- Automation & ControlView all 2,859 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Panametrics
Panametrics VeriDri Loop-Powered Moisture Transmitter
Description
Panametrics VeriDri overview
The Panametrics VeriDri is a compact, loop-powered moisture transmitter that outputs dew point temperature or PPMv moisture as a 4 to 20 mA signal. It is aimed at OEM applications such as regenerative desiccant air and gas dryers, plastic drying, medical air dryers and glove box monitoring. Inside is a thin-film aluminum oxide moisture sensor combined with microprocessor-based digital electronics.
For buyers in Oman and the wider Gulf, the VeriDri is a part that is searched for by exact model name, because the equipment it belongs to often stays in service for many years. This page describes the VeriDri moisture transmitter using only information published by the manufacturer, so that you can confirm the model before you send a request for quotation. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the Panametrics VeriDri
The manufacturer highlights the following points for the VeriDri.
- Loop-powered 4 to 20 mA output, 7 to 28 VDC supply.
- Overall range capability -110 to 20 C (-130 to 70 F) dew point, or 0 to 10,000 PPMv at constant pressure.
- Thin-film aluminum oxide sensor with NIST-traceable calibration.
- Type 4X / IP67 enclosure and compact size.
- Meets specified accuracy within three minutes of warm-up.
- Can be installed in the process stream or in a sample system.
- Enables on-demand regeneration of dryers rather than timed cycles.
Together these points explain why the VeriDri remains a practical choice where the measurement must be dependable and where service access is limited. Each statement above comes from the published datasheet, and nothing has been added beyond it.
Technical specifications of the VeriDri
| Parameter | Value |
|---|---|
| Output | 4 to 20 mA, resolution 0.01 mA |
| Power | 7 to 28 VDC loop-powered |
| Maximum loop resistance | 50 x (supply voltage minus 7) ohms, for example 850 ohms at 24 VDC |
| Dew point ranges (examples) | -110 to 20 C; -80 to 20 C; -30 to 20 C; -100 to 0 F; -40 to 70 F |
| PPMv ranges | 0-10, 0-100, 0-1000, 0-10,000 PPMv at constant pressure |
| Accuracy | 2 C above -100 C; 3 C below -100 C |
| Repeatability | 0.2 C above -100 C; 0.5 C below -100 C |
| Operating temperature | -40 to 60 C (-40 to 140 F) |
| Operating pressure | 5 micron Hg to 5000 psig (345 bar) |
| Process connection | 3/4 in.-16 straight male thread with O-ring; G 1/2 in. with optional adapter |
| Enclosure | Type 4X, IP67 |
| Dimensions | 6.76 in. x 1.13 in. diameter (172 mm x 29 mm) |
| Weight | 5 oz (140 g) |
| Cable | 6 ft (2 m) standard |
| Recalibration | Every six to 12 months recommended |
Values are taken from the manufacturer datasheet for the VeriDri; always confirm against the current document, because ranges, certifications and options depend on the exact configuration that is ordered.
Typical applications for the VeriDri in Oman and the GCC
The VeriDri is applied in desiccant dryers for instrument air, plant air and gas, plastic resin drying, medical air systems and glove boxes at industrial sites in Oman and the GCC.
In oil and gas, the VeriDri supports process monitoring where an accurate reading helps operators protect equipment and keep production stable. In utilities and water, it gives plant teams a measurement they can trust for balance and efficiency checks. In general manufacturing, it is used wherever the process fluid or gas has to be controlled closely. The hot climate and demanding duty of the region put extra weight on dependable instruments, so spare availability of the VeriDri matters to maintenance planners.
Selection and compatibility notes for the VeriDri
The output range is factory configured, so the chosen dew point or PPMv range must be stated at ordering. For PPMv ranges the operating pressure must also be supplied because the range is based on constant pressure. A loop power supply, within the resistance limit, is the only electrical requirement. Sensor recalibration by the manufacturer is recommended every six to 12 months depending on application.
If you are replacing an existing VeriDri, the safest approach is to read the nameplate, note the full model code, serial number and any certification marking, and send those details with your enquiry. This avoids mismatches in mounting, connector or range, which are the most common causes of a replacement that does not fit.
Installation and commissioning of the VeriDri
Follow the installation guide or user manual that belongs to your meter or analyzer. Before fitting the VeriDri, check that the process conditions, including temperature, pressure and fluid, are inside the limits in the specification table. Confirm the cable or connector type, use the recommended wiring and keep signal cables away from power cabling. After mounting, verify the reading against a known reference or an expected process value and record the configuration so that later maintenance can repeat it. In hazardous areas, install only with the certified accessories and follow the local code of practice.
Maintenance and service life of the VeriDri
Routine care for the VeriDri consists of visual inspection of the connector, cable, seals and mounting hardware, checking the reading for drift or noise, and keeping the surface free of deposits where that applies to the design. Keep a spare on the shelf for critical measurements, since lead times for specialist parts can be long. Recalibration or exchange intervals should follow the manufacturer recommendation for the instrument system in which the VeriDri operates.
Related products and ordering notes for the VeriDri
The VeriDri is one member of the wider Panametrics range of flow, moisture, oxygen and gas measurement equipment. Related items on this site include other Panametrics analyzers and flow meters. When ordering, give the exact part or model code, the quantity, the meter or analyzer it will connect to and the delivery location. Do not rely on the family name alone, because the VeriDri family has several configurations.
Frequently asked questions about the VeriDri
The questions below summarize what buyers most often ask about the Panametrics VeriDri: what it is, where it is used, which conditions it handles and how to order a matching part. The answers are drawn from the published datasheet. For anything that depends on a specific configuration, send us the nameplate data and we will help confirm the match before quoting.
Documents and quotation
A manufacturer datasheet for the VeriDri is attached to this page. To request a quotation, send the RFQ with the part number VeriDri, the full model code from your nameplate and the quantity you need, and our team will respond with availability and lead time. VeriDri enquiries from Oman and the GCC are welcome.
Datasheets & Documents
- Datasheet Panametrics VeriDri Loop-Powered Moisture Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics VeriDri Loop-Powered Moisture
Answers from our engineering team on installation, compatibility and integration.
01What is the Panametrics VeriDri?
The Panametrics VeriDri is a loop-powered dew point and PPMv moisture transmitter. It is described in the manufacturer datasheet referenced on this page.
02Where is the VeriDri typically used?
The datasheet and application notes point to uses such as desiccant dryers for instrument air and similar process duties.
03What are the key specifications of the VeriDri?
Output: 4 to 20 mA, resolution 0.01 mA; Power: 7 to 28 VDC loop-powered. See the specifications table for the full list.
04How do I make sure I order the correct VeriDri?
Send the full model code, nameplate details and the instrument it connects to. Many Panametrics items are configured by code, so every field must match.
05Is Seven Star LLC affiliated with the manufacturer of the VeriDri?
No. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number and quantity.


















Reviews
There are no reviews yet.