- Vibration Monitoring
- Industrial Communications
- PLC & I/O Cards
- AC Drives
- Automation Accessories
- Controllers & Data Acquisition
- Industrial Computers
- Encoders
- Safety Switches & Guard Locking
- CCTV & Security
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Servo Drives
- Robotics
- Machine Vision
Brand: Soler & Palau
Soler & Palau TD-1000/200 SILENT 3V Ultra-Quiet Duct Fan
Description
Ultra-quiet extract and supply for occupied rooms, 200 mm duct
The Soler & Palau TD-1000/200 SILENT 3V is the quiet counterpart of an ordinary duct fan: a mixed flow fan in plastic with sound-absorbent insulation, rated 1040 m3/h at high speed and only 29 dB(A) at 3 m. The S&P catalogue positions the series for places where people work and low sound level is required, and it notes that TD-350, TD-500, TD-800 and TD-1000 models carry a Noise Abatement Society certificate of approval.
That combination makes the model a natural choice for consulting rooms, meeting rooms, hotel corridors, serviced apartments and prayer or majlis spaces fitted with ceiling ductwork, where a standard duct fan of similar airflow would be noticeably louder. It connects to 200 mm circular duct and is wired as a single-phase 230 V fan.
How the SILENT design works, per the datasheet
- A specially designed internal skin directs sound waves at the right angle to be captured by the sound-absorbent material.
- Rubber gaskets at inlet and outlet absorb vibration, and the body can be dismantled for cleaning.
- Connection box can be rotated 360 degrees to ease cabling.
- Motor: speed-controllable 230 V, 50 Hz, class B, ball bearings, safety thermal overload protection, IP44; three speeds on this code.
- Quiet Mark approval symbol shown for TD-350, TD-500, TD-800 and TD-1000 in the catalogue.
Technical specification
| Parameter | Value |
|---|---|
| Model / order code | TD-1000/200 SILENT 3V |
| Duct diameter | 200 mm |
| Supply | Single phase 230 V, 50 Hz |
| Speeds, rpm (H / M / L) | 2450 / 2210 / 1920 |
| Max absorbed power (H / M / L) | 130 / 127 / 122 W |
| Max absorbed current (H / M / L) | 0.55 / 0.55 / 0.53 A |
| Max airflow (H / M / L) | 1040 / 910 / 790 m3/h |
| Sound pressure at 3 m (H / M / L) | 29 / 27 / 24 dB(A) |
| Air temperature | -20 to +60 degC |
| Weight | 8.7 kg |
| Wiring diagram no. | 9, 10 |
| 3-speed switch | COM-3 or INTER 4P |
| Speed controllers | RMB-1,5 and REB-1 |
| Dimension letter | mm, TD-800 and TD-1000 SILENT |
|---|---|
| A | 568 |
| B (diameter) | 198 |
| C | 327 |
| D (diameter) | 264 |
| E | 145 |
| F | 340 |
| G | 129 |
| H | 164 |
Picking the TD-1000/200 over TD-800/200
Both share a 200 mm spigot, the same 8.7 kg weight and the same dimension table. The TD-1000/200 gives 1040 m3/h at 29 dB(A) against 910 m3/h at 28 dB(A) for the TD-800/200 SILENT 3V on the high-speed points, so choose the 1000 when you need the extra roughly 14 percent airflow (derived) for a small noise increase.
The T version, TD-1000/200 SILENT T 3V, adds a run-on timer adjustable from 1 to 30 minutes; the datasheet says timer operation applies only on high speed, and these models are not suitable for speed control. Specify the plain code if you want a 3-speed switch.
Installation
The datasheet shows a five-step service sequence that doubles as installation guidance: loosen and open the clamps on both sides, remove the fan body, remove the terminal box lid, connect the electrical supply, then remount the fan body by tightening the clamps. The support bracket allows wall or ceiling installation and has twin-material supports for the motor section that absorb vibration.
Check the data plate voltage and frequency against the supply first, and use rigid ducting at both ends if you want to compare site sound levels with the catalogue figures, which are measured at 3 m in free air.
What the control and accessory codes actually do
The catalogue describes the controls in plain terms. COM-3 and INTER 4P are three-speed switches; REGUL 2 is a two-speed switch; REB is a single-phase electronic speed controller and RMB an auto-transformer type. For demand-controlled ventilation the datasheet offers an ECOWATT control that adapts fan speed to sensor readings, and a VAPZ regulator that takes a presence contact or a 0-10 V or 4-20 mA input from a CO2 probe or relative humidity sensor.
On the mechanical side, the MCA non-return flap goes at the fan discharge to prevent heat leakage when the fan is off, the MAR adapter connects to rectangular ducting, the MRJ grille keeps foreign objects out of the impeller, the MPC detector measures pressure at the inlet of TD units with an airflow straightener, and the MBR flange couples SILENT fans in series.
- Quote the full code TD-1000/200 SILENT 3V (3-speed, no timer).
- State the duct diameter, 200 mm, and whether a rectangular adapter is needed.
- Say whether a switch, electronic controller or sensor-driven control is required.
- Confirm 230 V, 50 Hz single-phase supply.
Accessories printed for this size
| Accessory type | Code |
|---|---|
| Non-return flap | MCA-800-1000 S |
| Rectangular duct adapter | MAR-800-1000 S (315 x 200 mm duct) |
| Inlet or outlet grille | MRJ-800-1000 S |
| Flow detector | MPC-800-1000 S |
| Series flange | MBR-800-1000 S (200 mm duct) |
| Controllers | REGUL 2, REB, ECOWATT, AC/4A VAPZ |
| Sensors | SCO2-A (CO2 and temperature), CPTA-S/CPTA-E presence detectors |
Browse other ventilation and HVAC equipment if the duty calls for a larger casing.
Installation and selection notes
Quiet operation depends on the whole installation, not only the fan. Hang it on resilient mounts, keep duct velocities moderate, avoid sharp bends immediately before or after the fan and add flexible connectors. Compare the printed sound level with the room limit in the specification, and remember that sound at 3 m in free field differs from the level inside an actual room.
Information needed for a quotation
Send the full model code, the quantity, the supply voltage and phase, the delivery location in Oman or the GCC and any accessories such as controllers, silencers, dampers or flexible connectors, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification before a purchase is confirmed. Airflow, pressure, sound and motor values are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Frequently asked questions
How loud is the TD-1000/200 SILENT 3V? 29, 27 and 24 dB(A) at 3 m on high, medium and low speed, measured in free air with rigid ducts at inlet and outlet.
What duct diameter does it fit? A 200 mm circular duct.
Is there an approval mark? The catalogue shows a Noise Abatement Society certificate of approval for TD-350, TD-500, TD-800 and TD-1000.
Can the speed be controlled? Yes, via a COM-3 or INTER 4P switch, or REB-1 and RMB-1,5 controllers. Timer versions marked T are not for speed control.
Is Seven Star LLC the manufacturer? No. Seven Star LLC is an independent supplier in Muscat; confirm the exact model, voltage and options before ordering.
Datasheets & Documents
- Datasheet Soler & Palau TD-SILENT series catalogue pages (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Soler & Palau is a Spanish ventilation manufacturer founded in 1951 and based near Barcelona. The S&P brand is known for duct fans, roof fans, cabinet fans and centrifugal fans used in building and industrial ventilation.
Seven Star LLC is an independent supplier in Muscat. We list Soler & Palau fans against exact model codes for HVAC contractors and facility teams in Oman and the GCC.
Soler & Palau product series
In-line duct fans include the TD-MIXVENT mixed flow models such as the TD-500/150, TD-2000/315N and three-phase TD-4000/355, and the TD-SILENT acoustic versions TD-1000/200 and TD-2000/315. The TH-1300 is a roof-mounted mixed flow fan.
Cabinet and centrifugal fans include the CAB-355 acoustic cabinet fan, the CVHT-12/12 smoke extract cabinet fan rated F400-120, the CVTT-15/15 belt-driven cabinet fan for 12,800 m3/h and the CBM-12/12 centrifugal fan for 8,290 m3/h. Each series datasheet gives airflow, pressure curves, sound pressure, motor data and dimensions.
Where Soler & Palau fans are used
Kitchen, toilet and car park extract, fresh air supply, smoke extraction, plant room ventilation and general industrial ventilation in commercial and industrial buildings.
Ordering Soler & Palau fans: what we need
Send the exact model code, or the required airflow and static pressure, the supply voltage and phase, the duct size or mounting arrangement and, for smoke extract fans, the temperature and time rating required.
Browse Soler & Palau products by category: Industrial Fans & Blowers.
Related products
Frequently Asked Questions
29, 27 and 24 dB(A) at 3 m on high, medium and low speed, measured in free air with rigid ducts at inlet and outlet.
A 200 mm circular duct.
The catalogue shows a Noise Abatement Society certificate of approval for TD-350, TD-500, TD-800 and TD-1000.
Yes, via a COM-3 or INTER 4P switch, or REB-1 and RMB-1,5 controllers. Timer versions marked T are not for speed control.
No. Seven Star LLC is an independent supplier in Muscat; confirm the exact model, voltage and options before ordering.