Brand: Pedrollo
Pedrollo MK Vertical Multistage Pump 0.75-2.2 kW
Description
Pedrollo MK pump explained
The Pedrollo MK is a series of compact, cost-effective vertical multistage centrifugal pumps rated up to 180 l/min (10.8 m³/h) and up to 114 m of head, with 11 bar working pressure. The inlet and outlet parts are cast iron and the impellers and diffusers are Noryl. Seven Star LLC supplies the MK in Oman and the GCC as an independent supplier in Muscat.
MK codes have two numbers separated by a slash, for example MK 5/7. The first number (3, 5 or 8) is the flow class and the second is the number of stages. MKm is the single-phase version and MK is the three-phase version. MK 3 runs from 3 to 6 stages and 0.75 to 1.5 kW, MK 5 from 4 to 8 stages and 0.75 to 2.2 kW, and MK 8 from 4 to 6 stages and 1.1 to 2.2 kW.
MK technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pedrollo / MK |
| Flow rate | up to 180 l/min (10.8 m³/h) |
| Head up | up to 114 m |
| Manometric suction head | up to 7 m |
| Liquid temperature | between -10 °C and +60 °C |
| Ambient temperature | up to +40 °C |
| Maximum working pressure | 11 bar |
| Motor | 2 poles |
| Ingress protection rating | IP X4 |
| Inlet part | Cast iron |
| Outlet part | Cast iron |
| Impellers | Noryl™ |
| Diffusers | Noryl™ |
| Shaft | Stainless steel AISI 431 |
The values above come from the manufacturer technical data for the series. Individual models inside the MK range differ in power, head and current, so always confirm the exact model code before ordering.
How the MK works and what limits it
The highest head listed is 114 m for the MK 5/8 and 105 m for the MK 3/6. Operating limits are suction up to 7 m, liquid -10 to +60 °C, ambient up to +40 °C and IP X4. Because the shaft is vertical, the footprint is small, and the AISI 431 shaft runs in a Noryl stage stack that is light and corrosion resistant.
In a multistage centrifugal pump the liquid passes through several impellers in series, each stage adding head to the stage before it. The number of stages therefore sets the head, while the impeller width and motor power set the flow. The stage count is part of the model code, so a longer code number means a higher head at the same pipe size. Stable pressure, quiet running and a compact footprint are the practical benefits compared with a single-stage pump of the same head, and the pump gives its best efficiency when operated close to the middle of its curve.
MK models and performance data
| Model | Rated power P2 | Head at first table point (50 Hz) |
|---|---|---|
| MKm 3/3 / MK 3/3 | 0.75 kW / 1 HP | 52.5 m |
| MKm 3/6 / MK 3/6 | 1.5 kW / 2 HP | 105 m |
| MKm 5/4 / MK 5/4 | 0.75 kW / 1 HP | 57 m |
| MKm 5/8 / MK 5/8 | 2.2 kW / 3 HP | 114 m |
| MKm 8/4 / MK 8/4 | 1.1 kW / 1.5 HP | 56 m |
| MKm 8/6 / MK 8/6 | 2.2 kW / 3 HP | 84 m |
The heads in this table are read from the first point of the manufacturer 50 Hz performance table and fall as flow increases, so use the full curve for the real duty point. Where a 60 Hz version is needed, ask us: the manufacturer states that 60 Hz motors are available on request for many models.
Where the MK fits: related Pedrollo pumps
For stainless steel construction at higher duty see the HT-PRO or the FCR 15-30. The VSP wraps MK hydraulics into a variable-speed unit (VSP-MK). Smaller jobs may use the PLURIJET or JSW.
Selecting a MK pump: checklist
- Choose flow class 3, 5 or 8 from the flow
- Choose the stage number from the head
- Check 11 bar working pressure and 60 °C liquid limit
- Single-phase MKm or three-phase MK
- Add a pressure tank and pressure switch for domestic boosting
Installing and maintaining the MK
Place the pump on a level, rigid base and tighten the anchor bolts evenly so the pump body is not stressed by the piping. Support the suction and delivery pipes independently, fit isolating valves on both sides to allow servicing, and add a non-return valve on the delivery side. Prime the pump fully before starting, because the stages must be filled with liquid to avoid running dry. Check the motor rotation on three-phase units, fit overload protection matched to the nameplate current, and make sure the pump never runs against a closed delivery for more than a short time. For pressure boosting, size the tank and pressure switch (or use a variable-speed controller) so that the number of starts per hour stays within the motor limit.
MK applications in Oman and the GCC
In the GCC the MK is typical for villa and small building boosting sets, garden irrigation and light commercial supply. Noryl stages are lighter and cheaper than stainless steel, so confirm the water does not contain sand and that the temperature stays below 60 °C, especially in rooftop tanks exposed to summer sun.
In hotels, hospital blocks and industrial sites around Muscat, Sohar and Salalah, multistage pumps run for long hours at steady pressure. Rooftop tanks can warm the water significantly, so check the temperature limit, and keep plant rooms ventilated. Chlorinated or desalinated supply water is normally acceptable only if the wetted material suits it, so state the water source on your enquiry.
Information to send with your MK RFQ
- Duty point: flow rate and required discharge pressure or head
- Suction conditions: flooded or lift, available NPSH and pipe size
- Liquid, maximum temperature and presence of chlorine or solids
- Supply: phase, voltage and frequency, and the starting method
- Quantity and whether a pressure tank, switch, controller or spare seal is requested
Documents and quotation
The manufacturer datasheet for the MK is attached on this page, and the performance tables in it should be checked against your duty point. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Send the model code, quantity, voltage and frequency and the duty point, and we will confirm availability and prepare a quotation for Oman and the GCC.
Other Models in the Pedrollo Multi Range
Seven Star LLC supplies models from the Pedrollo Multi range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pedrollo FCR 15-30 Horizontal Stainless Multistage Pump | Centrifugal Pumps | View details |
| Pedrollo MK Vertical Multistage Pump 0.75-2.2 kW | Centrifugal Pumps | You are viewing this model |
| Pedrollo HT-PRO Vertical Stainless Multistage Pump | Centrifugal Pumps | View details |
Datasheets & Documents
- Datasheet Pedrollo MK Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pedrollo is an Italian manufacturer of electric pumps, founded in 1974 by Silvano Pedrollo and headquartered in San Bonifacio, near Verona, where its plant covers more than 150,000 square metres. The company exports to over 160 countries through ten commercial branches, starting with Pedrollo France in 1987. Its pumps are used for domestic water supply, irrigation, boreholes, pressure boosting and drainage.
Seven Star LLC is an independent supplier in Muscat. We list Pedrollo pumps for homes, farms and contractors in Oman and the GCC.
Pedrollo company profile
| Founded | 1974, by Silvano Pedrollo |
|---|---|
| Headquarters | San Bonifacio, Verona, Italy |
| Ownership | Pedrollo family |
| Reach | Exports to over 160 countries through ten commercial branches |
| Product families | PKm peripheral pumps, CP and F centrifugal pumps, JSWm self-priming jet pumps, 4SR and 6SR submersible borehole pumps, TOP and VXm drainage pumps, HF high-flow pumps, pressure booster sets |
Milestones
- 1974: Silvano Pedrollo founds the company.
- 1987: Pedrollo France, the first foreign branch, opens.
- 2009: Pedrollo acquires a majority stake in Saci Pumps.
Pedrollo product series
Surface pumps include the CP close-coupled centrifugal pump from 0.25 to 2.2 kW, the 2CP twin-impeller pump from 1.1 to 11 kW, the F EN 733 close-coupled pump, the NGA open-impeller pump for dirty water and the HT vertical multistage pump.
Submersible pumps include the 4SR and 6SR borehole pumps for 4 and 6 inch wells and the VX vortex sewage pump.
Close-coupled centrifugal pumps suit clean water transfer and boosting, twin-impeller 2CP pumps give higher head at moderate flow, and the open-impeller NGA handles water with some solids. Submersible 4SR and 6SR pumps are matched to the well diameter, flow and depth, and the VX vortex pump passes solids in sewage and drainage.
Where Pedrollo pumps are used
Water supply and pressure boosting, irrigation, wells, tank transfer, and drainage and sewage.
Pedrollo products we list
Ordering Pedrollo pumps: what we need
Send the model or the flow, head and liquid, the power supply and the well diameter or installation type.
Facts checked against Pedrollo's own history page (pedrollo.com), October 2026.
Browse Pedrollo products by category: Pumps.
FAQ
Questions about the Pedrollo MK Vertical Multistage Pump 0.75-2.2 kW
Answers from our engineering team on installation, compatibility and integration.
01What do the numbers in MK 5/7 mean?
The 5 is the flow class and the 7 is the number of stages. The datasheet shows MK 5/7 at 1.5 kW and 99 m head at first point.
02Are MK stages made of stainless steel?
No. The impellers and diffusers are Noryl and the inlet and outlet parts are cast iron. The stainless steel option in the family is the HT-PRO.
03Can the MK run against a closed valve?
Only for very short periods, because the liquid heats up and the seal and stages can be damaged.
04Does the stage count matter on the MK?
Yes. Each stage adds head, so the stage number in the model code sets the pressure the pump can build.
05Is a pressure tank required with the MK?
For domestic boosting a tank and pressure switch reduce the number of starts, unless a variable-speed controller is used.