Brand: Magnetrol
Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 Kynar
Description
Magnetrol 089-9126-004: Transducer replacement kit for the Echotel 355
Ultrasonic transducers fail quietly: a cracked face, a water-logged cable or a contaminated surface and the level reading drifts. The Magnetrol 089-9126-004 is the kit that replaces the transducer on an Echotel 355 that has the cast aluminum housing, M20 conduit entries, FM intrinsically safe approval and a Kynar Flex (PVDF) face.
In the long parts table of manual 51-661 this kit is the fourth line of the aluminum-base list. The order is deliberate: the first two lines are the 3/4 inch NPT conduit versions, then the M20 versions, with polypropylene before Kynar. A buyer therefore reads 089-9126-004 as “FM, M20, Kynar”. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of 089-9126-004
- Replaces the complete transducer of a Model 355 with an aluminum housing base.
- Kynar Flex (PVDF) face with 2 inch NPT process thread.
- M20 cable entries matched to the transmitter conduit code 1.
- Rated for -40 to +80 C process and 0 to 3 bar.
- Preserves the 10 degree beam and 60 kHz operating frequency of the Model 355.
Technical specifications of 089-9126-004
| Parameter | Value |
|---|---|
| Part number | 089-9126-004 |
| Kit type | Transducer replacement kit, cast aluminum housing base |
| Approvals | FM intrinsically safe and non-incendive (cFMus) |
| Conduit connections | M20 |
| Transducer material | Kynar Flex (PVDF) |
| Manual reference | Section 3.4.1 item 4 |
| Echotel 355 transducer data | Value |
|---|---|
| Maximum range | 20 feet (6 m) under ideal conditions |
| Minimum range | 13 inches (330 mm) |
| Blocking distance | 10 inches (250 mm) |
| Frequency | 60 kHz |
| Beam angle | 10 degree conical |
| Process connection | 2 inch NPT |
| Process temperature | -40 to +175 F (-40 to +80 C) |
| Process pressure | 0 to 43.5 psig (0 to 3 bar) |
| Accuracy | Greater of 0.2 percent of range or 0.24 inch (6 mm) |
| Repeatability | 0.125 inch (3 mm) |
| Resolution | 0.1 inch (2.5 mm) |
| Output | 4 to 20 mA, optional HART, 3.8 to 20.5 mA usable (NAMUR NE 43) |
| Minimum measurement | 3 inches (76 mm) |
| Linearity | 0.4 inch (10 mm) |
| Response time | Less than 1 second, typical |
| Warm-up time | 25 seconds |
| Display | 2-line by 16-character LCD with 4-button keypad |
| Diagnostic alarm | Selectable 3.6 mA, 22 mA or HOLD |
| Power consumption | Less than 1 watt |
Typical uses of 089-9126-004 in oil and gas, utilities, water and manufacturing
The Kynar Flex face is the version recommended where the liquid or the vapor above it attacks polypropylene, such as many chemicals in water treatment and process tanks. The manual warns that the thermoplastic transducer should not be used in liquids containing esters or ketones, which applies to both materials.
M20 conduit entries are common on European-standard panels and skid wiring, so this kit is likely to turn up on imported packages in Omani plants. Level of treated water, sump, caustic and acid day tanks are typical duties for the 355 in the 20 foot range.
How 089-9126-004 differs from other Echotel 355 transducer kits
| Kit | Difference |
|---|---|
| 089-9126-001 | FM, 3/4 NPT conduit, polypropylene |
| 089-9126-002 | FM, 3/4 NPT conduit, Kynar |
| 089-9126-003 | FM, M20 conduit, polypropylene |
| 089-9126-004 | FM, M20 conduit, Kynar (this part) |
| 089-9126-010 | ATEX IS, M20, Kynar |
Compared with 089-9126-003 the face material changes from polypropylene to Kynar Flex; compared with 089-9126-002 the conduit thread changes from 3/4 inch NPT to M20. Neither change alters the 2 inch NPT process thread, the 60 kHz frequency or the 20 foot range, so the electrical thread and chemical resistance are the points to confirm.
Selection and compatibility for 089-9126-004
- Housing: cast aluminum base (the Lexan-base twin is 089-9126-016).
- Approvals: FM intrinsically safe and non-incendive (cFMus).
- Conduits: M20, shown in housing code 1 of the model number.
- Transducer: R, 2 inch NPT Kynar Flex.
- Read the full model number on the nameplate before ordering.
Practical notes for 089-9126-004
When the transducer of a 355 is changed, the measurement itself is not recalibrated at the factory: the unit works purely as a time-of-flight device on the speed of sound, which the manual sets at 331.45 m/s at 0 C and corrects for temperature. A new Kynar Flex face therefore needs no span adjustment, but the configured Range, Level Offset and Trim Level (limited to plus or minus 10 inches) should be reviewed afterwards.
The Kynar Flex material (PVDF) is chosen where polypropylene would swell, and the manual still lists esters and ketones as media to avoid for thermoplastic transducers. Check the chemistry of the vapor space, not only the liquid.
Installation and commissioning of 089-9126-004
The manual cautions that the unit should only be hand-tightened into the process connection, since overtightening can cause transducer errors and void the warranty. Remove the black protective cap from the end of the transducer, mount the face parallel to the liquid surface within 2 to 3 degrees, and keep the face at least 10 inches (250 mm) above the highest expected level.
After a transducer swap, check the Range and Blocking Distance in the configuration (the factory defaults are 240 inches and 10 inches) and run the Echo Profile to confirm the correct target.
Maintenance and spares planning
Keep one transducer kit per type of transmitter in the maintenance store. Plan a visual inspection of the transducer face whenever a tank is emptied, and clean it with a method that suits the plastic. Record 089-9126-004 against the tag number so you can replace like for like.
Documents and quotation
The manufacturer manual 51-661 for the Echotel Model 355 is attached to this page as the datasheet for 089-9126-004; its section 3.4 holds the parts table and section 3.6 the specifications used above. To receive a quotation, send an RFQ giving part number 089-9126-004, quantity, the model number printed on the transmitter nameplate and the delivery location in Oman or the GCC.
What to Include in Your Magnetrol 089-9126-004 Enquiry
An accurate quotation for the Magnetrol 089-9126-004 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing ultrasonic level transmitters and reply with availability and a realistic delivery estimate.
Other Models in the Magnetrol 355 Range
Seven Star LLC supplies models from the Magnetrol 355 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol 089-9125-003 HART Electronic Module for Echotel 355 | Level Switches | View details |
| Magnetrol 089-9126-001 Echotel 355 Transducer Kit, Polypropylene | Level Switches | View details |
| Magnetrol 089-9126-016 Echotel 355 Transducer Kit Lexan FM M20 Kynar | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 Kynar | Ultrasonic Level Transmitters | You are viewing this model |
| Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PP | Ultrasonic Level Transmitters | View details |
| Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPT | Ultrasonic Level Transmitters | View details |
Datasheets & Documents
- Datasheet Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 Kynar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol 089-9126-004 Echotel 355 Transducer Kit
Answers from our engineering team on installation, compatibility and integration.
01What is Magnetrol 089-9126-004?
It is the transducer replacement kit for the Echotel Model 355 with cast aluminum housing base, FM intrinsically safe and non-incendive approvals, M20 conduits and a Kynar Flex transducer.
02What process connection does the 355 transducer have?
The manual lists a 2 inch NPT process connection, with a process pressure of 0 to 43.5 psig (3 bar).
03What is the process temperature range of the transducer?
The manual gives -40 to +175 F (-40 to +80 C).
04Which kit is the polypropylene version of the same configuration?
The polypropylene transducer with FM approvals and M20 conduits on an aluminum base is 089-9126-003.
05Can Seven Star LLC quote 089-9126-004?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.