Brand: Bürkert
Bürkert 131423 Type 6519 NAMUR Solenoid Valve 110 V AC
Description
Overview
Bürkert 131423 is a Type 6519 NAMUR solenoid valve with nickel-plated brass socket bushings, a 6 millimetre orifice and a 110 V, 50 or 60 Hz AC coil. As a 5/2-way valve with pressurisation via port 1, it is the direct-mount pilot valve for double-acting rotary actuators on plants where 110 V control circuits are still standard.
Coil, voltage and what the number means
The chart pairs each of four supply voltages with its own article number. For the nickel-plated brass family the sequence is 131421 for 24 V DC, 131422 for 24 V AC, 131423 for 110 V AC and 131424 for 230 V AC. Choosing 131423 therefore tells the supplier the socket material, the orifice and the voltage in one number. The AC coil draws an inrush of about 11 VA with the 32 millimetre coil and holds with lower power, while the DC coil used on the 24 V DC valves holds with 1.7 to 2 watts.
In the 5/2-way arrangement described by the chart, supply air enters port 1. One of the working ports 2 or 4 is always under pressure, so a double-acting actuator is positively driven in both directions. Releasing the coil reverses the spool and exhausts through ports 3 and 5.
Specification list for Bürkert 131423
- Pilot-operated NAMUR flange valve for direct actuator mounting, working ports 2 and 4 on the NAMUR face
- Circuit function: 5/2-way with pressure applied via port 1; a changeover plate in the delivery allows 3/2-way use too
- Orifice 6 mm with QNn 900 litres per minute at 6 bar and 1 bar differential pressure
- Supply voltage 110 V at 50 or 60 Hz with plug form A according to DIN EN 175301-803
- Pressure range 2 to 10 bar; seals in NBR and PUR; manual override
- Medium temperature minus 10 to plus 55 degrees Celsius and ambient minus 25 to plus 55 degrees Celsius
- Switching times about 20 ms to open and 40 ms to close; weight about 320 g or 476 g depending on the coil size
- G ¼ or NPT ¼ supply sockets 1, 3 and 5, which can also be flanged
How 131423 differs from other 6519 variants
Compared with 131425, which has stainless steel sockets and a 24 V DC coil, article 131423 has nickel-plated brass sockets and runs on 110 V AC. Compared with 131424, the voltage is lower, and compared with 131422, higher. The standard-body G ¼ valves such as 132468 use an 8 mm orifice and 1300 litres per minute and serve larger actuators. Ex-approved coils exist for hazardous areas under their own numbers, and the NPT socket version of this valve is available on request rather than from stock lines.
Why 110 V AC still matters for Bürkert 131423
Many older panels in Gulf refineries, power stations and gas plants were built with 110 V AC control circuits, and replacement valves must match the existing coil voltage because changing a panel supply is costly. Supplying the right voltage from the first order avoids a coil swap in the field, and since the valve is a drop-in on the NAMUR face, the change can be made during a short outage.
Mounting and wiring
After fitting the valve and gasket on the actuator, connect the supply air to port 1 and fit silencers on the exhaust. Wire the 110 V supply to the form A cable plug that is ordered separately, and observe the protective earth. Test the manual override, then energise the coil to confirm the stroke. Note that the AC coil can buzz if the armature is not fully seated because of low air supply or contamination, so check pilot pressure first.
Hazardous areas and conversion
Many 110 V sites are also classified areas. The data sheet describes Ex mb coils with moulded cable and Ex eb mb coils with a terminal box, both approved under ATEX and IECEx, that fit the identical valve body. This means a standard valve such as article 131423 can be converted to Ex operation by exchanging the coil, but the conversion must be documented and approved as a new assembly, so ask us for the right Ex coil article rather than combining parts at site. Remember that the AC Ex coils of the series use the 24, 110 and 230 V ranges and that the permitted medium temperature depends on the temperature class.
Troubleshooting guide
- Valve does not switch: check supply pressure above 2 bar, coil voltage within tolerance and plug seating
- Actuator slow: look for restrictive tubing, a clogged silencer or low supply pressure
- Coil hums loudly: verify that the pilot pressure is adequate and that the armature is clean
- Leak at exhaust: check seals and the changeover plate position, and consider contamination in the compressed air
Always isolate air and electrical supply before disassembly and use the manual override to relieve trapped pressure in the actuator.
Care and spares
Filter the air, drain moisture, and keep exhaust silencers clean. A spare coil of the correct voltage and a gasket set are the two items most often needed. Replace rubber parts when switching times drift.
Choosing the right actuator interface
The NAMUR pattern is standardised, but actuator sizes differ greatly. A small single-acting actuator for a DN 25 ball valve needs only a little air, while a large double-acting unit on a butterfly valve may need a long stroke and a big volume of air. With a flow of 900 litres per minute at 1 bar differential pressure, the valve can fill an actuator volume of many litres in a few seconds, but it is good practice to calculate the travel time from the actuator volume and tubing, especially for emergency shutdown valves with a stated closing time.
When you plan stock for Bürkert 131423, remember that spare coils and gaskets can be ordered separately and so do not require a full valve replacement after a coil failure.
Seven Star LLC is an independent supplier serving Oman and the GCC.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert 178275 Type 6027 Stainless 2/2-Way Plunger Valve | Bürkert 221602 Type 6213 Servo-Assisted 2/2-Way Solenoid Valve | All Bürkert products.
Documents and quotation
The Type 6519 data sheet explains each circuit function and lists the voltage options behind Bürkert 131423. Send an RFQ with part number 131423, the quantity and the cable plug or silencers you would like quoted.
Other Models in the Burkert 6519 Range
Seven Star LLC supplies models from the Burkert 6519 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 131425 Type 6519 NAMUR Solenoid Valve 24 V DC | Solenoid Valves | View details |
| Bürkert 131423 Type 6519 NAMUR Solenoid Valve 110 V AC | Solenoid Valves | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 131423 Type 6519 NAMUR Solenoid Valve 110 V AC Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 131423 Type 6519 NAMUR Solenoid Valve 110 V
Answers from our engineering team on installation, compatibility and integration.
01What coil voltage does Bürkert 131423 have?
It has a 110 V AC coil for 50 or 60 Hz supplies.
02Which socket material has 131423?
Nickel-plated brass sockets, in contrast with the stainless steel sockets of article 131425.
03What is the orifice and flow of 131423?
A 6 mm orifice with a QNn flow value of 900 litres per minute at 6 bar inlet and 1 bar differential pressure.
04Can 131423 work as a 3/2-way valve?
Yes, a changeover plate delivered with the valve allows operation in either circuit function.
05Is the cable plug included with 131423?
No, the cable plug form A according to DIN EN 175301-803 is ordered as a separate item.