Brand:

Panametrics HygroPro RTE Replacement Transducer Element

Description

Panametrics HygroPro RTE replaceable transducer element overview

The Panametrics HygroPro RTE is the replaceable transducer element, or RTE, of the HygroPro aluminum oxide moisture transmitter. In the HygroPro design the transmitter has two parts: a display and keypad housing, and the RTE, which holds the aluminum oxide moisture sensor, a temperature thermistor, a pressure transducer and the associated electronics. When the sensor needs recalibration or has been fouled, the Panametrics HygroPro RTE is exchanged instead of the whole transmitter. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Because the calibration data for the moisture and pressure sensors are stored in non-volatile memory inside the element, the transmitter reads the data by itself when a new or recalibrated HygroPro RTE is installed, and the user does not key in any calibration constants.

What the HygroPro RTE contains

  • A thin-film aluminum oxide moisture sensor, individually computer-calibrated against known moisture concentrations traceable to NIST.
  • An NTC thermistor for process temperature, operating from -30 to 70 C with an overall accuracy of plus or minus 0.5 C.
  • A solid-state piezoresistive pressure transducer, built in so that pressure-dependent values can be calculated.
  • Electronics and a non-volatile EEPROM that stores the calibration data of the moisture and pressure sensors.

These elements are why the HygroPro RTE is treated as a calibrated assembly: it is calibrated at the factory and no evaluation is required after installation of a new probe.

Why replace the HygroPro RTE regularly

Panametrics recommends recalibration of the aluminum oxide sensor every six to twelve months, with the optimum interval depending on the application. There are two ways to do it: send the HygroPro RTE back for recalibration or install a new one. The field replacement is simple, because the element is released by removing a small mounting plate and disconnecting a cable. This approach shortens downtime on pipeline gas dryers, instrument air monitors and process gas lines, since a spare HygroPro RTE can be fitted while the removed unit is recalibrated.

The programmed probe calibration data should not be changed without consulting the manufacturer.

Specifications of the HygroPro system using the HygroPro RTE

Parameter Value
Sensor type Thin-film aluminum oxide moisture sensor
Standard calibration range (dew/frost point) +10 to -80 C, with data from +20 to -110 C
Moisture accuracy Plus or minus 2 C above -100 C; plus or minus 3 C below -100 C
Moisture repeatability Plus or minus 0.2 C above -100 C; plus or minus 0.5 C below -100 C
Flow rate Gases: static to 100 m/s linear velocity at 1 atm
Operating pressure 5 micrometre Hg to 5000 psig (345 bar)
Pressure ranges available 30 to 300, 50 to 500, 100 to 1000, 300 to 3000 and 500 to 5000 psig
Pressure accuracy Plus or minus 1 percent of full scale
Temperature sensor NTC thermistor, -30 to 70 C, plus or minus 0.5 C
Sample connection 3/4-16 inch straight male thread with O-ring; G 1/2 with optional adapter
Transmitter operating temperature -20 to 60 C
Output 4 to 20 mA analog and RS485 digital
Hazardous area C-US Class I Division 1 Groups A, B, C and D; ATEX II 1 G EEx ia IIC T4; IECEx Ex ia IIC T4

The datasheet publishes these values for the HygroPro as a whole. They describe the performance delivered by the transmitter fitted with a HygroPro RTE, and the exact pressure range depends on the element that was originally supplied.

Applications in Oman and GCC industry

Dew point control is essential for natural gas export lines, gas turbine fuel, instrument air systems, furnace and heat-treating gases, industrial gas production and petrochemical process streams. The HygroPro is suited to those services, and a spare HygroPro RTE keeps the transmitter in service during sensor recalibration. In the Sultanate and across the Gulf, trace moisture in natural gas can lead to hydrate formation and corrosion, so moisture monitors at dehydration units and custody transfer points are valuable.

Selection and compatibility notes for HygroPro RTE

Select the element to match the transmitter and the pressure range of the installation, because the HygroPro RTE includes the pressure transducer. State the transmitter model, serial number and original pressure range when ordering so the correct element is supplied. Check that the sample system fitting is 3/4-16 inch straight male thread or the G 1/2 adapter, and confirm that the sensor suits the process gas, as aluminum oxide sensors are meant for gases and non-aqueous liquids.

Replacing the HygroPro RTE

  • Isolate the sample and unthread the transmitter from the fitting with a 1-1/8 inch wrench on the probe hex nut.
  • Disconnect the cable, remove the metal plate with its four captive screws and withdraw the old element without touching the sensor.
  • Reconnect the cable to the new element by turning the locknut and push it carefully into the transmitter.
  • Refit the plate, tighten the four screws, reinstall the transmitter and check that the readings are plausible against ambient air.

Cleaning and care

The user manual describes a cleaning sequence for the sensor: soak in hexane or toluene for ten minutes, soak in distilled water for ten minutes, then soak again in clean hexane or toluene, with gloves worn throughout. Do not immerse the transmitter module and do not let the sensor touch hard surfaces. Cleaning does not replace scheduled recalibration. When in doubt, replace the HygroPro RTE.

Documents and quotation

The Panametrics HygroPro datasheet is available on request and on this page. Send an RFQ with the item HygroPro RTE, the transmitter model or serial number, the pressure range and the quantity. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Datasheets & Documents
  • PDF Datasheet Panametrics HygroPro RTE Replacement Transducer Element Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.

Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.

Panametrics company profile

Founded 1960, Massachusetts, USA
Main sites Billerica, Massachusetts, and Shannon, Ireland (since 1973)
Ownership Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes
Key technology Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing
Product families TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters

Milestones

  • 1960: Panametrics is founded.
  • 1973: The Shannon, Ireland, site is established.
  • 2002: GE acquires Panametrics.
  • 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.

Panametrics product families on this page

The listed items follow the manufacturer's own grouping:

  • Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
  • Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
  • Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas

Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.

Where Panametrics flowmeters and moisture analyzers are used

Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.

Panametrics products we list

Family Examples
Flowmeters AT600 AquaTrans Clamp-On Ultrasonic Wate…, DigitalFlow GM868 General-Purpose Gas Ul…, GF868 DigitalFlow Flare Gas Ultrasonic F…, PT900 TransPort Portable Ultrasonic Flow…, XGM868i DigitalFlow Gas Ultrasonic Flow…, XMT1000 Liquid Flow Ultrasonic Transmitter
Gas Analyzer Systems Aurora TDLAS Moisture Analyzer for Natur…, HygroPro II Aluminum Oxide Moisture Tran…, moisture.IQ Multichannel Trace Moisture…

Ordering Panametrics equipment: what we need

A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.

Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.

FAQ

Questions about the Panametrics HygroPro RTE Replacement Transducer

Answers from our engineering team on installation, compatibility and integration.

01What is the Panametrics HygroPro RTE?
It is the replaceable transducer element of the HygroPro moisture transmitter, containing the aluminum oxide moisture sensor, temperature thermistor, pressure transducer and electronics.
02How often should the HygroPro RTE be recalibrated or replaced?
Panametrics recommends recalibrating the aluminum oxide sensor every six to twelve months, either by returning the element or by installing a new one.
03Do I need to enter calibration data after replacing the HygroPro RTE?
No. The calibration data are stored in non-volatile EEPROM in the element and the HygroPro electronics read and store them automatically.
04What dew point range does the HygroPro cover?
The datasheet gives a standard calibration range of +10 to -80 C dew or frost point, with data from +20 to -110 C, and accuracy of plus or minus 2 C above -100 C.
05How can I request the HygroPro RTE in Oman?
Send an RFQ with the item name, transmitter model or serial number, pressure range and quantity. Seven Star LLC is an independent supplier and replies with availability for Oman and the GCC.