Brand:

Bürkert 137534 Type 6013 Stainless G1/4 Solenoid Valve AC

Description

Overview

Bürkert 137534 is the stainless steel version of the G¼ Type 6013 plunger valve for 24 V 50 Hz supply. It has a 2.0 mm orifice, a water Kv value of 0.12 m3/h, an FKM seal and a rated pressure range of 0 to 25 bar, which is twice the figure of the DC version. It is direct-acting and normally closed. Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical data of Bürkert 137534

Parameter Value
Article 137534, stainless steel body, G 1/4
Orifice and Kv 2.0 mm, 0.12 m3/h water
Voltage 24 V 50 Hz
Pressure range 0 to 25 bar
Family Bürkert Type 6013, direct-acting 2/2-way plunger valve
Circuit function A, normally closed
Seal FKM
Coil Polyamide class B or epoxy class H, tolerance plus or minus 10 percent
Medium Technical vacuum, neutral gases and liquids
Medium temperature with FKM minus 10 to plus 100 degrees C (PA coil), plus 120 degrees C (epoxy coil)
Viscosity max. 21 mm2/s
Ambient temperature max. plus 55 degrees C
Electrical connection Form A, DIN EN 175301-803, cable plug Type 2518 or 2509 ordered separately
Protection IP65 with cable plug

Stainless and AC: what Bürkert 137534 combines

The body is stainless steel 1.4305 or 1.4303, which resists corrosion in coastal and washdown conditions, and the AC coil develops a higher pull-in force that justifies the 25 bar rating. The cost is higher inrush current and some coil hum. Compared with the brass AC article 137538 the hydraulics are identical, and compared with the stainless DC article 137533 the pressure range doubles.

Fluid compatibility checklist

FKM suits oils, many fuels and mineral media but dislikes steam, amines and some polar solvents. PTFE with graphite handles steam, solvents and temperatures up to 180 degrees C but needs a higher closing force for leak tightness. EPDM is available on request for water and hot water duties. The analytical variant, with brass or stainless steel only, is meant for neutral media that do not attack the body and seals. Consult the Bürkert resistApp referenced in the data sheet for chemical resistance of individual combinations.

Troubleshooting a valve that will not open or close

If the valve does not open, measure the coil voltage at the plug under load, check coil resistance against the type plate, and confirm that line pressure is within the pressure range of the article. A DC coil on an AC-rated pressure may fail to lift the plunger. If it does not close, look for particles under the seat, an incorrectly fitted plug or a supply that stays energised through a leaking relay contact. Replace the valve if it leaks after cleaning.

Why the AC coil rates 25 bar in Bürkert 137534

The AC solenoid produces a strong pull when the plunger is far from the core, and a hold current once it is closed in. Together with the 2.0 mm seat, this gives a pressure capability of 25 bar, against 12 bar for the DC coil of the same row. For a user, this means that a plant with a 24 V AC control transformer can switch higher pressure lines than one with a DC rail. The trade-offs are higher inrush current, a faint hum from the coil and the need to keep the core free of dirt, because a jammed AC coil overheats.

For critical duties on AC, use a thermal fuse or a monitored output that detects failure to close.

Stainless steel body in Bürkert 137534

The stainless body gives corrosion resistance in washdown, coastal and chemical environments. It is machined from stainless steel 1.4305 or 1.4303, suited to water, air, many oils and neutral chemicals. The FKM seal remains the weaker link for hot water and amines, so check the medium. The stainless versions can be paired with cable plug Type 2509 where NEMA 4X style protection is wanted.

Applications that suit Bürkert 137534

The combination of stainless steel and 25 bar capability makes this valve valuable in compressed air at 16 to 25 bar, hydraulic pilot lines, high-pressure washdown systems, and small steam or hot water lines within the limits of FKM. At 2.0 mm orifice the flow is small, so it is a pilot or sampling valve. In petrochemical and power plants, valves like this often serve as drain and vent valves on instrument lines.

Connect to 24 V AC from a machine control transformer, and protect with a small fuse.

Compatibility and checks before ordering Bürkert 137534

Confirm the medium and temperature with the seal limits, confirm that the supply is 24 V at 50 Hz and not 60 Hz, and verify the line pressure against the 25 bar rating of the AC column. Remember that a plug must be ordered separately, and that for outdoor washdown, plug Type 2509 is the one the data sheet associates with NEMA 4X on stainless variants. State these items in the RFQ to get the right article.

Ordering notes for Bürkert 137534

Quote the complete article number. The brass AC twin has number 137538, the 230 V version is 137536 in stainless, and the DC version is 137533. If your system voltage is 24 V DC, do not use this article, because the AC coil will not operate correctly on direct current.

Delivery and documentation for Bürkert 137534

The valve is supplied with its AC coil and FKM seal and needs a separate cable plug. The Type 6013 data sheet attached to this page contains dimensions, power data and the ordering chart. Tell us at enquiry stage whether material certificates or declarations are needed for your project, so that these can be requested together with the valve before shipment to your site in Oman or the wider GCC.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Norgren 85750 Solenoid Actuated Shut-Off Valve | All Bürkert products.

Documents and quotation

The Type 6013 data sheet that covers Bürkert 137534 is attached with ordering charts, power data and dimensions. Please send an RFQ with part number 137534, the quantity and your delivery location in Oman or the GCC.

Other Models in the 6013 Range

Seven Star LLC supplies models from the 6013 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Bürkert 137537 Type 6013 Brass G1/4 Solenoid Valve 24V DCSolenoid ValvesView details
Bürkert 137534 Type 6013 Stainless G1/4 Solenoid Valve ACSolenoid ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Bürkert 137534 Type 6013 Stainless G1/4 Solenoid Valve AC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 137534 Type 6013 Stainless G1/4 Solenoid

Answers from our engineering team on installation, compatibility and integration.

01What body has Bürkert 137534?
It has a stainless steel body with a G 1/4 port and a 2.0 mm orifice.
02What pressure range has 137534?
The ordering chart lists 0 to 25 bar for the 24 V 50 Hz version.
03What voltage is Bürkert 137534?
This article is the 24 V 50 Hz AC version; DC and 230 V articles have other numbers.
04What is the Kv value of 137534?
The water Kv value is 0.12 m3/h with a 2.0 mm orifice and a G 1/4 port.
05Is a cable plug included with Bürkert 137534?
No, the cable plug is ordered separately according to the data sheet.