Brand:

Pedrollo TURBO Twin-Impeller Centrifugal Pump

Description

Pedrollo TURBO pump explained

The Pedrollo TURBO is a twin-impeller centrifugal pump for clean water, rated up to 200 l/min (12 m³/h), up to 68 m of head and 10 bar, with cast iron inlet and outlet parts and stainless steel impellers. Seven Star LLC supplies the TURBO in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The code has a size number (4 or 6) and a letter (A, B or C) for impeller trim. The datasheet lists TURBO 4B at 1.1 kW (53 m), TURBO 4A at 1.5 kW (66 m), TURBO 6C at 1.1 kW (48 m), TURBO 6B at 1.5 kW (58 m) and TURBO 6A at 2.2 kW (68 m). TURBOm means single-phase.

TURBO technical specifications

Parameter Specification
Manufacturer / part number Pedrollo / TURBO
Flow rate up to 200 l/min (12 m³/h)
Head up up to 68 m
Manometric suction head up to 7 m
Liquid temperature between -10 °C and +90 °C
Ambient temperature between -10 °C and +40 °C
Maximum working pressure 10 bar
Motor 2 poles
Ingress protection rating IP X4
Inlet part Cast iron
Outlet part Cast iron
Impellers Stainless steel AISI 304
Shaft Stainless steel AISI 431

The values above come from the manufacturer technical data for the series. Individual models inside the TURBO range differ in power, head and current, so always confirm the exact model code before ordering.

How the TURBO works and what limits it

Two stainless steel AISI 304 impellers in series give a head between that of a single-impeller pump and a full multistage pump. Limits are suction up to 7 m, liquid -10 to +90 °C, ambient -10 to +40 °C, 10 bar and IP X4, with an AISI 431 shaft.

In a multistage centrifugal pump the liquid passes through several impellers in series, each stage adding head to the stage before it. The number of stages therefore sets the head, while the impeller width and motor power set the flow. The stage count is part of the model code, so a longer code number means a higher head at the same pipe size. Stable pressure, quiet running and a compact footprint are the practical benefits compared with a single-stage pump of the same head, and the pump gives its best efficiency when operated close to the middle of its curve.

TURBO models and performance data

Model Rated power P2 Head at first table point (50 Hz)
TURBOm 4B / TURBO 4B 1.1 kW / 1.5 HP 53 m
TURBOm 4A / TURBO 4A 1.5 kW / 2 HP 66 m
TURBOm 6C / TURBO 6C 1.1 kW / 1.5 HP 48 m
TURBOm 6B / TURBO 6B 1.5 kW / 2 HP 58 m
TURBOm 6A / TURBO 6A 2.2 kW / 3 HP 68 m

The heads in this table are read from the first point of the manufacturer 50 Hz performance table and fall as flow increases, so use the full curve for the real duty point. Where a 60 Hz version is needed, ask us: the manufacturer states that 60 Hz motors are available on request for many models.

Where the TURBO fits: related Pedrollo pumps

Single-stage alternatives are the CP and 2CP; for more stages see the MK and HT-PRO.

Selecting a TURBO pump: checklist

  • Choose size 4 for lower flow or 6 for up to 200 l/min
  • Choose A, B or C for head
  • Verify 10 bar, 90 °C
  • Single-phase TURBOm or three-phase TURBO
  • Fit with a pressure tank if used as a booster

Installing and maintaining the TURBO

Place the pump on a level, rigid base and tighten the anchor bolts evenly so the pump body is not stressed by the piping. Support the suction and delivery pipes independently, fit isolating valves on both sides to allow servicing, and add a non-return valve on the delivery side. Prime the pump fully before starting, because the stages must be filled with liquid to avoid running dry. Check the motor rotation on three-phase units, fit overload protection matched to the nameplate current, and make sure the pump never runs against a closed delivery for more than a short time. For pressure boosting, size the tank and pressure switch (or use a variable-speed controller) so that the number of starts per hour stays within the motor limit.

TURBO applications in Oman and the GCC

The manufacturer recommends booster sets and storage tanks, mains pressure boosting and irrigation. In the GCC it suits compact boosting for buildings, workshops and farms where a stainless impeller is wanted at moderate cost. Keep the water clean and cool in summer by shading pipework.

In hotels, hospital blocks and industrial sites around Muscat, Sohar and Salalah, multistage pumps run for long hours at steady pressure. Rooftop tanks can warm the water significantly, so check the temperature limit, and keep plant rooms ventilated. Chlorinated or desalinated supply water is normally acceptable only if the wetted material suits it, so state the water source on your enquiry.

Information to send with your TURBO RFQ

  • Duty point: flow rate and required discharge pressure or head
  • Suction conditions: flooded or lift, available NPSH and pipe size
  • Liquid, maximum temperature and presence of chlorine or solids
  • Supply: phase, voltage and frequency, and the starting method
  • Quantity and whether a pressure tank, switch, controller or spare seal is requested

Storage, handling and spares for the Pedrollo TURBO

Store the Pedrollo TURBO in a dry, covered place and keep it in its packaging until installation. If the pump is stored for a long time, turn the shaft by hand from time to time where the design allows it, so that seals do not stick. In Oman and the GCC, protect the motor and cable from direct sun and sand before installation.

  • Check the pump nameplate against the duty point and the power supply before installation.
  • Flush the pipework before connecting the pump, so that welding debris or sand does not enter the hydraulic parts.
  • Never run the pump dry; fit level control or dry-running protection where the application needs it.
  • Keep a spare mechanical seal kit and, for submersible models, a spare cable joint kit for planned maintenance.

When you send an RFQ for the Pedrollo TURBO, state the flow, head, liquid and power supply. With this information the right model and any spare parts can be confirmed together.

Documents and quotation

The manufacturer datasheet for the TURBO is attached on this page, and the performance tables in it should be checked against your duty point. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Send the model code, quantity, voltage and frequency and the duty point, and we will confirm availability and prepare a quotation for Oman and the GCC.

Other Models in the Pedrollo Multi Range

Seven Star LLC supplies models from the Pedrollo Multi range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pedrollo FCR 15-30 Horizontal Stainless Multistage PumpCentrifugal PumpsView details
Pedrollo MK Vertical Multistage Pump 0.75-2.2 kWCentrifugal PumpsView details
Pedrollo HT-PRO Vertical Stainless Multistage PumpCentrifugal PumpsView details
Pedrollo TURBO Twin-Impeller Centrifugal PumpCentrifugal PumpsYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pedrollo is an Italian manufacturer of electric pumps, founded in 1974 by Silvano Pedrollo and headquartered in San Bonifacio, near Verona, where its plant covers more than 150,000 square metres. The company exports to over 160 countries through ten commercial branches, starting with Pedrollo France in 1987. Its pumps are used for domestic water supply, irrigation, boreholes, pressure boosting and drainage.

Seven Star LLC is an independent supplier in Muscat. We list Pedrollo pumps for homes, farms and contractors in Oman and the GCC.

Pedrollo company profile

Founded 1974, by Silvano Pedrollo
Headquarters San Bonifacio, Verona, Italy
Ownership Pedrollo family
Reach Exports to over 160 countries through ten commercial branches
Product families PKm peripheral pumps, CP and F centrifugal pumps, JSWm self-priming jet pumps, 4SR and 6SR submersible borehole pumps, TOP and VXm drainage pumps, HF high-flow pumps, pressure booster sets

Milestones

  • 1974: Silvano Pedrollo founds the company.
  • 1987: Pedrollo France, the first foreign branch, opens.
  • 2009: Pedrollo acquires a majority stake in Saci Pumps.

Pedrollo product series

Surface pumps include the CP close-coupled centrifugal pump from 0.25 to 2.2 kW, the 2CP twin-impeller pump from 1.1 to 11 kW, the F EN 733 close-coupled pump, the NGA open-impeller pump for dirty water and the HT vertical multistage pump.

Submersible pumps include the 4SR and 6SR borehole pumps for 4 and 6 inch wells and the VX vortex sewage pump.

Close-coupled centrifugal pumps suit clean water transfer and boosting, twin-impeller 2CP pumps give higher head at moderate flow, and the open-impeller NGA handles water with some solids. Submersible 4SR and 6SR pumps are matched to the well diameter, flow and depth, and the VX vortex pump passes solids in sewage and drainage.

Where Pedrollo pumps are used

Water supply and pressure boosting, irrigation, wells, tank transfer, and drainage and sewage.

Pedrollo products we list

Family Examples
Pumps 2CP Twin-Impeller Centrifugal Pump 1.1-1…, 4SR 4-Inch Submersible Borehole Pump, 6SR 6-Inch Submersible Borehole Pump, CP Close-Coupled Centrifugal Pump 0.25-2…, F EN 733 Close-Coupled Centrifugal Pump, HT Vertical Multistage Centrifugal Pump, NGA Open-Impeller Centrifugal Pump for D…

Ordering Pedrollo pumps: what we need

Send the model or the flow, head and liquid, the power supply and the well diameter or installation type.

Facts checked against Pedrollo's own history page (pedrollo.com), October 2026.

FAQ

Questions about the Pedrollo TURBO Twin-Impeller Centrifugal Pump

Answers from our engineering team on installation, compatibility and integration.

01How many impellers does the TURBO have?
It has two impellers in series, which gives a higher head than a single-impeller design of the same size.
02What is the maximum flow of the TURBO?
The size 6 models reach up to 200 l/min (12 m³/h), and the head goes up to 68 m.
03Can the TURBO run against a closed valve?
Only for very short periods, because the liquid heats up and the seal and stages can be damaged.
04Does the stage count matter on the TURBO?
Yes. Each stage adds head, so the stage number in the model code sets the pressure the pump can build.
05Is a pressure tank required with the TURBO?
For domestic boosting a tank and pressure switch reduce the number of starts, unless a variable-speed controller is used.