Brand: CEMP
CEMP AAB30/AAC30 Aluminium Frame 56 Ex db Motors
Description
Small aluminium frame 56 Ex db motors for fans and small pumps
The CEMP AAB30/AAC30 aluminium frame 56 motors are small three-phase, 60 W to 120 W flameproof motors used mainly for fixed and portable fan applications, and also for small pumps and other duties that call for ATEX and IECEx certification. Several mounting types are possible in the same enclosure, and the terminal box sits at the non-drive end, giving a slim shape for tight spaces. The brochure explains that aluminium offers high resistance to corrosion and atmospheric attack, except in some harsh environments such as sulfuric acid, and is about one third the weight of cast iron.
Technical specifications
| Parameter | Specification |
|---|---|
| Series | AAB30 / AAC30, aluminium frame 56 |
| Standards | IEC/EN 60079-0, -1, -31; IEC 60034-1, -2, -5, -6, -7, -8, -9, -12, -14, -30; IEC 60072 |
| Protection | Ex db, Ex tb |
| ATEX category | II 2G, II 2D, II 2GD |
| Groups | Gas IIB, IIC; dust IIIB, IIIC |
| Temperature classes | T3, T4, T5, T6 |
| Dust surface temperature | T150 C, T135 C, T125 C, T100 C, T85 C |
| Ambient | Enclosure for -60 / +80 C; maximum +60 C for IIC and +80 C for IIB |
| Protection degree | IP55, IP65 |
| Frame size | 56 (IEC) |
| Mounting | B3, B14, B34, B5, B35, pad mounted |
| Power | 0.06 to 0.12 kW, three phase |
| Voltage | 400 V, 50 Hz; multi-voltage 380-400-415 V / 50 Hz and 460 V / 60 Hz |
| Poles | 2, 4, 6 |
| Cooling | Not ventilated IC410; terminal box on the back side |
| Other | PTC for inverter use; stainless steel nameplate; multi-voltage nameplate |
| Document | CEMP Aluminum Frame 56 brochure, Cod 50164852 Rev 00, May 2026 |
Fit and application notes
At 60 to 120 W these motors serve special applications that need very low power or a small footprint. Because they are not ventilated (IC410), duty and ambient temperature must be checked against the temperature class. The dust marking and surface temperature depend on the Ex tb construction, and the gas group IIB or IIC limits the maximum ambient (60 C for IIC, 80 C for IIB). Mounting flexibility lets one motor type serve foot, flange or pad mounting. The brochure also highlights a stainless steel nameplate, a multi-voltage nameplate and PTC protection for inverter use, with certifications available on request. For larger power or other frame sizes, the E3A/E4A flameproof series in the same brochure starts at frame 80, so the frame and kW should be fixed first.
Ordering information
The brochure is a series summary, not an ordering code table, so the exact designation, mounting, voltage and certificate version must be confirmed with the manufacturer. State the rated power, poles, voltage, frequency, mounting, ambient, group and temperature class, and note that certifications are available on request.
Typical applications in hazardous areas
These frame 56 flameproof motors are intended for low-power drives inside classified areas. The brochure names fixed and portable fan applications and small pumps, and in practice this covers ventilation of analyser shelters and small enclosures, portable ventilation used during maintenance in hazardous zones, small transfer and dosing pumps, and other compact auxiliary equipment in refineries, gas plants, chemical facilities, fuel depots and dusty process areas covered by the dust markings in the table.
The slim shape with the terminal box at the non-drive end helps where a motor must fit inside equipment or close to other components, which is common on skid-mounted packages and portable units.
Selection for the hazardous area
Start from the area classification. Confirm whether the location is gas, dust or both, then select the group and temperature class required by the area classification drawing. Gas group IIC covers the most demanding gases but carries the lower maximum ambient stated in the table, while IIB allows a higher ambient. For dust areas, compare the maximum surface temperature of the motor with the ignition temperature of the dust present. Because the motor is not ventilated, check the duty cycle and the ambient together, especially where the motor runs continuously.
Where the motor will be fed from an inverter, the PTC option listed in the brochure should be part of the order discussion, and the inverter and motor combination should be reviewed against the certificate conditions.
Installation practice
Installation in hazardous areas must follow the certificate conditions and the applicable installation rules for the site. Make the electrical connection in line with the certificate and the protection concept, keep flameproof joints clean and undamaged, and do not modify the enclosure. Check that the nameplate marking matches the area requirements before installation. Choose the mounting type that matches the driven equipment so that the motor is supported correctly and alignment is maintained.
After installation, record the motor marking, area classification and inspection results in the hazardous-area register for the site. Periodic inspection should check the condition of the enclosure, the terminal box cover and the mounting, and any repair to a flameproof motor should be carried out in line with the certificate and the applicable repair rules rather than by improvised methods on site. Keeping the brochure and certificate details with the motor records helps maintenance staff confirm that a replacement motor carries the same marking, group, temperature class and mounting as the original.
Site conditions in Oman and the GCC
Oil, gas and petrochemical facilities in Oman often combine hazardous-area classification with high ambient temperatures, so the ambient limits in the table must be compared with the hottest expected conditions at the motor location, including direct sun. The brochure notes the good corrosion resistance of aluminium, but it also names harsh environments where this does not hold, so the actual chemical exposure at the site should be checked. Dust and sand favour the higher protection degree in the table for outdoor and desert installations.
Documents and quotation
Provide the fan or pump load, power, poles, voltage, mounting form, zone and temperature class. The brochure states that the values may change without prior notice and are reference values.
The manufacturer document is attached to this page and listed below. Seven Star LLC is an independent supplier in Muscat and can quote against the model code, quantity and delivery location. Browse more instruments in Electric Motors, or see the CEMP brand page.
Datasheets & Documents
- Brochure CEMP aluminium frame 56 series AAB30/AAC30 brochure (May 2026) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
CEMP is an Italian maker of explosion-proof electric motors, founded in 1954 and one of the first Italian companies to make flameproof motors. Based in Senago, near Milan, it makes Ex db, Ex db eb and Ex ec motors from 0.12 to 375 kW, as well as brake motors and safe-area motors. CEMP is now part of the WEG Group.
Seven Star LLC is an independent supplier in Muscat. We list CEMP motors for oil and gas and process plants in Oman and the GCC.
CEMP company profile
| Founded | 1954, Italy |
|---|---|
| Headquarters | Senago, near Milan |
| Group | WEG |
| Range | 0.12 to 375 kW |
| Product families | E3A and E4A flameproof motors, E3H/D and E4H/D brake motors, TerraMAX TC motors, Ex ec increased-safety motors |
CEMP product series
Flameproof motors include the E3A/E4A Series Ex db motors in IE3 and IE4, the E3H/D and E4H/D flameproof brake motors and the AAB30/AAC30 aluminium frame 56 Ex db motors.
The TerraMAX TC Series (TCN, TCT, TCE) are motors in IE3 and IE4 efficiency.
Flameproof Ex db motors contain any internal explosion so it cannot ignite the surrounding gas. Motors are selected by gas group, temperature class, power, speed and mounting, and IE3 and IE4 versions reduce energy use.
Brake motors hold loads on hoists and conveyors in hazardous areas.
Where CEMP motors are used
Pumps, fans, compressors and hoists in refineries, gas plants, chemical plants and other hazardous areas.
CEMP products we list
| Family | Examples |
|---|---|
| Electric Motors | E3A/E4A Series Flameproof Motors Ex db I…, E3H/D and E4H/D Flameproof Brake Motors, TerraMAX TC Series Motors TCN TCT TCE IE… |
Ordering CEMP motors: what we need
Send the series, power, poles, voltage and frequency, frame and mounting, and the Ex marking and temperature class required.
Facts checked against CEMP's own site and company profiles, October 2026.
Browse CEMP products by category: Electric Motors.
FAQ
Questions about the CEMP AAB30/AAC30 Aluminium Frame 56 Ex db Motors
Answers from our engineering team on installation, compatibility and integration.
01What power does the CEMP AAB30/AAC30 cover?
0.06 to 0.12 kW, three phase, 2, 4 and 6 poles.
02What protection types are listed?
Ex db and Ex tb, ATEX category II 2G, II 2D and II 2GD.
03How are the motors mounted?
B3, B14, B34, B5, B35 and pad mounted, in the same enclosure.
04How are they cooled?
Not ventilated, IC410, with the terminal box on the back side.
05What are the typical uses?
Fixed and portable fans and small pumps where ATEX and IECEx certification is needed.