Brand:

Pizzato CS AR-04V024 Emergency Stop Safety Module, 3NO

Description

Overview

The most common safety relay job in any plant is also the simplest to describe: watch an emergency stop button or a guard door, and open the machine’s power contacts when the circuit opens. The Pizzato CS AR-04V024 does that job with three normally open safety contacts and one normally closed signalling contact. It belongs to the CS AR family of Pizzato safety modules, works up to SIL 3, PL e and category 4, and runs from 24 V ac/dc with screw terminals. What distinguishes the AR-04 within its family is the fast response, below 50 ms, together with a start input that can be set to automatic, manual or monitored operation by the wiring. Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical data for Pizzato CS AR-04V024

Item Catalogue value
Function Emergency stop, guard end position and magnetic sensor monitoring
Safety limits SIL 3, PL e, category 4
Inputs 1 or 2 channels, contacts or magnetic safety sensors
Start Automatic, manual or monitored, configured by wiring
Outputs 3NO safety, 1NC signalling, forcibly guided, silver alloy
Supply, code 024 24 Vac/dc, 50 to 60 Hz, plus or minus 15 percent
Power consumption Below 5 VA on ac, below 2 W on dc
Input data Up to 50 ohm per input, below 30 mA per input
Minimum start pulse Over 100 ms
Response time tA Below 50 ms
Release time tR1 Below 20 ms; below 70 ms without supply
Contact ratings AC-15 3 A at 230 V; DC-13 4 A at 24 V; Ith 6 A per branch
Total squared current 64 A2; minimum current 10 mA
Housing PA 66 V0; IP40; terminals IP20; design A
Temperature Minus 25 to plus 55 degrees Celsius
Marks IMQ CP 432 DM, UL E131787, CCC, EAC

Speed matters: what the 50 ms response means

The response time tA is the time from the closing of the input circuit to the pulling in of the output relays, and the release time tR1 is the time from opening an input to dropping the outputs. For the CS AR-04 these are below 50 ms and below 20 ms. A 20 ms release is quick enough that a typical contactor, not the relay, becomes the limiting element in the stopping chain. The AR-05 and AR-06 modules list a slower response of below 300 ms, so the AR-04 is the natural choice when the module delay should be as short as possible, for example on cycling machines where an operator re-enters often.

Differences between Pizzato CS AR-04V024 and CS AR-05 or AR-06

  • The AR-04 accepts contacts and magnetic safety sensors; the AR-05 and AR-06 add OSSD semiconductor outputs as inputs.
  • Response time is below 50 ms on the AR-04 and below 300 ms on the AR-05 and AR-06.
  • Release time is below 20 ms on the AR-04 and below 15 ms on the AR-05 and AR-06.
  • Minimum start pulse is over 100 ms here and over 250 ms on the AR-05 and AR-06.
  • The AR-04 allows automatic, manual and monitored start with a single module; the AR-05 offers manual or automatic and the AR-06 only monitored start.

Wiring the start function

With automatic start the module re-energises as soon as the input circuit closes, which suits applications where the restart is controlled by other means. With manual start a push button is connected so that the outputs pull in only after the button has been pressed and released. With monitored start the module also checks that the button was open before the inputs became valid and will not start if the contact is bridged, which protects against a stuck button. The catalogue gives the wiring diagrams for each mode and the minimum start pulse of 100 ms.

Applications in Oman and the GCC

This module appears on almost every kind of machine: lathes and milling machines in training workshops, packaging lines, conveyors at ports and warehouses, mixers and extruders. Panel builders in the region like it because the same body is available for 24 V ac/dc, 120 Vac and 230 Vac, which helps them to use one concept across projects and keep a small number of spares. When more contacts are needed, expansion modules or contactors can be added.

Single channel or two channels

The inputs accept one or two channels, and opposite potentials may be connected to the two channels. A single channel is simpler and may be acceptable where the risk assessment allows it and the wiring is protected against faults, but two channels give the module the chance to detect a short circuit or a cross connection between them and to refuse to restart. For emergency stop buttons the two-channel connection with two normally closed contacts is the usual practice and the one the category 4 limit of the module assumes. With magnetic safety sensors, connect the two sensor contacts to the two channels and check the sensor cable length against the resistance limit of 50 ohm per input.

A typical circuit

Consider a conveyor with an emergency stop at each end and a hinged guard at the drive. The two e-stop buttons and the guard switch contacts are connected in series on each channel, so that any of them opens the circuit. The module’s three safety contacts open the motor contactor, the brake supply and a second contactor on the output stage, while the signalling contact tells the PLC that the safety chain is open. A reset push button sits at the control station, wired for manual or monitored start according to the required behaviour.

Installation and testing

Mount on a DIN rail, feed the supply, keep resistance per input below 50 ohm and protect the outputs with a 4 A fuse. Wire the safety circuit with the safety contacts only. Test by pressing the emergency stop and verifying that the three outputs open at once and the signalling contact closes, then reset and verify the start mode. Repeat at each periodic test and after any change to wiring.

Related items you may also need: Pizzato FR 1007 Position Switch, Adjustable Roller | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FK 301 Position Switch with Plunger, Snap Action | All Pizzato products.

Points to confirm for the Pizzato CS AR-04V024

  • If the Pizzato CS AR-04V024 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Pizzato CS AR-04V024 request we confirm the exact code, new or surplus condition and lead time in writing.
  • Dimensions, ratings and connection data for the Pizzato CS AR-04V024 are in the datasheet attached to this page.
  • The Pizzato CS AR-04V024 belongs to our safety switches & guard locking range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
  • Plants that run the Pizzato CS AR-04V024 on critical service often hold a spare unit in the store.

Documents and quotation

The catalogue chapter for the CS AR family is attached to this page and includes technical data, code structure and wiring diagrams. For a quotation, please send an RFQ with Pizzato CS AR-04V024, the quantity, the supply voltage and the delivery destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Pizzato CS AR-04V024 Emergency Stop Safety Module, 3NO Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS AR-04V024 Emergency Stop Safety Module,

Answers from our engineering team on installation, compatibility and integration.

01How fast does the Pizzato CS AR-04V024 respond?
The catalogue lists a response time below 50 ms and a release time below 20 ms, with release without supply below 70 ms.
02Which start modes does the CS AR-04V024 support?
Automatic, manual or monitored start, selected by the way the start circuit is wired.
03What contacts does the CS AR-04V024 have?
Three forcibly guided normally open safety contacts and one normally closed auxiliary contact, rated AC-15 3 A at 230 V.
04What supply does the CS AR-04V024 use?
The 024 code uses 24 Vac/dc at 50 to 60 Hz, tolerance plus or minus 15 percent, consuming below 5 VA ac or below 2 W dc.
05Can the CS AR-04V024 take OSSD inputs?
The catalogue lists contacts and magnetic safety sensors for the AR-04, whereas OSSD semiconductor inputs are listed for the AR-05 and AR-06.