Brand:

ifm SI5004 Flow Transmitter, 4-20 mA Analogue Output, 300 bar

Description

ifm SI5004 overview

The ifm SI5004 turns the flow monitor housing into a continuous flow transmitter for liquids. Instead of a switch point it delivers an analogue current of 4 to 20 mA across a setting range of 3 to 300 cm/s, so a PLC or panel meter can trend flow velocity rather than only detecting its presence. The pressure rating is 300 bar and the datasheet gives a maximum allowable working pressure of 208 bar for CRN applications. Ordering description: SID10ADB10OG/.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list this device so that maintenance, procurement and project teams can quote the exact part number against the manufacturer data.

Key features of the SI5004

  • Analogue current output 4 to 20 mA with a maximum load of 500 ohm and overload protection.
  • Suitable for liquids only, medium temperature minus 25 to plus 80 degrees Celsius.
  • Pressure rating 300 bar; MAWP 208 bar according to CRN.
  • Measuring error stated as plus or minus 2 to 10 percent of the final value, with 1 to 5 cm/s repeatability.
  • Probe length 45 mm, diameter 8.2 mm, wetted parts in stainless steel 316L with FKM seal.

SI5004 technical specifications

Parameter Value from the manufacturer datasheet
Number of inputs and outputs Number of analogue outputs: 1
Process connection threaded connection M18 x 1,5 internal thread
Media Liquids
Medium temperature [°C] -25…80
Pressure rating 300 bar 30 MPa
Operating voltage [V] 19…36 DC
Current consumption [mA] less than 60
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 10
Total number of outputs 1
Output signal analogue signal
Number of analogue outputs 1
Analogue current output [mA] 4…20
Max. load [Ω] 500
Overload protection yes
Probe length L [mm] 45
Setting range [cm/s] 3…300
Greatest sensitivity [cm/s] 3…100
Repeatability [cm/s] 1…5
Note on repeatability for water 5…100 cm/s; 25 °C
Temperature drift [cm/s x 1/K] 0.1; (for water 5…100 cm/s; 10…70 °C)
Response time [s] 1…10
Ambient temperature [°C] -25…80
Storage temperature [°C] -25…100
Protection IP 67
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (55…2000 Hz)
MTTF [years] 259
Weight [g] 230
Housing cylindrical
Dimensions [mm] Ø 50 / L = 113
Materials stainless steel (316L/1.4404); stainless steel (304/1.4301); PC; PBT-GF20; EPDM/X
Materials (wetted parts) stainless steel (316L/1.4404); O-ring: FKM 80 Shore A
Probe diameter [mm] 8.2
Installation length EL [mm] 45
Display function 10 x LED, three-colour

All values above are taken from the manufacturer datasheet for the SI5004. Ranges are written with three dots, for example 18…30 means 18 to 30. Where a limit depends on the medium or the installation, the datasheet condition applies.

Typical applications in oil and gas, utilities, water and manufacturing

Typical uses in the region include protecting pumps and heat exchangers against dry running or loss of cooling water, proving circulation in lube-oil, seal-water and chilled-water loops, and detecting flow of liquids or gases in utility headers on process skids, compressor packages and water treatment plants.

In Oman and the wider GCC, flow monitoring devices like the SI5004 are found in pump protection, cooling-water proving and utility flow supervision. Hot ambient conditions, dust and long cable runs make a sensor with clear local indication and stable outputs valuable, because it shortens fault finding for the shift technician. Check the ambient and medium temperature limits in the table above against the actual site conditions before selecting the device.

Selection and compatibility notes for the SI5004

The SI5004 is for liquid media; it is not rated for gases. When the process only needs a go or no-go flow alarm, the switching SI5000 or SI5010 is the simpler choice. The older SI1004 is listed by the manufacturer as no longer available and names the SI5004 as its alternative, but the datasheet warns that technical data may differ, so compare the setting range before swapping.

When you match this device to an existing loop, compare the supply voltage, output type, connector and process connection with the installed device, and confirm that the control system input accepts the signal. Because the part number identifies one exact version in the family, a similar-looking sibling can differ in output polarity, range or thread, and it is better to quote the exact designation than a family name.

Installation and commissioning

The probe must sit in the flow with its sensing end fully immersed in the medium, in a straight pipe section away from valves, elbows and pumps, so that the flow profile is stable. Use the tightening torque shown on the datasheet drawing and a suitable process adapter. After installation, set the switch point or analogue range under real flow conditions rather than relying on factory settings, and note the setting in the maintenance log.

Before power-up, check the wiring against the connection diagram in the datasheet, and after power-up allow any start-up delay listed in the table to elapse before judging the output. Document the settings made on site together with the serial number so that a replacement can be configured identically.

Maintenance and service

Check the probe for deposits, scale or oil film at the intervals the process demands, because coating on a probe can shift the response. Verify the switch point during planned shutdowns, inspect the O-ring and the M12 connector for damage, and keep a spare cable on the shelf.

Related products and ordering notes

Related ifm devices already listed in the Seven Star catalogue can be found through the brand page. When you request this device, please state the quantity, the required delivery location and whether a datasheet copy is needed. If the application is critical, tell us the process medium, pressure and temperature so the engineer can check the data before the quotation is prepared.

Frequently asked questions

  • What is the ifm SI5004? The ifm SI5004 is a flow transmitter with a 4-20 mA analogue output. The ifm SI5004 turns the flow monitor housing into a continuous flow transmitter for liquids.
  • What supply and protection rating does the SI5004 have? According to the manufacturer datasheet the SI5004 operates from 19…36 DC and has protection III.
  • Is the SI5004 still available from the manufacturer? The manufacturer datasheet does not carry a phase-out or archive notice, but availability changes over time, so ask us to confirm stock and lead time when you send the RFQ.
  • Does Seven Star LLC supply the SI5004 in Oman? Yes, Seven Star LLC quotes the SI5004 for projects and maintenance in Oman and the GCC. Send the part number SI5004 and the quantity and we will respond with availability.
  • How do I get a quotation for the SI5004? Use the RFQ form on this page with the part number SI5004, the quantity and your delivery location. We will reply with a quotation after checking availability.

Documents and quotation

The manufacturer datasheet is attached to this page where the file is available, and it is the reference for every value shown here. To order, send the RFQ with part number SI5004 and the quantity required, together with the delivery location and any application details. Our team will confirm availability and respond with a quotation.

Datasheets & Documents
  • PDF Datasheet ifm SI5004 Flow Transmitter, 4-20 mA Analogue Output, 300 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm SI5004 Flow Transmitter, 4-20 mA Analogue

Answers from our engineering team on installation, compatibility and integration.

01What is the ifm SI5004?
The ifm SI5004 is a flow transmitter with a 4-20 mA analogue output. The ifm SI5004 turns the flow monitor housing into a continuous flow transmitter for liquids.
02What supply and protection rating does the SI5004 have?
According to the manufacturer datasheet the SI5004 operates from 19...36 DC and has protection III.
03Is the SI5004 still available from the manufacturer?
The manufacturer datasheet does not carry a phase-out or archive notice, but availability changes over time, so ask us to confirm stock and lead time when you send the RFQ.
04Does Seven Star LLC supply the SI5004 in Oman?
Yes, Seven Star LLC quotes the SI5004 for projects and maintenance in Oman and the GCC. Send the part number SI5004 and the quantity and we will respond with availability.
05How do I get a quotation for the SI5004?
Use the RFQ form on this page with the part number SI5004, the quantity and your delivery location. We will reply with a quotation after checking availability.