Brand:

Mobrey MLT100 SMART HART Displacer Level Transmitter

Description

Displacer level transmitter with HART output for vessels and chambers

The Mobrey MLT100 is a two-wire, loop-powered displacer level transmitter that couples the buoyancy principle with LVDT electronics. A displacer made to length for each order hangs from the head on a spring arrangement designed to reduce friction. As the liquid level rises or falls the displacer moves a core inside the stainless steel pressure tube, and a linear variable differential transformer around the tube produces a signal proportional to the core position. The transmitter outputs 4-20 mA with HART superimposed and can measure level, content or interface.

The datasheet describes a small mounting envelope, a choice of direct vessel mounting or external mounting in a chamber, integral or remote electronics, and wetted parts in a wide range of materials. Flameproof construction is available for Zone 1 areas.

Technical specifications

Parameter Specification
Measuring principle Displacer on spring with LVDT; level, content or interface
Output signal 4-20 mA with HART (version 5)
Power supply 12 to 40 Vdc, loop powered
Power consumption 21 mA / 40 Vdc / 840 mW max.
Accuracy Below 1% of span
Repeatability / linearity +/- 0.2% of span each
Resolution +/- 0.1% of span
Hysteresis +/- 0.3% of span
Specific gravity range Standard 0.5 to 1.5; interface 0.1 difference
Measuring range limits 300 to 3000 mm, specified with the order
Operating pressure -1 to 120 bar (1740 psi)
Process temperature Minimum -60 C; up to 277 C condensing and 320 C non-condensing with integral electronics; up to 320 C condensing with remote electronics
Ambient temperature -40 C to +80 C
Enclosure protection IP66 / IP67, weatherproof and flameproof versions
Wetted parts 316 stainless steel; spring in NIMONIC; Alloy C276 or Alloy 625 (NACE MR-01-75) optional
Pressure tube options A: standard, up to 224 C condensing; B: high temperature, 224 to 277 C condensing or 320 C non-condensing
Approvals as printed Sira 03ATEX1190X, II 1/2 G Ex db IIC T6 to T1 Ga/Gb (-40 C to +75 C); EMC Directive 2014/30/EU; PED 2014/68/EU Sound Engineering Practice
Datasheet revision TDS-MLT100-D, June 2026

Model code and construction options

The model code is built from eleven tables. The base model is LT. Flange material is carbon steel (C), stainless steel (S) or no flange with a 1-inch NPT connection (N). Flange sizes cover 3 and 4 inch ASME B16.5 Class 150, 300 and 600 raised face, and DN80 and DN100 in PN16, PN25 and PN40, with a further list of 1 to 2 inch flanges for chamber connections. The enclosure is selected from ZF (IP66 safe area, cast iron), TF (Ex d flameproof cast iron), TR (Ex d with remote electronics in an IP66 aluminium enclosure for the non-hazardous area) and TG (Ex d, AISI 316 stainless steel).

A display option adds a two-line LCD in a cast aluminium Ex d enclosure. The spring and displacer codes are assigned by Delta Mobrey from the process conditions, and chamber style codes cover side-bottom and side-side arrangements with vent and drain options. A typical model number printed in the datasheet is LT C 61 TS A D * * B 11 00.

Calibration, materials and application notes

Local adjustment of the 4 mA and 20 mA points and damping can be made with the Mobrey Magnetic Scroller and the Caliplug, which also carries a heartbeat LED that flashes every 3 seconds. Remote ranging uses a HART Field Communicator. Pressure-retaining parts are hydrostatically tested to at least 1.5 times working pressure, welding is qualified to ASME IX, BS EN 287 and EN ISO 15614-1, and NDT such as radiography and dye penetrant is available when specified at order. The datasheet lists process plants, water treatment, power plants and oil, gas and petrochemical service as typical uses.

Documents and quotation

Before ordering, confirm the vessel connection, flange rating, fluid density and interface density, displacer length, process temperature and pressure, enclosure and hazardous-area requirement. The displacer and spring are unique to each instrument, so they must be specified from process data.

The manufacturer document is attached to this page and listed below. Seven Star LLC is an independent supplier in Muscat and can quote against the model code, quantity and delivery location. Browse more instruments in Level Instrumentation, or see the Mobrey brand page.

Datasheets & Documents
  • PDF Datasheet Mobrey MLT100 technical datasheet TDS-MLT100-D (June 2026) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Mobrey is a process instrumentation brand of Delta Mobrey Ltd, headquartered in Camberley, Surrey, United Kingdom. Its range centres on level measurement, with magnetic float and displacer level switches, displacer and hydrostatic level transmitters, ultrasonic transmitters and solids level switches, together with vane flow switches for air ducts. Seven Star LLC supplies these instruments in Oman on inquiry.

Level and flow instruments listed

The models on this page include the MLT100 HART displacer level transmitter, magnetic horizontal and vertical float level switch chambers, the 9710 submersible hydrostatic transmitter, DMSP ultrasonic transmitters, PLS paddle and DMS vibrating fork switches for solids, and the 131 vane operated flow switch. Datasheets are issued under the Delta Mobrey name.

Ordering level and flow instruments

Send the model code from the nameplate or datasheet, process connection, pressure and temperature, medium and hazardous-area requirement. The datasheets describe how the full model code is built, so the exact configuration can be confirmed before an offer is issued.

Frequently Asked Questions

What measurement principle does the Mobrey MLT100 use?
A displacer on a spring moves a core inside a pressure tube, and an LVDT converts the core position into a 4-20 mA HART signal for level, content or interface.
What process temperature range is stated?
The datasheet gives a minimum of -60 C and a maximum of 277 C condensing or 320 C non-condensing with integral electronics, and 320 C condensing with remote electronics.
Can it be mounted outside the vessel?
Yes. It can be mounted directly in a vessel or in an external chamber, with side-bottom or side-side connection styles.
Is a hazardous-area version available?
Flameproof Ex d enclosures are offered, with Sira 03ATEX1190X marking II 1/2 G Ex db IIC T6 to T1 Ga/Gb as printed in the datasheet.
What must be specified for the displacer?
Operating conditions and measuring range from 300 to 3000 mm, because Delta Mobrey selects the spring and displacer for each order.