- Automation & ControlView all 3,150 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Pizzato
Pizzato CS MP204M0 Programmable Safety Module, 12 Inputs
Description
Overview
Between a tiny safety relay and a full safety PLC there is a gap, and the Gemnis modules from Pizzato fill it. The Pizzato CS MP204M0 is a programmable safety module with 12 safety inputs, 4 test outputs, 4 signalling outputs and a relay stage of three normally open safety contacts, all in a housing 45 mm wide. It is programmed through the USB port with the graphical Gemnis Studio software, and it reaches Maximum SIL 3, PL e and category 4. Compared with a semiconductor-only module it gives real relay contacts that can switch contactors and valves directly. Seven Star LLC is an independent supplier serving Oman and the GCC.
Specification for Pizzato CS MP204M0
| Item | Catalogue value |
|---|---|
| Safety inputs I | 12 |
| Test outputs T | 4 |
| Signalling outputs O | 4 |
| Safety relay circuits | 3NO |
| Programming | Gemnis Studio, USB port |
| MTTFD | 134 years |
| PFHD | 1.52E-09 per hour |
| Mission time | 20 years |
| Response time | Below 40 ms |
| Dimensions (H x L x W) | 111.5 x 45 x 99 mm |
| Supply | 24 Vdc plus or minus 15 percent, below 3 W without load |
| Relay rating (UL) | 230/240 Vac, 4 A general use, C300 pilot duty |
| Input circuits | 24 V, 5 mA; on at 12 to 24 V, off at 0 to 8 V |
| Environment | 0 to plus 55 degrees Celsius; IP40 housing, IP20 terminals |
| Approvals | EC type examination M6A 075157 0032, TUV SUD Z10 075157 0031, UL E131787 |
Where Pizzato CS MP204M0 sits in the CS MP 45 mm group
The CS MP201M0 shares the 3NO relay stage but has only 8 inputs and 8 test outputs. The CS MP203M0 has 12 inputs and a 3NO plus 1NO relay stage. The CS MP202M0 and CS MP208M0 have 16 inputs with semiconductor outputs. The CS MP206M0 has 8 inputs and 12 signalling outputs. So the code on this page is the choice for a machine with a dozen safety inputs that needs relay contacts but does not need a fourth contact, and the MTTFD of 134 years and PFHD of 1.52E-09 per hour are the values to use for the safety function calculation.
Relay or semiconductor outputs?
Relay contacts isolate the load galvanically, can switch ac loads up to the stated ratings, and give a visible, well-understood failure mode. Semiconductor outputs are quiet and fast but only for 24 Vdc loads. The module offers 3NO relay contacts rated at up to 230/240 Vac with 4 A general use for UL, so it can drive contactors directly in many cases. The signalling outputs remain semiconductor type and are not for safety functions. When a machine mixes a motor contactor, a valve at 24 V and a PLC signal, this combination of relay and signalling outputs is practical.
Typical uses
A packaging machine may have three door switches with two channels each, two emergency stops with two channels and a two-hand control with two channels, which already use twelve inputs. The program defines which device stops which part, and the three relay contacts disconnect the main contactor, the pneumatic valve and a drive. In Oman, such modules are used by machine builders and system integrators who ship equipment to oil, gas and food industry customers and need clear documentation.
Programming workflow
- Register on the manufacturer site and install Gemnis Studio.
- Place the sensors in the sensor zone and select their types and test lines.
- Connect them through function blocks to the relay and signalling outputs.
- Simulate the behaviour, load the program by USB and validate the machine.
- Print the connection and program reports and file them.
An example: three doors, two stops and a two-hand station
Take a twelve-input layout. Inputs 1 to 6 serve three door switches with two channels each, inputs 7 to 10 serve two emergency stop buttons, and inputs 11 and 12 serve a two-hand station treated as one tested pair. In the program, each door switch is a sensor with two tested channels, the emergency stops feed an AND block, and the outputs are formed with function blocks so that an open door stops only the cell it guards while an emergency stop opens all three relay contacts. The 4 signalling outputs show which door is open, and the test outputs supply the test pulses that let the module detect shorted or crossed channels. This kind of arrangement would need five or six conventional relays and a lot of jumpers.
Using the figures in a safety calculation
For a safety function built on this module, the designer takes the MTTFD and PFHD of the module, combines them with the data of the sensors and of the output contactors, and checks the architecture, diagnostic coverage and common cause factors according to EN ISO 13849-1. The mission time of 20 years is the period over which the figures are valid, after which the module should be replaced. The module data do not replace the calculation of the whole chain, and a high result for the logic does not help if the door switch has a low B10D or the contactors are not monitored.
Software functions worth knowing
Gemnis Studio provides a library of function blocks including AND, OR, XOR and their negations, delays, pulse generators, counters, triggers, external device monitoring and an error block. It can also generate a connection report that lists every terminal with its connected device, and a program report that documents the logic. A password protects the module against unwanted changes of the project, and the software can simulate the sensors on screen so that the logic can be shown to a customer or auditor before any wiring is done.
Installation data
Use 60 or 75 degrees Celsius copper conductors, 30 to 12 AWG, with 5 to 7 lb in tightening torque. The supply is protected by a PTC element and the self-test at start-up lasts less than 2 seconds. The total current of the signalling and test outputs may not exceed 0.5 A. Keep input cable capacitance within 470 nF.
Maintenance
Archive the program and password, repeat validation after changes and test relay outputs at the proof test interval. Replace a module that reports internal faults.
Related items you may also need: Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FR 1007 Position Switch, Adjustable Roller | All Pizzato products.
Pizzato CS MP204M0 ordering checklist
- When the Pizzato CS MP204M0 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
- Every enquiry for the Pizzato CS MP204M0 is answered with a written confirmation of the code, condition and expected lead time.
- Use the attached datasheet to check the Pizzato CS MP204M0 ratings, dimensions and connection details against your drawings.
- We supply the Pizzato CS MP204M0 as part of our safety switches & guard locking range to plants in Oman and the GCC.
- For critical duty, keeping one Pizzato CS MP204M0 as a site spare shortens downtime after a failure.
Documents and quotation
The Pizzato catalogue chapter of the CS MP programmable modules is attached to this page. For a quotation, send an RFQ with Pizzato CS MP204M0, the quantity and the delivery destination in Oman or the GCC.
Other Models in the CS MP Range
Seven Star LLC supplies models from the CS MP range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pizzato CS MP201M0 Programmable Safety Module, Gemnis | Safety Switches & Guard Locking | View details |
| Pizzato CS MP202M0 Programmable Safety Module, 16 Inputs | Safety Switches & Guard Locking | View details |
| Pizzato CS MP206M0 Programmable Safety Module, 12 Outputs | Safety Switches & Guard Locking | View details |
| Pizzato CS MP204M0 Programmable Safety Module, 12 Inputs | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet Pizzato CS MP204M0 Programmable Safety Module, 12 Inputs Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS MP204M0 Programmable Safety Module, 12
Answers from our engineering team on installation, compatibility and integration.
01How many inputs does the Pizzato CS MP204M0 have?
It has 12 safety inputs, 4 test outputs and 4 signalling outputs, plus a relay stage of three normally open safety contacts.
02What safety figures does the CS MP204M0 give?
MTTFD is 134 years, PFHD is 1.52E-09 per hour, mission time 20 years, within Maximum SIL 3, PL e and category 4.
03How is the CS MP204M0 programmed?
With Gemnis Studio over the USB port, using a graphical desktop with sensors, function blocks and a simulation before loading.
04What is the response time of the CS MP204M0?
The system response time is below 40 ms.
05What are the relay ratings of the CS MP204M0?
The UL rating is 230/240 Vac, 4 A general use, C300 pilot duty, and the supply is 24 Vdc below 3 W without load.


















Reviews