Magnetrol 089-9126-016: Transducer kit for Lexan-housed Echotel 355

Not every Echotel 355 has a cast aluminum housing. The Lexan version is a light plastic enclosure, popular on water, wastewater and chemical tanks where metal corrodes, and its transducer kits are listed separately in the manual. Magnetrol 089-9126-016 is the kit for the Lexan base with FM approval, M20 conduits and a Kynar Flex transducer.

The Lexan list has only eight kits, numbered 089-9126-013 to 089-9126-020, while the aluminum list has ten. That makes 089-9126-016 the fourth entry of the Lexan series, in the same position that 089-9126-004 takes in the aluminum series. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of 089-9126-016

  • Fits the Lexan plastic housing base of the Echotel 355.
  • FM intrinsically safe and non-incendive approvals.
  • Kynar Flex transducer on a 2 inch NPT thread.
  • M20 conduits.
  • Suited to corrosive atmospheres where aluminum is avoided.

Technical specifications of 089-9126-016

Parameter Value
Part number 089-9126-016
Kit type Transducer replacement kit, Lexan (plastic) housing base
Approvals FM intrinsically safe and non-incendive
Conduit connections M20
Transducer material Kynar Flex (PVDF)
Housing note Lexan housing used as end of line, one conduit entry plugged
Housing ingress rating IP67 for the Lexan enclosure (IP66 for metal)
Manual reference Section 3.4.1, Lexan housing base list
Echotel 355 transducer data Value
Maximum range 20 feet (6 m) under ideal conditions
Minimum range 13 inches (330 mm)
Blocking distance 10 inches (250 mm)
Frequency 60 kHz
Beam angle 10 degree conical
Process connection 2 inch NPT
Process temperature -40 to +175 F (-40 to +80 C)
Process pressure 0 to 43.5 psig (0 to 3 bar)
Accuracy Greater of 0.2 percent of range or 0.24 inch (6 mm)
Repeatability 0.125 inch (3 mm)
Resolution 0.1 inch (2.5 mm)
Output 4 to 20 mA, optional HART, 3.8 to 20.5 mA usable (NAMUR NE 43)
Minimum measurement 3 inches (76 mm)
Linearity 0.4 inch (10 mm)
Response time Less than 1 second, typical
Warm-up time 25 seconds
Display 2-line by 16-character LCD with 4-button keypad
Diagnostic alarm Selectable 3.6 mA, 22 mA or HOLD
Power consumption Less than 1 watt

Typical uses of 089-9126-016 in oil and gas, utilities, water and manufacturing

The manual gives two instructions for the Lexan housing: it should only be used as end of line, with one conduit entry plugged, and if cable glands are used they should be non-metallic. These are exactly the details that surface in a refit and should be checked at the time of replacement.

Typical sites are wastewater pump stations, desalination chemical dosing tanks, brine sumps and cooling tower basins in the GCC, where aggressive atmospheres attack aluminum and the Lexan housing avoids corrosion.

How 089-9126-016 differs from other Echotel 355 transducer kits

Kit Difference
089-9126-013 Lexan base, FM, 3/4 NPT, polypropylene
089-9126-014 Lexan base, FM, 3/4 NPT, Kynar
089-9126-015 Lexan base, FM, M20, polypropylene
089-9126-016 Lexan base, FM, M20, Kynar (this part)
089-9126-004 Aluminum base twin with the same approvals and plastic

Compared with 089-9126-004, the only change is the housing base (Lexan instead of cast aluminum), so the kit does not interchange between housings. Compared with 089-9126-015 the face material is Kynar instead of polypropylene. The Lexan base has no ATEX XP kits at all.

Selection and compatibility for 089-9126-016

  • Housing: Lexan plastic base (housing code 6 in the model number has 3/4 inch NPT, so check the M20 conduit on the nameplate).
  • Approvals: FM intrinsically safe and non-incendive.
  • Transducer: Kynar Flex, 2 inch NPT.
  • Use non-metallic glands.

Practical notes for 089-9126-016

A plastic Lexan housing is lighter and often easier to handle on a tank roof than a cast aluminum one, and the 355 in this construction has a stated ingress rating of IP67 where the metal housing is IP66. The conduit rule matters: one entry must be plugged and the unit used as the last device on the cable run.

The spare parts list for the Lexan housing also includes its own cover, 003-1226-003, and O-ring, 012-2616-001. The same cover and O-ring numbers are not interchangeable with the aluminum parts 036-4410-010 and 012-2201-237.

If the tank sits outdoors in Oman, treat the plastic housing as a part with a service life: inspect the clear lens and cover seal for sun damage once a year and plan a shade if the manual warning about intense direct sunshine applies to your site.

Installation and commissioning of 089-9126-016

Hand-tighten the 2 inch NPT transducer thread and do not use a wrench on the plastic. Point the face down, level, and parallel to the surface within 2 to 3 degrees; avoid strong direct sunshine, which the manual notes can overheat the unit, using a sunshade where needed.

After mounting, do a bench-style check by aiming at a stable target 2 to 4 feet (610 to 1220 mm) away; the manual describes watching the display for one to two minutes.

Maintenance and spares planning

A Lexan housing is less rugged than aluminum, so look for cracks near the conduit entries and for UV fading on outdoor tanks. Replace the transducer kit as a unit and keep the cover O-ring 012-2616-001 ready for the housing.

Documents and quotation

The manufacturer manual 51-661 for the Echotel Model 355 is attached to this page as the datasheet for 089-9126-016; its section 3.4 holds the parts table and section 3.6 the specifications used above. To receive a quotation, send an RFQ giving part number 089-9126-016, quantity, the model number printed on the transmitter nameplate and the delivery location in Oman or the GCC.

Delivery to Sites in Oman and the GCC

Delivery of the Magnetrol 089-9126-016 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive ultrasonic level transmitters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Other Models in the Magnetrol 355 Range

Seven Star LLC supplies models from the Magnetrol 355 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol 089-9125-003 HART Electronic Module for Echotel 355Level SwitchesView details
Magnetrol 089-9126-001 Echotel 355 Transducer Kit, PolypropyleneLevel SwitchesView details
Magnetrol 089-9126-016 Echotel 355 Transducer Kit Lexan FM M20 KynarUltrasonic Level TransmittersYou are viewing this model
Magnetrol 089-9126-004 Echotel 355 Transducer Kit FM M20 KynarUltrasonic Level TransmittersView details
Magnetrol 089-9126-009 Echotel 355 Transducer Kit ATEX IS M20 PPUltrasonic Level TransmittersView details
Magnetrol 089-9126-011 Echotel 355 Transducer Kit ATEX XP 3/4 NPTUltrasonic Level TransmittersView details
Datasheets & Documents
  • PDF Datasheet Magnetrol 089-9126-016 Echotel 355 Transducer Kit Lexan FM M20 Kynar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol 089-9126-016 Echotel 355 Transducer Kit

Answers from our engineering team on installation, compatibility and integration.

01What is Magnetrol 089-9126-016?
It is the transducer replacement kit for the Lexan-housed Echotel 355 with FM approvals, M20 conduits and a Kynar Flex transducer.
02Why does the Lexan housing need non-metallic glands?
The manual states that if cable glands are used with the Lexan housing they should be non-metallic, and that the housing should be used only as end of line.
03How many transducer kits are listed for the Lexan base?
Eight, numbered 089-9126-013 to 089-9126-020, covering FM and ATEX IS versions in both conduit threads and both plastics.
04Is there an XP kit for the Lexan base?
No. The manual lists the ATEX XP kits only for the cast aluminum base.
05Can Seven Star LLC supply 089-9126-016 in Oman?