Brand: Fluke
Fluke 117 Electrician’s True-rms Multimeter with VoltAlert
Description
A compact true-rms multimeter built for electricians
The Fluke 117 Electrician’s Multimeter is a compact CAT III 600 V true-rms digital multimeter with integrated non-contact voltage detection (VoltAlert), automatic AC/DC voltage selection (AutoVolt) and a selectable low-impedance mode (Auto-V LoZ) that prevents false readings from ghost voltage. A quick turn of the dial gives voltage, resistance, continuity, frequency, capacitance and Min/Max/Average, and the backlit display suits dark worksites. Fluke positions it for commercial buildings, hospitals and schools; it ships with 4 mm silicone test leads, a holster and a manual.
Technical specifications
| Parameter | Specification |
|---|---|
| Display | 6,000 counts, updates 4 per second; 33-segment bar graph updating 32 per second; backlight |
| DC volts | 600.0 mV / 6.000 V / 60.00 V / 600.0 V; accuracy 0.5% + 2 (mV and V) |
| AC volts true-rms | 6.000 V / 60.00 V / 600.0 V; 1.0% + 3 (45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz); AC mV 600.0 mV same accuracy |
| Auto-V LoZ | 600.0 V; 2.0% + 3 (45 to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz); input about 3 kohm |
| AC / DC current | 6.000 A and 10.00 A (20 A overload for 30 s); AC true-rms 1.5% + 3 (45 to 500 Hz); DC 1.0% + 3; 10 A input burden 37 mV/A |
| Resistance | 600.0 ohm to 40.00 Mohm; 0.9% + 1 or 2 up to 6 Mohm, 5.0% + 2 at 40 Mohm |
| Capacitance | 1000 nF, 10.00 uF, 100.0 uF, 9999 uF; 1.9% + 2 (100 to 1000 uF), above 1000 uF 5% + 20; LoZ capacitance 10% + 2 typical |
| Frequency | Up to 50 kHz on volts input and amps input (0.1% + 2) |
| Diode test and continuity | Diode 2.000 V, 0.9% + 2; continuity beeper on below 20 ohm, off above 250 ohm |
| Input impedance | AC volts above 5 Mohm; DC volts above 10 Mohm |
| Safety | IEC 61010-1 Pollution Degree 2; IEC 61010-2-033 CAT III 600 V, 10 A; maximum 600 V rms to earth ground |
| Protection | Fuse for A input 11 A, 1000 V, IR 17 kA (Fluke PN 803293); IP42 |
| Power | 9 V alkaline (IEC 6LR61); about 400 hours without backlight |
| Operating conditions | -10 to +50 C; storage -40 to +60 C; humidity 0 to 90% to 35 C; altitude 2,000 m |
| Certifications and warranty | CE, CSA, RCM; 3-year limited warranty per the multimeter safety sheet |
All accuracies are specified for one year after calibration at 18 to 28 C and 0 to 90% RH. Because inputs below 1% of range are not specified, true-rms meters can show small non-zero readings with open leads, which is normal.
Choosing between the 114, 115, 116 and 117
The 114, 115, 116 and 117 share one platform. According to the specification sheet, Auto-V LoZ is on the 114, 116 and 117; AC and DC current inputs on the 115 and 117; capacitance and diode test on the 115, 116 and 117; and the K-type temperature input only on the 116. Fluke describes the 115 as the field-service model and the 117 as the electrician model, which adds non-contact voltage detection and the low-impedance mode. Models in the family carry their own kits, such as the 117 with insulated hand tools, with a 323 clamp meter or with a 240 V proving unit.
For work on live installations always use test leads and accessories rated for the measurement category, and measure a known source before and after a safety-critical test, as the safety sheet instructs. Confirm the kit contents and any calibration-certificate requirement before ordering.
How the Fluke 117 works
A digital multimeter measures voltage, current and resistance with one instrument, and a true-rms meter gives the correct value of AC signals that are not pure sine waves, such as the current of electronic loads. The Fluke 117 has a 6,000 count display with a 33-segment bar graph and a backlight. The dial selects the function, and the meter gives AC and DC voltage, current to 10 A, resistance to 40 Mohm, capacitance, frequency, diode test and continuity, with Min, Max and Average recording.
Where the Fluke 117 is used
- Electrical maintenance in commercial buildings.
- Fault finding in lighting and power circuits.
- Checks in hospitals, schools and offices.
- Control panel and motor circuit checks.
- Quick safe voltage checks before work starts.
Selection checklist for the Fluke 117
- Safety rating of CAT III 600 V.
- True-rms AC voltage with 1.0 percent + 3 accuracy at 45 to 500 Hz.
- DC voltage accuracy of 0.5 percent + 2.
- AutoVolt automatic selection of AC or DC.
- Auto-V LoZ low-impedance mode of about 3 kohm.
- VoltAlert non-contact voltage detection.
- Current ranges of 6.000 A and 10.00 A.
- Resistance from 600.0 ohm to 40.00 Mohm.
- Capacitance up to 9999 uF.
- Operating range of -10 to +50 degrees C.
Installation, commissioning and maintenance notes
Check the test leads and the meter for damage before every use, and select the right function and input terminal before touching the circuit. Use the meter only within its CAT III 600 V rating, and keep your hands behind the finger guards of the probes. The current input is protected by an 11 A fuse rated for 1000 V, so replace it only with the same type. Remove the battery if the meter will not be used for a long time, and clean the case with a damp cloth.
Requesting a quotation for the Fluke 117
Send the quantity and any kit or accessory you need with the meter. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
VoltAlert and ghost voltage
VoltAlert detects AC voltage without contact, so you can see if a conductor is live before you probe it. The low-impedance mode loads the circuit lightly, so false readings from induced ghost voltage drop to zero, while a real voltage is still shown.
Power and battery
The meter runs on one 9 V alkaline battery for about 400 hours without the backlight, and it has an IP42 case rating.
Supplied with the meter
The set includes 4 mm silicone test leads, a holster and a manual, so the meter is ready for work when it is unpacked.
Fluke 117 test records
Record the circuit, the reading and the date when the values are used for maintenance reports.
Documents and quotation
The attached file is the two-page Fluke detailed-specifications sheet for the 114, 115, 116 and 117. See also the Fluke 87V for industrial work, the Fluke 1587 FC and the wider portable test and measurement range. Send quantity, kit and region for a quotation.
Datasheets & Documents
- Datasheet Fluke 114, 115, 116, 117 detailed specifications (2 pp, 08/2020) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Ask an instrument technician which calibrator is in the toolbox and the answer is often a Fluke. Founded in 1948 and based in Everett, Washington, the company makes handheld test tools, and its Fluke Calibration line supplies laboratory standards. Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Browse Fluke products by category: Portable Test & Measurement.
Related products
Frequently Asked Questions
CAT III 600 V, 10 A per IEC 61010-2-033, with 600 V rms maximum to earth ground.
It selects a low-impedance AC voltage mode (about 3 kohm) that prevents false readings from ghost voltage.
Yes, AC and DC current on 6 A and 10 A ranges, with 20 A overload for 30 seconds.
A 9 V alkaline battery, with typical life of 400 hours without backlight.
Yes, integrated VoltAlert technology gives go/no-go detection of live voltage.