Description

Hanna HI764080 edge Compatible Digital DO/Temperature Electrode overview

Hanna Instruments HI764080 is the part number of the edge Compatible Digital DO/Temperature Electrode. This page summarises what the maker publishes for HI764080, so that maintenance teams, laboratory managers and procurement staff in Oman and the GCC can check the key parameters before sending a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Every figure below comes from the published product information and should be confirmed against the current documentation for your instrument and application.

A dissolved oxygen sensor measures how much oxygen is available in water, which is a basic indicator of biological activity and treatment performance. The sensing membrane is a wear item, so spare parts and exact sensor identification matter in service work. Probes and electrodes are consumables: they age with use, so buyers often search for the exact order code such as HI764080 to replace a unit on an installed meter without changing the measuring method that was validated on site.

Key features of HI764080

  • Body material: PEI.
  • Connection: 3.5 mm connector.
  • Measuring range: 0 to 300% oxygen saturation.
  • Operating temperature: 0 to 50°C (32 to 122°F).
  • Cable: 1 m (3.3′).
  • Recommended use: edge multiparameter.

Technical specifications of HI764080

The table lists the values printed by the manufacturer for HI764080. Entries that the maker does not publish have been left out instead of estimated.

Parameter Value
Part number Hanna HI764080
Reference Ag/AgCl, glass encapsulated platinum
Measuring range 0 to 300% oxygen saturation
Operating temperature 0 to 50°C (32 to 122°F)
Tip shape polarographic membrane
Body length 120 mm
Temperature sensor yes
Built-in amplifier no
Body material PEI
Cable 1 m (3.3′)
Connection 3.5 mm connector
Recommended use edge multiparameter

Reading the HI764080 data

Hanna HI764080 is described in the table as a polarographic membrane sensor. Because it is a membrane based sensor, spare membranes and the correct maintenance procedure should be planned together with the probe itself.

Typical applications of HI764080 in Oman and the GCC

Water quality and process chemistry measurements are routine in the region. In oil and gas facilities the water laboratory checks boiler feed, produced water treatment, cooling water and effluent. Utilities and desalination plants monitor raw water, product water and chemical dosing steps. Municipal wastewater works, food and beverage plants and general manufacturing use similar sensors for quality control. The maker lists the following recommended use for HI764080: edge multiparameter. Hot ambient conditions make careful storage and regular calibration particularly important, because dry or overheated sensing elements age quickly.

Selection and compatibility notes for HI764080

Before ordering HI764080, confirm three points. First, the connector: the table shows 3.5 mm connector, and it must match the meter input, because BNC, DIN, quick connect DIN, banana and 3.5 mm styles are not interchangeable. Second, the sample: compare the temperature and pressure limits and the body material with your process. Third, the measuring task: models in the same family differ in tip shape, junction, electrolyte and amplifier, so a similar looking code can behave differently. If you are replacing an existing electrode, quote the code printed on the old one together with the meter model, and mention if an alternative is acceptable.

Installation and commissioning of HI764080

Remove the protective cap or soaking bottle if one is fitted, rinse the sensor with clean water and connect it to the instrument before switching it on. Calibrate with fresh standards that bracket the expected values, using the procedure of the meter in use, and note the slope or offset after commissioning. For HI764080 keep the cable away from power cables and motors, and do not bend the coaxial or multi-pole cable sharply, since cable damage is a frequent source of unstable readings.

Maintenance and storage for HI764080

Keep sensing elements wet in the storage or soaking solution recommended by the maker, clean them with a suitable cleaning solution when the response slows, and replace the sensor when calibration can no longer be achieved. Rinse between samples and avoid touching glass or metal surfaces. Record the date of installation and the calibration results so the working life of HI764080 in your application is known, and keep one spare of the exact code in a cool, clean store for planned outages.

Good measurement practice for sensors of this type

Reliable results depend as much on routine as on hardware. Use fresh calibration standards, store opened bottles tightly closed, and discard standards that have been contaminated by dipping a wet sensor. Allow the reading to stabilise before accepting a value, because a drifting display usually means the sensor has not reached equilibrium with the sample or the temperature. Record the sample temperature, since most chemical measurements change with it. In hot climates samples left in a vehicle can warm quickly, so measure on site wherever possible and keep sensors out of direct sun. When a sensor shows a slow response, a low slope, a large offset or noisy readings, clean it, recalibrate, and only then consider replacement. Keep a simple log for each measuring point that lists the sensor code, installation date, cleaning dates and calibration results. Such a log makes it easy to see whether a failure is caused by the sample, by handling or by ordinary ageing, and it supports audits in laboratories that follow quality systems. Training operators to rinse, blot and store sensors correctly is usually the cheapest way to extend sensor life and to reduce repeat purchases.

Related products and ordering notes for HI764080

Hanna Instruments offers many electrodes that differ only by connector, body material or junction, so the part number is the only reliable identifier. Alongside HI764080 we can quote related buffers, storage and cleaning solutions, reference electrodes and meters when you are reviewing a whole measuring point. Availability and lead time are confirmed per request, and no price is shown on this page.

Frequently asked points about HI764080

  • What is HI764080? It is the part number of the edge Compatible Digital DO/Temperature Electrode.
  • Which connector does it use? 3.5 mm connector.
  • What is the stated temperature range? 0 to 50°C (32 to 122°F).
  • How do I order? Send the RFQ with the part number HI764080 and the required quantity.

Documents and quotation

The official Hanna Instruments edge pH, EC and DO Meter Instruction Manual (HI2020, HI2030, HI2040) is attached to this page as a PDF. Page 5 of the manual describes HI764080 as the digital polarographic dissolved oxygen probe with integrated temperature sensor, and page 54 explains that DO concentration and % saturation readings on edge are made with the HI764080 probe, with salinity and altitude compensation set in SETUP. Quote HI764080 and your meter or controller model in your request so we can check the match before we send a written quotation.

Datasheets & Documents
  • PDF Datasheet Hanna edge pH / EC / DO Meter Instruction Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna Instruments HI764080 Dissolved oxygen sensor

Answers from our engineering team on installation, compatibility and integration.

01What is Hanna Instruments HI764080?
HI764080 is the part number of the edge Compatible Digital DO/Temperature Electrode, as listed by the manufacturer.
02What connector does HI764080 use?
The manufacturer lists the connection as 3.5 mm connector.
03What temperature range is stated for HI764080?
The manufacturer states 0 to 50°C (32 to 122°F) for this item.
04What is HI764080 recommended for?
The maker lists the following use: edge multiparameter.
05How do I request a quote for HI764080?
Send an RFQ to Seven Star LLC with the part number HI764080 and quantity. We are an independent supplier and not affiliated with the manufacturer.