Pedrollo HF Medium Flow Centrifugal Pump 0.37-2.2 kW
Description
Pedrollo HF Medium Flow pump explained
The Pedrollo HF Medium Flow is a range of single-impeller centrifugal pumps for large flows at medium to low heads, reaching up to 700 l/min (42 m³/h) and up to 39 m, with 0.37 to 2.2 kW motors. It has a cast iron body, a stainless steel AISI 304 impeller and shaft cover. Seven Star LLC supplies the HF in Oman and the GCC as an independent supplier in Muscat.
HF 50, HF 51, HF 70 and HF 5 are the four size lines. Letters A, B and C step through impeller sizes, and the datasheet lists the HF 5 line with extra suffixes (BM, AM, ARM) as separate models, so quote the full code. The datasheet lists HF 50B at 0.37 kW (10 m), HF 51A at 0.75 kW (21.2 m), HF 70A at 2.2 kW (39 m) and HF 5ARM at 2.2 kW (23.5 m). HFm is single-phase, and the HF 70A is listed in three-phase only.
HF Medium Flow technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pedrollo / HF Medium Flow |
| Flow rate | up to 700 l/min (42 m³/h) |
| Head up | up to 39 m |
| Manometric suction head | up to 7 m |
| Liquid temperature | between -10 °C and +90 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | – 6 bar for HF 5-50-51 – 10 bar for HF 5M-70 |
| Motor | 2 poles |
| Ingress protection rating | IP X4 |
| Pump housing | Cast iron |
| Impeller | Stainless steel AISI 304 |
| Shaft | Stainless steel AISI 431 |
| Pump cover | Stainless steel AISI 304 Cast iron (for HF 5M, HF 70) |
The values above come from the manufacturer technical data for the series. Individual models inside the HF Medium Flow range differ in power, head and current, so always confirm the exact model code before ordering.
How the HF Medium Flow works and what limits it
Working pressure is 6 bar for HF 5-50-51 and 10 bar for HF 5M and HF 70, suction up to 7 m, liquid -10 to +90 °C, ambient up to +40 °C and IP X4. The pump has a stainless steel AISI 304 impeller, a cover in AISI 304 (cast iron for HF 5M and HF 70) and an AISI 431 shaft.
EN 733 defines the dimensions and rated duty points of end-suction centrifugal pumps on a bearing frame or close-coupled to a standard motor, with PN10 flanged ports. Because the port sizes, the shaft ends and the performance points are standardised, a pump of this kind can be matched to the dimensions of an existing installation and pumps from different makers share the same footprint logic. Liquid enters axially through the suction port, the impeller adds velocity, and the volute converts that velocity into pressure at the delivery flange. Efficiency is highest near the design point of the chosen impeller diameter.
HF Medium Flow models and performance data
| Model | Rated power P2 | Head at first table point (50 Hz) |
|---|---|---|
| HFm 50B / HF 50B | 0.37 kW / 0.50 HP | 10 m |
| HFm 51A / HF 51A | 0.75 kW / 1 HP | 21.2 m |
| HFm 70C / HF 70C | 1.1 kW / 1.5 HP | 29 m |
| HF 70A | 2.2 kW / 3 HP | 39 m |
| HFm 5A / HF 5A | 0.90 kW / 1.25 HP | 16 m |
| HFm 5ARM / HF 5ARM | 2.2 kW / 3 HP | 23.5 m |
The heads in this table are read from the first point of the manufacturer 50 Hz performance table and fall as flow increases, so use the full curve for the real duty point. Where a 60 Hz version is needed, ask us: the manufacturer states that 60 Hz motors are available on request for many models.
Where the HF Medium Flow fits: related Pedrollo pumps
For higher head see the CP and 2CP, for stainless steel see the F-INOX, and for a similar flow with an open impeller see the NGA-PRO.
Selecting a HF Medium Flow pump: checklist
- Choose by flow first: HF is a high-flow, low-head design
- Read the head from the table for each letter
- Check 6 bar (HF 5-50-51) or 10 bar (HF 5M, HF 70) limit
- Single-phase HFm or three-phase HF
- Check the suction path to keep the 7 m limit
Installing and maintaining the HF Medium Flow
Install the pump on a rigid baseplate or concrete plinth with the motor and pump shafts aligned within the limits given in the manual, and use flexible joints or expansion pieces if pipe forces could load the flanges. Keep the suction line straight for several pipe diameters before the pump, with a reducer that does not trap air, and avoid a suction pipe smaller than the port. Fill and vent the casing before starting, check the rotation, and never run the pump against a closed valve for long. Inspect the mechanical seal after the first weeks of service and at regular intervals. Keep a record of the nameplate data, since impeller trim and motor size change with the letter at the end of the model name.
HF Medium Flow applications in Oman and the GCC
The manufacturer lists furrow and sprinkler irrigation, drawing water from lakes, rivers and wells, and industrial applications with large flows and low pressure. In the GCC farms and landscaping projects use this class for tank-to-field transfer, and cooling-water circuits use it where head is low.
On industrial and municipal sites in Oman, standardised pumps are chosen because they can replace or match existing units on the same baseplate and flange pattern. Dust, high ambient temperature and coastal humidity are the usual design conditions, so verify motor protection class and specify a seal suitable for the liquid. State if the liquid is treated water, brackish water or cooling-tower make-up.
Information to send with your HF Medium Flow RFQ
- Duty point: flow rate and total head, plus the margin you want above it
- Liquid, temperature and any chlorides or other chemicals
- Suction conditions and NPSH available, pipe sizes and flange standard
- Motor requirement: voltage, frequency, IE class, and any bare-shaft or coupled arrangement
- Quantity, spares (mechanical seal, impeller) and delivery location
Documents and quotation
The manufacturer datasheet for the HF Medium Flow is attached on this page, and the performance tables in it should be checked against your duty point. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Send the model code, quantity, voltage and frequency and the duty point, and we will confirm availability and prepare a quotation for Oman and the GCC.
Other Models in the Pedrollo En733 Range
Seven Star LLC supplies models from the Pedrollo En733 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pedrollo F-INOX Stainless Steel EN 733 Pump | Centrifugal Pumps | View details |
| Pedrollo FG EN 733 Bare-Shaft Centrifugal Pump | Centrifugal Pumps | View details |
| Pedrollo HF Medium Flow Centrifugal Pump 0.37-2.2 kW | Centrifugal Pumps | You are viewing this model |
| Pedrollo NGA-PRO Stainless Open-Impeller Pump | Centrifugal Pumps | View details |
Datasheets & Documents
- Datasheet Pedrollo HF Medium Flow Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pedrollo is an Italian manufacturer of electric pumps, founded in 1974 by Silvano Pedrollo and headquartered in San Bonifacio, near Verona, where its plant covers more than 150,000 square metres. The company exports to over 160 countries through ten commercial branches, starting with Pedrollo France in 1987. Its pumps are used for domestic water supply, irrigation, boreholes, pressure boosting and drainage.
Seven Star LLC is an independent supplier in Muscat. We list Pedrollo pumps for homes, farms and contractors in Oman and the GCC.
Pedrollo company profile
| Founded | 1974, by Silvano Pedrollo |
|---|---|
| Headquarters | San Bonifacio, Verona, Italy |
| Ownership | Pedrollo family |
| Reach | Exports to over 160 countries through ten commercial branches |
| Product families | PKm peripheral pumps, CP and F centrifugal pumps, JSWm self-priming jet pumps, 4SR and 6SR submersible borehole pumps, TOP and VXm drainage pumps, HF high-flow pumps, pressure booster sets |
Milestones
- 1974: Silvano Pedrollo founds the company.
- 1987: Pedrollo France, the first foreign branch, opens.
- 2009: Pedrollo acquires a majority stake in Saci Pumps.
Pedrollo product series
Surface pumps include the CP close-coupled centrifugal pump from 0.25 to 2.2 kW, the 2CP twin-impeller pump from 1.1 to 11 kW, the F EN 733 close-coupled pump, the NGA open-impeller pump for dirty water and the HT vertical multistage pump.
Submersible pumps include the 4SR and 6SR borehole pumps for 4 and 6 inch wells and the VX vortex sewage pump.
Close-coupled centrifugal pumps suit clean water transfer and boosting, twin-impeller 2CP pumps give higher head at moderate flow, and the open-impeller NGA handles water with some solids. Submersible 4SR and 6SR pumps are matched to the well diameter, flow and depth, and the VX vortex pump passes solids in sewage and drainage.
Where Pedrollo pumps are used
Water supply and pressure boosting, irrigation, wells, tank transfer, and drainage and sewage.
Pedrollo products we list
Ordering Pedrollo pumps: what we need
Send the model or the flow, head and liquid, the power supply and the well diameter or installation type.
Facts checked against Pedrollo's own history page (pedrollo.com), October 2026.
Browse Pedrollo products by category: Pumps.
FAQ
Questions about the Pedrollo HF Medium Flow Centrifugal Pump 0.37-2.2 kW
Answers from our engineering team on installation, compatibility and integration.
01What kind of duty is the HF Medium Flow made for?
High flow at medium or low head, such as irrigation and drawing water from lakes, rivers and wells.
02What is the highest head in the HF range?
The HF 70A reaches 39 m at the first table point, with flow up to 700 l/min across the range.
03What does EN 733 mean for the HF Medium Flow?
It is the European standard that fixes the port sizes and rated duty points of end-suction centrifugal pumps, which helps when matching an existing installation.
04Can I replace the HF Medium Flow impeller to change duty?
The letter at the end of the model name indicates the impeller trim and motor size, so ask for the exact variant rather than trimming in the field.
05Does the HF Medium Flow need alignment?
Close-coupled and frame-mounted pumps both need correct shaft alignment and a rigid base for long seal life.