Brand:

Legrand 411161 DX3 2P 32 A C-Curve RCBO 30 mA AC

Description

411161: Legrand DX3 2-pole 32 A RCBO, C curve, 30 mA AC type

The Legrand 411161 is a DX3 6000 A two-pole residual current circuit breaker with overcurrent protection, rated 32 A with a C curve and 30 mA AC-type earth-leakage sensitivity. Both poles are protected, the device is 4 modules wide (71.2 mm) and it works on 230 V AC, 50 Hz. The catalogue lists 6 kA breaking capacity under EN 61009 and 10 kA under IEC 60947-2. Seven Star LLC supplies 411161 in Oman and the GCC as an independent supplier in Muscat.

Unlike the one-protected-pole 1P+N RCBOs that save a module, this two-pole device opens both the phase and the neutral conductor on overload or short circuit. That is a requirement in some installations and a design preference in others, and it affects the way the circuit is isolated for maintenance.

What the 411161 reference describes

Element Value Meaning
RCBO DX3 6000A Product Single-body residual current breaker with overcurrent trip
2 pole Two protected poles Phase and neutral both protected and switched
32 A, curve C Overcurrent Magnetic trip between 5 and 10 x In
30 mA type AC Residual AC residual currents, instantaneous trip
Ref. 411161 Catalogue number Quote on your enquiry

Technical specifications for 411161

Parameter Specification
Manufacturer / part number Legrand / 411161 (DX3 RCBO 6000 A, 2 pole, 32 A, C, 30 mA, type AC)
Poles 2 total, 2 protected, neutral switched concurrently
Rated current / curve 32 A / C
Rated residual current 30 mA, type AC
Rated voltage / frequency 230 V AC, 50 Hz; operating 170 to 253 V per data sheet
Breaking capacity Icn 6 kA (EN 61009-1); 10 kA under IEC 60947-2
Current limiting class 3
Surge current capacity 0.25 kA
Width / built-in depth 4 modular spacings (71.2 mm) / 44 mm
Conductors Solid-core 1–35 mm²; multi-wire 1–25 mm²
Protection / pollution IP20, pollution degree 2
Supply Copper cable (top or bottom) or prong busbar (top)
Mounting 35 mm DIN rail, two clamps, label holder, ON/OFF indication on the handle

How the 411161 works at 230 V

The thermal element reacts to sustained overload above 32 A, and the magnetic element trips on short circuits between 160 and 320 A, which is 5 to 10 times the rating. In parallel, a summation transformer senses the imbalance between phase and neutral. When the leakage reaches the 30 mA threshold, an electromagnetic relay opens the contacts of both poles. A test button on the front lets the installer check the residual function, and a yellow indicator shows a residual trip.

The two-pole body is 71.2 mm wide, four times the width of a basic one-module breaker,. This makes it a space-consuming choice in dense boards; if space is tight, a 1P+N RCBO such as 411053 or 411097, two modules wide, may be preferable.

Where 411161 fits and related parts

The 411161 protects a single-phase circuit such as a socket group, a water heater or an air-conditioner. The 4-pole siblings 411189 (32 A, 4 modules) and 411192 (63 A, 7 modules) cover three-phase circuits. Use the 2-pole version when the design needs both conductors switched or when local rules require double-pole disconnection of single-phase final circuits.

Selection checklist for 411161

  • Circuit current: 32 A with allowance for cable size and ambient temperature.
  • Disconnection: both phase and neutral open together.
  • Space: four modules, 71.2 mm; compare with 1P+N devices of 2 modules.
  • Type: AC suits resistive and lighting loads; use A or F for electronic loads.
  • Supply voltage: 230 V AC at 50 Hz.
  • Fault level: 6 kA under EN 61009, 10 kA under IEC 60947-2.

Installation, testing and maintenance of 411161

Clip the device on the rail and connect phase and neutral using the marked terminals, which accept 1 to 25 mm² flexible or 1 to 35 mm² rigid copper. Tighten to the recommended torque and apply the label. After energising, press the test button, which should open the circuit, then reset and record the date. A device that trips with the yellow indicator showing points to an earth fault; check insulation and appliances before resetting. Record 411161 in the circuit schedule and keep a spare for fast replacement.

Typical applications in Oman and the GCC

Single-phase final circuits in offices, accommodation blocks, workshops and site cabins use RCBOs for sockets and appliances. High ambient temperature and frequent use of air-conditioning loads are typical in Oman, so leave clearance between devices, check that the 32 A load is not continuously at full rating and test the residual function on a regular schedule.

Information to send with an RFQ for 411161

  • Reference 411161 and the quantity, including spares for panel maintenance.
  • Rated current (32 A), curve (C) and residual current type (AC, A or F).
  • Supply voltage and number of poles to be switched.
  • Board layout and busbar type.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as a technical data sheet or a compliance statement.

Storage, handling and spares for the Legrand 411161

Keep Legrand 411161 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.

  • Check the label and order code on every unit against the drawing before it goes into the panel.
  • Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
  • Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
  • Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.

When you plan spares for a project, group the Legrand 411161 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.

Documents and quotation

The Legrand technical data sheet that covers 411161 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.

To request a quotation, send reference 411161, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.

Other Models in the Legrand Dx3 Rcbo Range

Seven Star LLC supplies models from the Legrand Dx3 Rcbo range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Legrand 411192 DX3 4P 63 A C-Curve RCBO 30 mA ACCircuit BreakersView details
Legrand 411161 DX3 2P 32 A C-Curve RCBO 30 mA ACCircuit BreakersYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.

Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.

Legrand company profile

Headquarters Limoges, France
Listing Euronext Paris
Brands Legrand, Bticino, Cablofil, Zucchini
Product families DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS

Legrand DX3 circuit breakers

DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.

Ordering Legrand breakers: what we need

Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.

Facts checked against Legrand's published corporate information, October 2026.

FAQ

Questions about the Legrand 411161 DX3 2P 32 A C-Curve RCBO 30 mA AC

Answers from our engineering team on installation, compatibility and integration.

01What is 411161?
It is a Legrand DX3 two-pole RCBO rated 32 A with a C curve and 30 mA AC-type earth-leakage protection, 4 modules wide, for 230 V AC circuits.
02Does 411161 switch the neutral?
Yes. Both poles are protected and the neutral conductor is switched concurrently with the phase, which isolates the circuit completely when the device trips or is operated.
03What is the breaking capacity of 411161?
The product page lists 6 kA under EN 61009 and 10 kA under IEC 60947-2, together with current limiting class 3.
04How do I test 411161?
Close the device with the circuit energised and press the test button on the front. It should trip; then reset it, and record the date in the maintenance log.
05How is 411161 different from 411053?
411161 is a two-pole AC-type device four modules wide with both poles protected, while 411053 is a 1P+N type A device two modules wide with only the phase protected.