Pedrollo FCR 15-30 pump explained

The Pedrollo FCR 15-30 is a family of horizontal multistage centrifugal pumps made of stainless steel AISI 304, rated up to 800 l/min (48 m³/h) and up to 120 m of head, with a 12 bar working-pressure limit. It includes the FCR 15, FCR 22 and FCR 30 sizes, each with several stage counts. Seven Star LLC supplies the FCR in Oman and the GCC as an independent supplier in Muscat.

In a code such as FCR 22/4, the 22 is the hydraulic size (nominal flow class) and the 4 is the number of stages. Some codes carry an R after the stage count (FCR 15/2R, FCR 15/3R, FCR 30/2R), which the datasheet lists as separate models with their own motor power, so quote the full code. The datasheet lists FCR 15/2R at 2.2 kW with 44 m, FCR 15/5 at 7.5 kW with 120 m, FCR 22/2 at 3 kW with 39 m, FCR 22/5 at 7.5 kW with 98 m and FCR 30/4 at 7.5 kW with 80 m.

FCR 15-30 technical specifications

Parameter Specification
Manufacturer / part number Pedrollo / FCR 15-30
Flow rate up to 800 l/min (48 m³/h)
Head up up to 120 m
Manometric suction head up to 7 m
Liquid temperature between -15 °C and +90 °C
Ambient temperature up to +40 °C
Maximum working pressure 12 bar
Motor 2 poles
Ingress protection rating IP 55
Pump housing Stainless steel AISI 304
Impellers Stainless steel AISI 304
Diffusers Stainless steel AISI 304
Shaft Stainless steel AISI 431
Pump cover Stainless steel AISI 304

The values above come from the manufacturer technical data for the series. Individual models inside the FCR 15-30 range differ in power, head and current, so always confirm the exact model code before ordering.

How the FCR 15-30 works and what limits it

All wetted parts, including pump housing, impellers, diffusers and cover, are stainless steel AISI 304, the shaft is AISI 431 and the motors are three-phase IE3 with IP 55 protection. Operating limits are suction up to 7 m, liquid -15 to +90 °C, ambient up to +40 °C and 12 bar. The manufacturer notes silent operation and energy efficiency as the main advantages.

In a multistage centrifugal pump the liquid passes through several impellers in series, each stage adding head to the stage before it. The number of stages therefore sets the head, while the impeller width and motor power set the flow. The stage count is part of the model code, so a longer code number means a higher head at the same pipe size. Stable pressure, quiet running and a compact footprint are the practical benefits compared with a single-stage pump of the same head, and the pump gives its best efficiency when operated close to the middle of its curve.

FCR 15-30 models and performance data

Model Rated power P2 Head at first table point (50 Hz)
FCR 15/2R 2.2 kW / 3 HP 44 m
FCR 15/3 4 kW / 5.5 HP 72 m
FCR 15/5 7.5 kW / 10 HP 120 m
FCR 22/2 3 kW / 4 HP 39 m
FCR 22/5 7.5 kW / 10 HP 98 m
FCR 30/2 4 kW / 5.5 HP 40 m
FCR 30/4 7.5 kW / 10 HP 80 m

The heads in this table are read from the first point of the manufacturer 50 Hz performance table and fall as flow increases, so use the full curve for the real duty point. Where a 60 Hz version is needed, ask us: the manufacturer states that 60 Hz motors are available on request for many models.

Where the FCR 15-30 fits: related Pedrollo pumps

Compare with the vertical HT-PRO, which has similar stainless construction and reaches 160 m, and the MK vertical pumps for smaller domestic duty. The VSP builds an FCR hydraulic into a variable-speed unit.

Selecting a FCR 15-30 pump: checklist

  • Select size 15, 22 or 30 from the flow
  • Select the stage count from the head needed
  • Check the 12 bar working-pressure limit against the shutoff head plus inlet pressure
  • Confirm the liquid temperature between -15 and +90 °C
  • Three-phase supply required, IE3 motor

Installing and maintaining the FCR 15-30

Place the pump on a level, rigid base and tighten the anchor bolts evenly so the pump body is not stressed by the piping. Support the suction and delivery pipes independently, fit isolating valves on both sides to allow servicing, and add a non-return valve on the delivery side. Prime the pump fully before starting, because the stages must be filled with liquid to avoid running dry. Check the motor rotation on three-phase units, fit overload protection matched to the nameplate current, and make sure the pump never runs against a closed delivery for more than a short time. For pressure boosting, size the tank and pressure switch (or use a variable-speed controller) so that the number of starts per hour stays within the motor limit.

FCR 15-30 applications in Oman and the GCC

In Oman and the GCC the FCR can feed building boosting sets, industrial wash systems, irrigation systems with an autoclave tank and cooling or process water where stainless steel is preferred for its corrosion resistance. For hotel and commercial buildings, the horizontal layout fits in plant rooms with limited height.

In hotels, hospital blocks and industrial sites around Muscat, Sohar and Salalah, multistage pumps run for long hours at steady pressure. Rooftop tanks can warm the water significantly, so check the temperature limit, and keep plant rooms ventilated. Chlorinated or desalinated supply water is normally acceptable only if the wetted material suits it, so state the water source on your enquiry.

Information to send with your FCR 15-30 RFQ

  • Duty point: flow rate and required discharge pressure or head
  • Suction conditions: flooded or lift, available NPSH and pipe size
  • Liquid, maximum temperature and presence of chlorine or solids
  • Supply: phase, voltage and frequency, and the starting method
  • Quantity and whether a pressure tank, switch, controller or spare seal is requested

Documents and quotation

The manufacturer datasheet for the FCR 15-30 is attached on this page, and the performance tables in it should be checked against your duty point. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Send the model code, quantity, voltage and frequency and the duty point, and we will confirm availability and prepare a quotation for Oman and the GCC.

Other Models in the Pedrollo Multi Range

Seven Star LLC supplies models from the Pedrollo Multi range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pedrollo FCR 15-30 Horizontal Stainless Multistage PumpCentrifugal PumpsYou are viewing this model
Pedrollo MK Vertical Multistage Pump 0.75-2.2 kWCentrifugal PumpsView details
Pedrollo HT-PRO Vertical Stainless Multistage PumpCentrifugal PumpsView details
Datasheets & Documents
  • PDF Datasheet Pedrollo FCR 15-30 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pedrollo is an Italian manufacturer of electric pumps, founded in 1974 by Silvano Pedrollo and headquartered in San Bonifacio, near Verona, where its plant covers more than 150,000 square metres. The company exports to over 160 countries through ten commercial branches, starting with Pedrollo France in 1987. Its pumps are used for domestic water supply, irrigation, boreholes, pressure boosting and drainage.

Seven Star LLC is an independent supplier in Muscat. We list Pedrollo pumps for homes, farms and contractors in Oman and the GCC.

Pedrollo company profile

Founded 1974, by Silvano Pedrollo
Headquarters San Bonifacio, Verona, Italy
Ownership Pedrollo family
Reach Exports to over 160 countries through ten commercial branches
Product families PKm peripheral pumps, CP and F centrifugal pumps, JSWm self-priming jet pumps, 4SR and 6SR submersible borehole pumps, TOP and VXm drainage pumps, HF high-flow pumps, pressure booster sets

Milestones

  • 1974: Silvano Pedrollo founds the company.
  • 1987: Pedrollo France, the first foreign branch, opens.
  • 2009: Pedrollo acquires a majority stake in Saci Pumps.

Pedrollo product series

Surface pumps include the CP close-coupled centrifugal pump from 0.25 to 2.2 kW, the 2CP twin-impeller pump from 1.1 to 11 kW, the F EN 733 close-coupled pump, the NGA open-impeller pump for dirty water and the HT vertical multistage pump.

Submersible pumps include the 4SR and 6SR borehole pumps for 4 and 6 inch wells and the VX vortex sewage pump.

Close-coupled centrifugal pumps suit clean water transfer and boosting, twin-impeller 2CP pumps give higher head at moderate flow, and the open-impeller NGA handles water with some solids. Submersible 4SR and 6SR pumps are matched to the well diameter, flow and depth, and the VX vortex pump passes solids in sewage and drainage.

Where Pedrollo pumps are used

Water supply and pressure boosting, irrigation, wells, tank transfer, and drainage and sewage.

Pedrollo products we list

Family Examples
Pumps 2CP Twin-Impeller Centrifugal Pump 1.1-1…, 4SR 4-Inch Submersible Borehole Pump, 6SR 6-Inch Submersible Borehole Pump, CP Close-Coupled Centrifugal Pump 0.25-2…, F EN 733 Close-Coupled Centrifugal Pump, HT Vertical Multistage Centrifugal Pump, NGA Open-Impeller Centrifugal Pump for D…

Ordering Pedrollo pumps: what we need

Send the model or the flow, head and liquid, the power supply and the well diameter or installation type.

Facts checked against Pedrollo's own history page (pedrollo.com), October 2026.

FAQ

Questions about the Pedrollo FCR 15-30 Horizontal Stainless Multistage

Answers from our engineering team on installation, compatibility and integration.

01What is the pressure limit of the FCR 15-30?
The maximum working pressure is 12 bar. Add the inlet pressure to the pump shutoff head when checking this limit.
02What do the numbers in FCR 22/4 mean?
The 22 is the hydraulic size and the 4 is the number of stages. More stages give a higher head at the same flow class.
03Can the FCR 15-30 run against a closed valve?
Only for very short periods, because the liquid heats up and the seal and stages can be damaged.
04Does the stage count matter on the FCR 15-30?
Yes. Each stage adds head, so the stage number in the model code sets the pressure the pump can build.
05Is a pressure tank required with the FCR 15-30?
For domestic boosting a tank and pressure switch reduce the number of starts, unless a variable-speed controller is used.