Brand: Magnetrol
Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay
Description
Magnetrol Z30-2086-010: hermetically sealed relay board for the Echotel 910
Most Echotel 910 boards use a gold flash relay with a rating of 8 A. Magnetrol Z30-2086-010 is the exception: a 24 VDC board with a hermetically sealed DPDT relay rated 5 A, and again with terminal blocks TB4 and TB5. It is the replacement for units ordered with the sealed relay option, and it is easy to confuse with Z30-2086-002 because the supply voltage is the same.
The reason to pay attention to the relay type is the environment around the contacts. A hermetically sealed relay keeps the contact chamber closed to humidity, dust and corrosive vapors, which is why instrument engineers choose it for humid, coastal or chemically polluted sites. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Facts that identify Z30-2086-010
- Supply: 24 VDC with plus or minus 10 percent tolerance.
- Output relay: hermetically sealed DPDT, 5 A at 24 VDC, 5 A at 120 VAC and 5 A at 240 VAC in the manual specification.
- Wiring: terminal blocks TB4 and TB5, not phono jacks.
- Part of item 1 in the manual replacement parts table, last of the terminal-block 24 VDC options.
Specification table for Z30-2086-010
| Parameter | Value |
|---|---|
| Part number | Z30-2086-010 |
| Supply | 24 VDC |
| Relay | Hermetically sealed DPDT, 5 A |
| Relay ratings | 5 A at 120 VAC, 5 A at 240 VAC, 5 A at 24 VDC |
| Power supply options | 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent) |
| Repeatability | 0.078 inch (2 mm) |
| Calibration | None required; set point not adjustable |
| Process (transducer) | -40 to +250 F (-40 to +121 C) |
| Shock / vibration | ANSI/ISA-S71.03 Class SA1 / VC2 |
| Process connection | 3/4 inch NPT, or 1 inch BSP |
Applications of Z30-2086-010 in oil and gas, utilities, water and manufacturing
Low-current signalling circuits, such as inputs to a PLC or a safety relay, benefit from sealed contacts because contact resistance stays stable over years. In Oman that matters on offshore-style platforms, desalination plant galleries and coastal pumping stations where salt-laden air gets into enclosures.
Typical duties are high-level protection on a drain sump or surge vessel, low-level cutoff on a lube-oil reservoir, and leak detection in secondary containment.
How Z30-2086-010 differs from the other terminal-block boards
| Board | Variant |
|---|---|
| Z30-2086-002 | 24 VDC, gold flash 8 A relay |
| Z30-2086-010 | 24 VDC, hermetically sealed 5 A relay (this part) |
| Z30-2086-011 | 120 VAC, hermetically sealed 5 A relay |
| Z30-2086-012 | 240 VAC, hermetically sealed 5 A relay |
The decision between 002 and 010 is a load question: if a contactor or heavy lamp must be driven directly, the 8 A relay is chosen; if the contact only passes signal current, the sealed 5 A relay is preferred. The difference of 3 A in rating is the whole story.
Selection checks for Z30-2086-010
- Read the relay type on the original board or the nameplate.
- Confirm the supply is 24 VDC.
- Check that the load stays within 5 A.
- Choose Z30-2043-010 instead if the transducer connects through phono jacks.
Installation notes for Z30-2086-010
After fitting the board, set the P1 fail-safe jumper for the action the process needs and test it by wetting and drying the transducer gap. The relay will change state each time, and the manual shows the contact positions for each jumper position and for wet and dry conditions.
Maintenance of Z30-2086-010
A sealed relay is not serviceable, so a worn contact means replacing the board. Because the O-ring 012-2101-345 keeps moisture from the whole electronics compartment, replace it at the same time if it looks flattened. Keep the removed board in antistatic packaging until the failure cause is understood.
Mechanical data of the Model 910 that carries Z30-2086-010
| Dimension | Value |
|---|---|
| Transducer thickness | Diameter 0.875 inch, which is 22 mm |
| Conduit and tank threads | Dual 3/4 inch NPT conduit entries; tank connection 3/4 inch NPT or 1 inch BSP |
| Drawing figures for the housing | 158 mm by 113 mm (6.25 by 4.48 inch), 117 mm diameter |
| Space needed to turn the housing | 87 mm (3.44 inch) |
| Actuation point on the drawing | 6 mm (0.25 inch) |
Approvals and conditions of use that apply to Z30-2086-010
Manual 51-604 states the approvals of the complete Model 910. They matter for a board replacement because the certified configuration must be restored.
| Item | Statement |
|---|---|
| T6 temperature code | Held only while the enclosure stays at or below 70 C |
| Probe pairing | The Echotel 910 transmitter is for use with the Echotel 910 probe only |
| FM and CSA listings | FM19US0170X and FM20CA0034X, Class I Div 1 Groups B, C, D and Class II, III Div 1 Groups E, F, G, Type 4X; non-incendive Div 2 at T5 |
| ATEX and IECEx | FM20ATEX0005X and FMG20.0004X, flameproof Ex db IIC T6 Gb, IP66 |
| Conductor note | At 70 C ambient, check the manufacturer guidance on conductor selection |
Additional characteristics of the Model 910 that the board serves are below.
| Characteristic | Value |
|---|---|
| Transducer tip | 316 stainless steel with epoxy-encapsulated crystals |
| Power supply options | 120 VAC or 240 VAC (+10/-15 percent), 50/60 Hz; 24 VDC (plus or minus 10 percent) |
| Calibration | None required; set point not adjustable |
| Ambient (electronics) | -40 to +158 F (-40 to +70 C) |
| Process (transducer) | -40 to +250 F (-40 to +121 C) |
| Housing | Aluminum sand cast, dual 3/4 inch NPT conduit entries |
| Process connection | 3/4 inch NPT, or 1 inch BSP |
Documents and quotation
The manufacturer manual 51-604 for the Echotel Model 910 is attached as the datasheet for Z30-2086-010, so the parts table, relay wiring table and specifications can be checked directly. To get a quotation, send an RFQ with part number Z30-2086-010, the quantity, the supply voltage and relay type printed on the Model 910 nameplate and the delivery location in Oman or the GCC. Quote the supply voltage and relay type with the part number, because the Model 910 boards differ in exactly those two characteristics.
Other Models in the Magnetrol 910 Range
Seven Star LLC supplies models from the Magnetrol 910 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z30-2086-003 Echotel 910 Relay PC Board 120 VAC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2043-003 Echotel 910 Phono Jack PC Board, 120 VAC | Level Switches | View details |
| Magnetrol Z30-2086-002 Echotel 910 PC Board 24 VDC 8A DPDT | Level Switches | View details |
| Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay | Level Switches | You are viewing this model |
Datasheets & Documents
- Datasheet Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC 5A Sealed Relay Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Z30-2086-010 Echotel 910 PC Board 24 VDC
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol Z30-2086-010?
It is the 24 VDC PC board with a hermetically sealed 5 A DPDT relay and terminal blocks TB4 and TB5 for the Echotel Model 910.
02How does it differ from Z30-2086-002?
The supply voltage is the same, but Z30-2086-002 has a gold flash 8 A relay and Z30-2086-010 has a hermetically sealed 5 A relay.
03What are the other sealed-relay boards?
Z30-2086-011 is the 120 VAC sealed relay board and Z30-2086-012 the 240 VAC sealed relay board.
04Is the Model 910 field adjustable?
No. The manual says field calibration is not required and the set point is fixed; only the fail-safe jumper and relay wiring are selected.
05Can Seven Star LLC quote Z30-2086-010?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.


















Reviews
There are no reviews yet.