minimum range | 13 inches (330 mm) |
| Blocking distance | 10 inches (250 mm) |
| Frequency | 60 kHz |
| Beam angle | 10 degree conical |
| Process connection | 2 inch NPT |
| Process temperature | -40 to +175 F (-40 to +80 C) |
| Process pressure | 0 to 43.5 psig (0 to 3 bar) |
| Accuracy | Greater of 0.2 percent of range or 0.24 inch (6 mm) |
| Repeatability | 0.125 inch (3 mm) |
| Resolution | 0.1 inch (2.5 mm) |
| Output | 4 to 20 mA, optional HART, 3.8 to 20.5 mA usable (NAMUR NE 43) |
| Minimum measurement | 3 inches (76 mm) |
| Linearity | 0.4 inch (10 mm) |
| Response time | Less than 1 second, typical |
| Warm-up time | 25 seconds |
| Display | 2-line by 16-character LCD with 4-button keypad |
| Diagnostic alarm | Selectable 3.6 mA, 22 mA or HOLD |
| Power consumption | Less than 1 watt |
Typical uses of 089-9126-009 in oil and gas, utilities, water and manufacturing
Polypropylene is the lower-cost, more widely used transducer material for the 355, and is usually fine in water, wastewater and many fuels. In an Omani context, typical uses include sumps and storage tanks at pumping stations, diesel day tanks and fuel-oil tanks at power sites, with the ATEX IS version going where area classification requires it.
Because the IS loop has fixed entity parameters (Vmax 28.4 V DC, Imax 94 mA, Pmax 0.67 W, Ci 5.5 nF, Li 9.4 microhenry), the associated barrier or isolator must be checked against them when the transmitter is replaced or rewired.
How 089-9126-009 differs from other Echotel 355 transducer kits
| Kit | Difference |
|---|---|
| 089-9126-007 | ATEX IS, 3/4 NPT, polypropylene |
| 089-9126-008 | ATEX IS, 3/4 NPT, Kynar |
| 089-9126-009 | ATEX IS, M20, polypropylene (this part) |
| 089-9126-010 | ATEX IS, M20, Kynar |
| 089-9126-011 | ATEX XP, 3/4 NPT, polypropylene |
Versus 089-9126-004, this kit swaps the FM approval for ATEX and polypropylene for Kynar. Versus 089-9126-007 only the conduit thread differs (M20 instead of 3/4 inch NPT). Versus the XP kit 089-9126-011 the protection concept changes from intrinsic safety to flameproof, so wiring practice and the barrier arrangement change.
Selection and compatibility for 089-9126-009
- ATEX/IECEx intrinsically safe (agency code A) with aluminum housing and M20 conduits (housing code 1).
- Polypropylene transducer (code B, 2 inch NPT).
- For intrinsically safe wiring the supply range is 16 to 28.4 VDC.
- Confirm the nameplate approval before ordering.
Practical notes for 089-9126-009
Intrinsically safe devices keep the energy in the field circuit below the ignition level, so the calculation is done once for the loop: the barrier output must stay at or below Vmax 28.4 V, Imax 94 mA and Pmax 0.67 W for the 355, and the cable capacitance and inductance must be added to the instrument values Ci 5.5 nF and Li 9.4 microhenry.
Because the manual gives the IS supply window as 16 to 28.4 VDC and warns that a higher voltage will damage the transmitter, the loop supply selection should be verified after any replacement. A loop resistance of 400 ohm at 24 VDC and 20 mA is the figure the manual gives for the maximum load.
Installation and commissioning of 089-9126-009
Follow the intrinsically safe wiring diagram in section 2.4.2 of the manual, keep the shield grounded at the power supply end, and use 18 to 22 AWG shielded twisted pair rated for at least +85 C. Hand-tighten the transducer into the 2 inch NPT process connection only.
Check the supply with the unit in service: low loop voltage shows as the LowVDC@20mA message, and in that case the barrier or the cable run must be reviewed.
Maintenance and spares planning
Document the approval label and kit number in the hazardous area equipment register. Any repair of an intrinsically safe unit must restore the certified configuration, so keep kit 089-9126-009 for ATEX transmitters only and keep it separate from the FM-approved kits in the store.
Documents and quotation
The manufacturer manual 51-661 for the Echotel Model 355 is attached to this page as the datasheet for 089-9126-009; its section 3.4 holds the parts table and section 3.6 the specifications used above. To receive a quotation, send an RFQ giving part number 089-9126-009, quantity, the model number printed on the transmitter nameplate and the delivery location in Oman or the GCC.
Documentation and Compliance
Industrial buyers often need more than the hardware. When you order the Magnetrol 089-9126-009, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Magnetrol ultrasonic level transmitters items can be checked against the bill of materials quickly.
Other Models in the Magnetrol 355 Range
Seven Star LLC supplies models from the Magnetrol 355 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 089-9125-003 HART Electronic Module for Echotel 355 | Level Switches | View details |
| Magnetrol 089-9126-001 Echotel 355 Transducer Kit, Polypropylene | Level Switches | View details |
| Magnetrol 089-9126-016 Echotel 355 Transducer Kit Lexan FM M20 Kynar | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 Kynar | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PP | Ultrasonic Level Transmitters | You are viewing this model |
| Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPT | Ultrasonic Level Transmitters | View details |
Datasheets & Documents
- Datasheet Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PP Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 089-9126-009 Echotel 355 Transducer Kit
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol 089-9126-009?
It is the Echotel 355 transducer replacement kit for ATEX intrinsically safe units with an aluminum housing base, M20 conduits and a polypropylene transducer.
02What are the IS entity parameters of the 355?
The manual gives Vmax 28.4 VDC, Imax 94 mA, Pmax 0.67 W, Ci 5.5 nF and Li 9.4 microhenry.
03What is the supply range of an intrinsically safe 355?
The intrinsically safe supply is 16 to 28.4 VDC according to the manual.
04What is the XP version of this kit?
The ATEX XP kits are 089-9126-011 (3/4 inch NPT, polypropylene) and 089-9126-012 (M20, Kynar).
05Can Seven Star LLC supply 089-9126-009?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.


















Reviews
There are no reviews yet.