- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ifm
ifm SD0523 Compressed Air Meter, Clamp-on Pipe Style, G 1
Description
ifm SD0523 overview
The ifm SD0523 belongs to the older generation of compressed air meters from ifm and is sold by the manufacturer under the order description SDD11DGXFPKG/US-100. The manufacturer flags it as a phase-out article and points to the SD1540 as the alternative, adding that technical data and accessories may differ when you switch. What makes this variant unusual is its mounting concept: instead of a fixed pipe section it is adjusted to the inside diameter of the pipe it is installed in, anywhere between 38 and 254 mm, and the output scaling follows the diameter you enter. Its G 1 internal thread is the process fitting.
What the SD0523 measures and outputs
- Flow velocity from 0.5 to 143.9 m/s, shown with 0.1 m/s resolution, with set points available in m/s, m3/h or m3/min.
- A volume counter whose pulse value runs from 1 to 1000 x 10^3 normal cubic metres, useful for energy-per-cubic-metre reporting.
- Air temperature from 0 to 60 degC, with 0.2 K resolution on the display.
- Two PNP switching outputs, each rated up to 250 mA, plus a 4 to 20 mA analogue output that can be scaled between the analogue start and end points.
- IO-Link for parameter transfer, with a four-digit alphanumeric display and three status LEDs on the front.
SD0523 technical data
| Product type | Compressed air meter, flow plus temperature monitoring |
|---|---|
| Insertion style | Adjustable to inside pipe diameters of 38 to 254 mm |
| Process connection | G 1 internal thread |
| Measuring range (at 72 mm inside diameter) | 0.5 to 143.9 m/s, 8 to 2110 m3/h, 0.12 to 35.18 m3/min |
| Display range | 0 to 172.7 m/s, 0 to 2532 m3/h |
| Medium | Compressed air, 0 to 60 degC |
| Pressure rating | 16 bar |
| Operating voltage | 18 to 30 V DC (SELV/PELV), under 110 mA |
| Outputs | 2 digital PNP up to 250 mA each, 1 analogue 4 to 20 mA (load up to 500 ohm), pulse output, IO-Link |
| Repeatability | plus/minus 1.5 percent of measured value |
| Accuracy at 72 mm | plus/minus (6 percent MW + 0.6 percent MEW) |
| Temperature accuracy | plus/minus 2.5 K for flow above 2 Nm3/h |
| Response time | 0.1 s (damping 0) |
| Pulse value | 1 to 1000 x 10^3, in steps of 1 Nm3 |
| Housing | PBT-GF20, PC, stainless steel 304 and FKM; 114.1 x 45 x 98.2 mm |
| Wetted parts | Stainless steel 316 (1.4401) and 304 |
| Weight / protection | 539.5 g, IP 65 |
| MTTF | 213 years |
Read as running text, the manufacturer datasheet of the SD0523 states the following. Product type: Compressed air meter, flow plus temperature monitoring. Insertion style: Adjustable to inside pipe diameters of 38 to 254 mm. Process connection: G 1 internal thread. Measuring range (at 72 mm inside diameter): 0.5 to 143.9 m/s, 8 to 2110 m3/h, 0.12 to 35.18 m3/min. Display range: 0 to 172.7 m/s, 0 to 2532 m3/h. Medium: Compressed air, 0 to 60 degC. Pressure rating: 16 bar. Operating voltage: 18 to 30 V DC (SELV/PELV), under 110 mA. Outputs: 2 digital PNP up to 250 mA each, 1 analogue 4 to 20 mA (load up to 500 ohm), pulse output, IO-Link. Repeatability: plus/minus 1.5 percent of measured value. Accuracy at 72 mm: plus/minus (6 percent MW + 0.6 percent MEW). Temperature accuracy: plus/minus 2.5 K for flow above 2 Nm3/h. Response time: 0.1 s (damping 0). Pulse value: 1 to 1000 x 10^3, in steps of 1 Nm3. Housing: PBT-GF20, PC, stainless steel 304 and FKM; 114.1 x 45 x 98.2 mm. Wetted parts: Stainless steel 316 (1.4401) and 304. Weight / protection: 539.5 g, IP 65. MTTF: 213 years.
Where the SD0523 earns its keep
A meter whose size follows the pipe suits plants where line diameters vary or where older ring mains were never standardised. In Omani refineries, gas plants and fabrication yards, compressed air headers often grew in stages, with DN40, DN80 and 150 mm branches side by side. One SD0523 can be specified for a mixed fleet, provided the application is within 38 to 254 mm and the medium is compressed air. It is also a practical spare for maintenance teams who need the same device type on several pipe sizes, and for utilities engineers benchmarking consumption of blowers and dryers.
How SD0523 differs from other SD air meters
Most SD meters have a fixed measuring tube; the SD0523 does not. Compare it with the SD2500 (R 2, 40 to 11670 l/min, fixed tube), the SD5000 (G 1/4, 1 to 250 l/min) and the SD9000 (R 1 1/2, 20 to 6835 l/min): each has one fixed range, whereas the SD0523 scales up to 2110 m3/h at its stated reference diameter of 72 mm. The accuracy statement is also different, plus/minus 6 percent of reading plus 0.6 percent of full scale at 72 mm, because the sensing rod sits in an adjustable position. Its supply current is under 110 mA, its pressure rating is 16 bar and its enclosure is IP 65.
Installation notes for SD0523
Choose the entry point so that straight pipe runs before and after the rod follow the guidance in the manufacturer datasheet, set the inside diameter in the menu, and confirm direction. Keep supply within 18 to 30 V DC and use cable suited to the output you intend to read. Because the rod penetrates the pipe, depressurise the line and follow lock-out procedures before opening the fitting, and refit the seal supplied with the process connection.
Maintenance and checks
Look for condensate or oil film on the sensing element at each shutdown, since contamination changes thermal transfer. Wipe only with a lint-free cloth. Check the analogue loop against a handheld at commissioning and annually, and keep a record of the diameter parameter, because an incorrect value changes every flow reading by the same ratio.
Related products and replacement notes
If the SD0523 cannot be sourced you can compare it with the SD1540 named by the manufacturer. Because dimensions and ranges may differ, request the new datasheet before changing a design. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; part numbers are quoted exactly as shown in the manufacturer literature.
Frequently asked questions about the SD0523
- What is the ifm SD0523 used for? The ifm SD0523 is a compressed air meter that reports flow velocity, volume consumed and air temperature, and has two switching outputs plus a 4 to 20 mA output.
- What pipe sizes can the SD0523 be adjusted to? The datasheet states it is adjustable to inside pipe diameters from 38 to 254 mm, and the stated measuring range of 8 to 2110 cubic metres per hour is given for a 72 mm inside diameter.
- Is the ifm SD0523 still in production? The manufacturer lists the SD0523 as a phase-out article and names the SD1540 as an alternative; check the new datasheet for differing technical data before replacing it.
- What is the process connection and rating of the SD0523? It has a G 1 internal thread, a pressure rating of 16 bar, a medium temperature of 0 to 60 degrees Celsius and protection class IP 65.
- How do I request a quotation for ifm SD0523 from Seven Star LLC? Send the part number SD0523, the quantity and your delivery location through the RFQ form; we confirm availability and reply with a quotation.
Documents and quotation
The manufacturer datasheet for the SD0523 is attached to this page and is the reference for every value above. To order, send the RFQ with part number SD0523 and the quantity, plus delivery location and any application details, and our team will check availability and reply with a quotation.
Other Models in the SD Range
Seven Star LLC supplies models from the SD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ifm SD6600 Industrial Gas Counter, R 1/2 DN15, IO-Link | Thermal Mass Flow Meters & Controllers | View details |
| ifm SD8500 Compressed Air Meter, R 1 DN25, IO-Link | Thermal Mass Flow Meters & Controllers | View details |
| ifm SD2500 Compressed Air Meter, R 2 DN50, IO-Link | Thermal Mass Flow Meters & Controllers | View details |
| ifm SD0523 Compressed Air Meter, Clamp-on Pipe Style, G 1 | Thermal Mass Flow Meters & Controllers | You are viewing this model |
Datasheets & Documents
- Datasheet ifm SD0523 Compressed Air Meter, Clamp-on Pipe Style, G 1 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.
Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.
ifm company profile
| Founded | 1969, Essen, Germany |
|---|---|
| Founders | Robert Buck and Gerd Marhofer |
| Headquarters | Essen, Germany |
| Ownership | Family-owned |
| Product families | Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters |
Milestones
- 1969: ifm is founded in Essen.
- 2001: The founders' sons take over management.
ifm sensors listed on this page
ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:
- O1D100: laser distance sensor for position and distance measurement
- PN7093: pressure sensor with local display
- NG5021: inductive proximity sensor with NAMUR output
Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.
ifm products we list
Ordering ifm sensors: what we need
Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.
Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.
Browse ifm products by category: Sensors & Transmitters, Pressure Instrumentation.
FAQ
Questions about the ifm SD0523 Compressed Air Meter, Clamp-on Pipe
Answers from our engineering team on installation, compatibility and integration.
01What is the ifm SD0523 used for?
The ifm SD0523 is a compressed air meter that reports flow velocity, volume consumed and air temperature, and has two switching outputs plus a 4 to 20 mA output.
02What pipe sizes can the SD0523 be adjusted to?
The datasheet states it is adjustable to inside pipe diameters from 38 to 254 mm, and the stated measuring range of 8 to 2110 cubic metres per hour is given for a 72 mm inside diameter.
03Is the ifm SD0523 still in production?
The manufacturer lists the SD0523 as a phase-out article and names the SD1540 as an alternative; check the new datasheet for differing technical data before replacing it.
04What is the process connection and rating of the SD0523?
It has a G 1 internal thread, a pressure rating of 16 bar, a medium temperature of 0 to 60 degrees Celsius and protection class IP 65.
05How do I request a quotation for ifm SD0523 from Seven Star LLC?
Send the part number SD0523, the quantity and your delivery location through the RFQ form; we confirm availability and reply with a quotation.


















Reviews