Brand:

MTL MTL5575 Temperature Converter THC/RTD with Alarm Output

Description

MTL5575 overview

The MTL5575 converts a low-level signal from a thermocouple or RTD in the hazardous area into a 4/20 mA current and adds a single configurable alarm output. The alarm can serve as a process alarm or give early warning of thermocouple failure, which makes the module useful where the control system has limited alarm inputs.

The MTL5575 is part of the MTL5500 range of DIN-rail mounted intrinsically safe isolators from MTL, a brand of Eaton. As a single-channel module, it is a temperature converter with alarm that clips onto a standard 35 mm rail, with plug-in terminals for the hazardous-area and safe-area wiring. Because many MTL5500 numbers look alike, this page repeats the facts taken from the manufacturer datasheet so that engineers can confirm that the MTL5575 matches their loop before sending an enquiry.

Key features of the MTL MTL5575

  • Thermocouple types J, K, T, E, R, S, B, N and XK plus 2-, 3- and 4-wire RTDs
  • Single alarm relay output configurable as process alarm or early burnout alarm
  • Automatic or selectable cold-junction compensation
  • Configurable response time, 500 ms by default
  • PC configuration with PCS45 software
  • Fully galvanic isolation: 250 V rms between safe-area and hazardous-area terminals, and 250 V rms between safe-area circuits and the power supply
  • Powered from 20 to 35 V dc, with an optional Powerbus system to share the supply across a row of modules

MTL5575 technical specifications

Parameter Value
Model MTL5575
Range MTL5500 DIN-rail isolators
Supply voltage 20 to 35 V dc
Isolation 250 V rms tested at 1500 V rms minimum between safe and hazardous terminals; 250 V rms between safe-area circuits and supply
Terminals accept conductors up to 2.5 mm squared, stranded or single-core
Mounting 35 mm T-section DIN rail (7.5 or 15 mm) to EN 50022
Ambient temperature minus 20 to plus 60 C operating; minus 40 to plus 80 C storage
Humidity 5 to 95 percent relative humidity
Weight approximately 150 g
EMC to EN 61326 and NE21
Location of module safe area
Number of channels One
Millivolt input minus 75 to plus 75 mV, minimum span 3 to 150 mV
Resistance input 0 to 400 ohm (0 to 1000 ohm for Pt and Ni sensors)
RTD types Pt100, Pt500, Pt1000, Cu-50, Cu-53, Ni100, Ni500, Ni1000 (2-, 3- or 4-wire)
RTD excitation current 200 microamps nominal
CJC error 1.0 C or less
Output range 4 to 20 mA nominal into 600 ohm maximum
Alarm output relay on in alarm, 250 mA at 35 V maximum
Early burnout alarm trips when loop resistance increases by more than 50 ohm
Response time configurable, 500 ms default
Accuracy at 20 C, mV/THC plus or minus 15 microvolts or 0.05 percent of input, whichever is greater
Supply current 50 mA at 24 V with 20 mA signal
Power dissipation 1.2 W at 24 V

The module must be installed in the safe area, while the field device it serves may be located as the datasheet allows: Zone 0, IIC, T4 to T6 hazardous area where the connected device is suitably certified, or a Division 1, Group A hazardous location. Always read the current approval certificate on the manufacturer website for entity parameters, since the datasheet states that safety approvals can be revised.

Typical applications of the MTL5575 in Oman and the GCC

The manufacturer describes the MTL5575 as a configurable temperature converter for thermocouples and RTDs with an alarm output. In Gulf plants this duty usually means temperature loops that need a local or system alarm contact in addition to the 4/20 mA signal, for example heater trip or high-temperature alarm duty.

  • Oil and gas: wellsites, gathering stations, gas plants and pipeline terminals
  • Utilities and power: turbine skids, fuel gas systems and boiler auxiliaries
  • Water and desalination: chemical dosing, treatment and pumping areas with flammable vapour risk
  • Petrochemical and manufacturing: solvent storage, loading bays and process units

Many older Gulf installations carry MTL5000 or MTL4000 series isolators. The datasheet states that the MTL5500 can replace MTL5000 units, so the MTL5575 is often requested as a like-for-like spare during shutdowns.

Selection and compatibility notes for the MTL5575

The alarm relay switches up to 250 mA at 35 V, so use an interposing relay for larger loads. Set the safety drive for sensor failure, upscale, downscale or off, to match the control-system philosophy.

Check the certificate of the field device against the safety description of the MTL5575: the field device must tolerate the module output parameters, and the cable capacitance and inductance must stay within the permitted limits. The maximum safe-area voltage Um for the range is 253 V rms or dc.

Installation and commissioning of the MTL5575

Clip the module onto the DIN rail and fit the supplied connectors. The hazardous-area plugs are the blue-labelled terminals, and the safe-area plugs and the power connector are separate parts. When crimp ferrules are used, the manufacturer recommends a metal tube length of 12 mm and a wire trim length of 14 mm. Keep intrinsically safe wiring segregated from other wiring as required by the installation code, and record the loop tag on the optional TH5000 tag holder. Check the supply is within 20 to 35 V dc before energising, and verify the loop with the module fitted before connecting the field cable.

Maintenance and spare parts

An isolator has no user-serviceable parts. Routine checks are limited to terminal tightness, LED status, supply voltage and a periodic loop test according to the plant procedure. A failed module should be replaced as a whole, and the plug-in connectors can be moved to the replacement. Related accessories listed in the datasheet include the HAZ and SAF connector plugs, the PWR5000 power connector, the PB-8T, PB-16T, PB-24T and PB-32T Powerbus kits and the THR2 rail.

Related products and ordering notes for the MTL5575

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The MTL5500 range is the DIN-rail version of the family and the MTL4500 range is the backplane-mounted version, so quote the exact number MTL5575 when ordering, and mention any suffix, because a letter such as S, A, B, C, D or Y changes the function.

MTL5575 FAQ summary

Typical questions concern the function, the safety description and the supply of the MTL5575. It is a configurable temperature converter for thermocouples and RTDs with an alarm output, powered from 20 to 35 V dc, with the figures listed in the table above.

Documents and quotation

The range datasheet for the MTL5575 is attached to this page. To request a quotation, send an RFQ with the part number MTL5575, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.

Other Models in the MTL5500 Range

Seven Star LLC supplies models from the MTL5500 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MTL MTL5544 2-Channel HART Repeater Power SupplyIsolator & BarrierView details
MTL MTL5546 4-20 mA HART Isolating Driver with LFDIsolator & BarrierView details
MTL MTL5501-SR Fail-Safe Switch Interface with LFD, SIL3Isolator & BarrierView details
MTL MTL5510 4-Channel Switch/Proximity Interface, Solid-StateIsolator & BarrierView details
MTL MTL5511 1-Channel Switch/Proximity Interface, Relay + LFDIsolator & BarrierView details
MTL MTL5513 2-Channel Switch/Proximity Interface, Solid-StateIsolator & BarrierView details
MTL MTL5514 1-Channel Switch/Proximity Interface, LFD RelayIsolator & BarrierView details
MTL MTL5516C 2-Channel Switch/Proximity Interface, Relay + LFDIsolator & BarrierView details
MTL MTL5517 2-Channel Switch/Proximity Interface, NO RelaysIsolator & BarrierView details
MTL MTL5521 Loop-Powered Solenoid/Alarm Driver, IICIsolator & BarrierView details
MTL MTL5523 Solenoid/Alarm Driver with Line Fault DetectionIsolator & BarrierView details
MTL MTL5525 Low-Power Solenoid/Alarm Driver, SIL3, IICIsolator & BarrierView details
MTL MTL5531 Vibration Transducer Interface, 2/3-WireIsolator & BarrierView details
MTL MTL5532 Pulse Isolator, Digital or 4-20 mA OutputIsolator & BarrierView details
MTL MTL5561 2-Channel Fire/Smoke Detector InterfaceIsolator & BarrierView details
MTL MTL5573 Temperature Converter for THC/RTD, 4-20 mAIsolator & BarrierView details
MTL MTL5575 Temperature Converter THC/RTD with Alarm OutputIsolator & BarrierYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL MTL5575 Temperature Converter THC/RTD with

Answers from our engineering team on installation, compatibility and integration.

01What is the MTL5575 used for?
The datasheet describes the MTL5575 as a configurable temperature converter for thermocouples and RTDs with an alarm output.
02What supply does the MTL5575 need?
It is powered from 20 to 35 V dc and is installed in the safe area, with 250 V rms isolation between the safe-area circuits and the supply.
03How is the MTL5575 mounted?
It clips onto a 35 mm T-section DIN rail and uses plug-in terminals that accept conductors up to 2.5 mm squared.
04Can the MTL5575 replace an older MTL5000 module?
The manufacturer states that the MTL5500 range can replace MTL5000 units, but check the function, suffix and certificate before ordering.
05How do I request a quotation for the MTL5575?
Send an RFQ with the part number MTL5575, quantity and delivery location in Oman or the GCC, and we will reply with availability and lead time.