Brand: Pizzato
Pizzato CS AT-03V024 Safety Module, 3-30 s Delayed Contacts
Description
Overview
Heavy rotating equipment such as crusher rotors, large grinding wheels and big blowers can take tens of seconds to wind down, and for those machines a safety relay whose delayed contacts last only a few seconds is useless. The Pizzato CS AT-03V024 is the member of the Pizzato CS AT-0 family with the long adjustment range: its delayed contacts release after an adjustable time of 3 to 30 seconds, set in steps of 3 seconds. It also provides two instantaneous normally open safety contacts, one instantaneous normally closed contact for signalling and two delayed normally open safety contacts, runs from 24 V ac/dc and uses screw terminals. Seven Star LLC is an independent supplier serving Oman and the GCC.
Parameters of Pizzato CS AT-03V024
| Parameter | Catalogue value |
|---|---|
| Delay range (code 3) | 3 to 30 s in 3 s steps |
| Instantaneous outputs | 2NO safety, 1NC auxiliary, category 4 |
| Delayed outputs | 2NO safety, category 3 |
| Supply | 24 Vac/dc, 50 to 60 Hz, minus 10 to plus 15 percent |
| Consumption | Below 10 VA ac; below 5 W dc |
| Safety limits | SIL 3 and PL e |
| Inputs | 1 or 2 channels; contacts, magnetic sensors or OSSD |
| Start | Automatic, manual or monitored |
| Response tA | Below 300 ms |
| Release tR1 | Below 25 ms; without supply below 150 ms |
| Contact ratings | AC-15 3 A at 230 V; DC-13 4 A at 24 V; Ith 6 A |
| Squared currents | 72 A2 instantaneous, 36 A2 delayed |
| Fuse | 4 A |
| Housing | PA 66 V0; IP40; IP20 terminals; design C |
| Temperature | Minus 25 to plus 55 degrees Celsius |
Which delay code do I need?
The catalogue lists five choices for the first digit after AT-0. Code 0 is a fixed time defined by an option, such as TF0.5, TF1 or TF3. Code 1 is 0.3 to 3 seconds, code 2 is 1 to 10 seconds, code 3 is 3 to 30 seconds and code 4 is 30 to 300 seconds. To choose, measure the longest run-down time of the machine and select the lowest range that contains it with some margin. For a rotor that needs 18 seconds, code 3 fits and gives 3 second steps, while code 2 stops at 10 seconds and code 4 would be coarse at 30 second steps. This page covers code 3 only; codes 1 and 2 are covered by the sibling CS AT-01 and CS AT-02 pages.
Why Pizzato CS AT-03V024 suits big rotating machines
A gyratory crusher, a hammer mill, a centrifugal dryer or a large industrial fan stores a lot of energy. After the emergency stop, the drive is cut and the brake, if any, acts, but the rotor still turns. The instantaneous contacts of the module open at once and disconnect the drive; the delayed contacts stay closed for the set time and keep a guard lock engaged or a brake supply alive, then open. With a setting of, say, 21 seconds, the guard cannot be opened before the machine has been measured to be at rest. In arid Gulf climates dust loading on fans and mills adds mass, so the stop time should be measured in the dirtiest realistic state.
Selection and wiring tips
- Pick the 024 code when the cabinet has a 24 V ac/dc source; use the 120 or 230 versions for line voltage.
- Connect S11, S12 and S21, S22 to the two input channels, and wire the start circuit on S33 and S34.
- Use the instantaneous contacts 13 to 14 and 23 to 24 for the drive disconnection.
- Use the delayed contacts 47 to 48 and 57 to 58 for the lock or brake supply.
- Keep the 4 A fuse in the output circuit and the input cable resistance below 50 ohm.
Category 4 and category 3 in one module
The data sheet gives two categories for one module. The instantaneous contacts reach category 4, while the delayed contacts reach category 3, always within the SIL 3 and PL e limits of the module. In practice this means that the disconnection of the drive, which is the primary safety function, is carried by the instantaneous contacts and enjoys the higher category, whereas the delayed release of the lock is a function with a lower category that still has to be assessed. Take the figures into the calculation of each safety function separately and do not assign the delayed contacts to a function that needs category 4.
Common mistakes to avoid
The first mistake is choosing a delay by guess. A delay that is too short releases the guard while the rotor still turns, and one that is far too long invites operators to find ways around the guard. The second is wiring the delayed contacts to a load that should be disconnected at once. The third is forgetting that the dial can be turned by anyone with a screwdriver, so the setting should be secured by a seal, a label or a lockable cabinet and verified in each inspection. The fourth is assuming that the delay compensates for a missing brake: it only waits, it does not slow the machine.
Commissioning and checks
Time the stop with a stopwatch from the moment of the emergency stop to the moment the rotor is at rest, repeat it three times and take the longest value. Set the dial to the next step above it. Test that the instantaneous contacts open at once and the delayed contacts open at the set time. Document and repeat the test every year. If the machine is modified, for example by adding a heavier rotor, repeat the measurement and review the setting.
Service
The module has no serviceable parts. Compare the dial position with the machine record at each inspection and replace the unit if the timing differs from the setting or contacts show damage.
Related items you may also need: Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FD 1001 Metal Position Switch with Plunger | All Pizzato products.
Checklist before ordering the Pizzato CS AT-03V024
- Before ordering the Pizzato CS AT-03V024, compare the nameplate of the unit being replaced with the code shown on this page, character by character.
- Our team confirms the Pizzato CS AT-03V024 code, condition and lead time in writing before any order is placed.
- The datasheet attached to this page is the reference for the Pizzato CS AT-03V024 dimensions, ratings and wiring.
- The Pizzato CS AT-03V024 is listed in our safety switches & guard locking range and ships to sites across Oman and the GCC.
- Spare quantities of the Pizzato CS AT-03V024 are worth planning for critical duty so that a failure does not stop production.
Documents and quotation
The Pizzato catalogue sheet for the CS AT-0 family is attached to this page. To obtain a quotation, send an RFQ with Pizzato CS AT-03V024, the quantity and the delivery destination in Oman or the GCC, with the run-down time of your machine if you want us to check the range.
Other Models in the CS AT Range
Seven Star LLC supplies models from the CS AT range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pizzato CS AT-01V024 Safety Module with Delayed Contacts | Safety Switches & Guard Locking | View details |
| Pizzato CS AT-02V120 Timed Safety Module, 120 Vac | Safety Switches & Guard Locking | View details |
| Pizzato CS AT-03V024 Safety Module, 3-30 s Delayed Contacts | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet Pizzato CS AT-03V024 Safety Module, 3-30 s Delayed Contacts Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS AT-03V024 Safety Module, 3-30 s Delayed
Answers from our engineering team on installation, compatibility and integration.
01What delay range does the Pizzato CS AT-03V024 offer?
Delay code 3 gives an adjustable release time of 3 to 30 seconds in steps of 3 seconds for the two delayed contacts.
02How does the CS AT-03V024 differ from the CS AT-01V024?
Only the delay range: 3 to 30 seconds in 3 second steps instead of 0.3 to 3 seconds in 0.3 second steps; outputs and supply stay the same.
03What supply does the CS AT-03V024 use?
24 Vac/dc at 50 to 60 Hz, tolerance minus 10 to plus 15 percent, below 10 VA on ac or below 5 W on dc.
04Which outputs does the CS AT-03V024 have?
Two instantaneous normally open safety contacts, one instantaneous normally closed contact and two delayed normally open safety contacts.
05What are the response times of the CS AT-03V024?
Response time is below 300 ms and release time is below 25 ms, or below 150 ms when the supply is lost.


















Reviews