Brand: Panametrics
Panametrics IQ.probe Aluminum Oxide Moisture Probe
Description
Panametrics IQ.probe overview
The Panametrics IQ.probe is an aluminum oxide moisture probe with an electronics module attached to the sensor. It couples to the Panametrics dew.IQ hygrometer through a simple twisted pair cable. The 16-bit electronics can detect changes of parts per billion in moisture concentration, are self-calibrating, and store the sensor calibration in nonvolatile EEPROM so the analyzer loads the data automatically.
For buyers in Oman and the wider Gulf, the IQ.probe is a part that is searched for by exact model name, because the equipment it belongs to often stays in service for many years. This page describes the IQ.probe aluminum oxide moisture probe using only information published by the manufacturer, so that you can confirm the model before you send a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the Panametrics IQ.probe
The manufacturer highlights the following points for the IQ.probe.
- Moisture measurement from ambient down to ppb levels.
- 16-bit resolution.
- Nonvolatile calibration data storage, with automatic data entry in the dew.IQ.
- Calibrations traceable to NIST or NPL.
- Needs only unshielded twisted pair AWG 22 cable, with the probe up to 3000 ft (914 m) from the analyzer.
- Process pressure from vacuum up to 5000 psig (345 bar) with no minimum flow.
- Sensor tolerates process temperature excursions up to 70 C.
Together these points explain why the IQ.probe remains a practical choice where the measurement must be dependable and where service access is limited. Each statement above comes from the published datasheet, and nothing has been added beyond it.
Technical specifications of the IQ.probe
| Parameter | Value |
|---|---|
| Sensor type | Aluminum oxide moisture sensor |
| Overall range capability | -110 to 60 C (-166 to 140 F) |
| Standard range | -80 to 20 C with data to -110 C |
| Ultra-low range | -110 to -50 C |
| High range data | -80 to 60 C |
| Calibrated accuracy at 25 C | 2 C above -100 C; 3 C below -100 C |
| Repeatability | 0.2 C above -100 C |
| Operating pressure | 5 micron Hg to 5000 psig (345 bar) |
| Gas flow | Static to 10,000 cm/s at 1 atm |
| Liquid flow | Static to 10 cm/s at 1 g/cc |
| Sensor operating temperature | -110 to 70 C (-166 to 158 F) |
| Electronics temperature | 0 to 60 C (32 to 140 F) |
| Separation from dew.IQ | 3000 ft (900 m) recommended maximum, AWG 22 twisted pair |
Values are taken from the manufacturer datasheet for the IQ.probe; always confirm against the current document, because ranges, certifications and options depend on the exact configuration that is ordered.
Typical applications for the IQ.probe in Oman and the GCC
The IQ.probe is applied in industrial gases, furnace and heat treating gas, power generation, compressed air dryers, pharmaceutical and aerospace gases, including utilities and plants in the GCC.
In oil and gas, the IQ.probe supports process monitoring where an accurate reading helps operators protect equipment and keep production stable. In utilities and water, it gives plant teams a measurement they can trust for balance and efficiency checks. In general manufacturing, it is used wherever the process fluid or gas has to be controlled closely. The hot climate and demanding duty of the region put extra weight on dependable instruments, so spare availability of the IQ.probe matters to maintenance planners.
Selection and compatibility notes for the IQ.probe
The IQ.probe is designed for gases and is paired with the dew.IQ analyzer. Choose the calibration range, standard, ultra-low or high range, at ordering. Keep the electronics module within 0 to 60 C even when the sensor sees colder process gas. For distances beyond 3000 ft, the manufacturer asks that you consult the factory.
If you are replacing an existing IQ.probe, the safest approach is to read the nameplate, note the full model code, serial number and any certification marking, and send those details with your enquiry. This avoids mismatches in mounting, connector or range, which are the most common causes of a replacement that does not fit.
Installation and commissioning of the IQ.probe
Follow the installation guide or user manual that belongs to your meter or analyzer. Before fitting the IQ.probe, check that the process conditions, including temperature, pressure and fluid, are inside the limits in the specification table. Confirm the cable or connector type, use the recommended wiring and keep signal cables away from power cabling. After mounting, verify the reading against a known reference or an expected process value and record the configuration so that later maintenance can repeat it. In hazardous areas, install only with the certified accessories and follow the local code of practice.
Maintenance and service life of the IQ.probe
Routine care for the IQ.probe consists of visual inspection of the connector, cable, seals and mounting hardware, checking the reading for drift or noise, and keeping the surface free of deposits where that applies to the design. Keep a spare on the shelf for critical measurements, since lead times for specialist parts can be long. Recalibration or exchange intervals should follow the manufacturer recommendation for the instrument system in which the IQ.probe operates.
Related products and ordering notes for the IQ.probe
The IQ.probe is one member of the wider Panametrics range of flow, moisture, oxygen and gas measurement equipment. Related items on this site include other Panametrics analyzers and flow meters. When ordering, give the exact part or model code, the quantity, the meter or analyzer it will connect to and the delivery location. Do not rely on the family name alone, because the IQ.probe family has several configurations.
Frequently asked questions about the IQ.probe
The questions below summarize what buyers most often ask about the Panametrics IQ.probe: what it is, where it is used, which conditions it handles and how to order a matching part. The answers are drawn from the published datasheet. For anything that depends on a specific configuration, send us the nameplate data and we will help confirm the match before quoting.
Documents and quotation
A manufacturer datasheet for the IQ.probe is attached to this page. To request a quotation, send the RFQ with the part number IQ.probe, the full model code from your nameplate and the quantity you need, and our team will respond with availability and lead time. IQ.probe enquiries from Oman and the GCC are welcome.
Datasheets & Documents
- Datasheet Panametrics IQ.probe Aluminum Oxide Moisture Probe Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics IQ.probe Aluminum Oxide Moisture Probe
Answers from our engineering team on installation, compatibility and integration.
01What is the Panametrics IQ.probe?
The Panametrics IQ.probe is a smart aluminum oxide moisture probe for dew.IQ hygrometers. It is described in the manufacturer datasheet referenced on this page.
02Where is the IQ.probe typically used?
The datasheet and application notes point to uses such as industrial gases and similar process duties.
03What are the key specifications of the IQ.probe?
Sensor type: Aluminum oxide moisture sensor; Overall range capability: -110 to 60 C (-166 to 140 F). See the specifications table for the full list.
04How do I make sure I order the correct IQ.probe?
Send the full model code, nameplate details and the instrument it connects to. Many Panametrics items are configured by code, so every field must match.
05Is Seven Star LLC affiliated with the manufacturer of the IQ.probe?
No. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number and quantity.


















Reviews
There are no reviews yet.