Phoenix Contact UT 10-PE Protective Earth Terminal Block

Description

UT 10-PE: protective earth block for 10 mm² conductors

The UT 10-PE is the larger sibling of the UT 4-PE: a green-yellow protective earth block for conductors up to 16 mm² rigid or 10 mm² flexible. It has two screw connections and a grounding foot that connects it to the rail.

Order number 3044173 follows IEC 60947-7-2. It is used where bigger earth conductors, such as 10 mm² main bonding or cable armour earthing, must be terminated on a rail. Seven Star LLC supplies the UT 10-PE in Oman and the GCC as an independent supplier in Muscat.

Technical specifications of the UT 10-PE

Parameter Specification
Manufacturer / part number Phoenix Contact UT 10-PE (order no. 3044173)
Type Ground modular terminal block, screw connection, 2 connections
Colour Green-yellow
Nominal cross section 10 mm²
Conductor range Rigid 0.5 to 16 mm²; flexible 0.5 to 10 mm² (connection capacity)
Screw thread / torque M4 / 1.5 to 1.8 Nm
Standard IEC 60947-7-2
Grounding foot Yes
Explosion protection marking on page II 2 GD Ex eb IIC Gb
Operating temperature -60 to 110 °C
Housing material PA, UL 94 V0
Mounting NS 35/7.5 and NS 35/15

Earth bonding with the UT 10-PE

The block makes its rail connection through the foot at the base. For bonding currents to be carried safely, the rail needs a good conductive path to the earth bar and its fixing screws must be tight on bare metal. If the rail is only touched by a painted surface, the earth path will be unreliable even though the block itself is sound.

The M4 screw is tightened at 1.5 to 1.8 Nm. A ferrule or lug on the conductor makes a better joint than bare strands, and the data sheet shows rigid conductors of 0.5 to 16 mm² and flexible conductors up to 10 mm².

Where the UT 10-PE fits in a terminal row

The UT 10-PE is intended for the main earth of a panel: incoming protective conductor, earth for the supply cable shield and bonding of metal parts. It sits at the end of a row of UT 10 power blocks and a UT 4 or UT 6 row, so that every circuit has a nearby earth terminal.

A smaller UT 4-PE or UT 6-PE can be used for branch circuits, while the UT 10-PE collects the main conductor.

Selection and ordering checklist for the UT 10-PE

  • Earth conductor size and type.
  • Whether the cable gland and armour require extra terminals.
  • Hazardous-area marking requirements (the page lists II 2 GD Ex eb IIC Gb).
  • Rail bonding to the earth bar.
  • Colour and marking of the surrounding terminals.
  • Packing quantity.

Installation, commissioning and maintenance of the UT 10-PE

Clean paint from rail contacts, mount the block, terminate the conductor with a ferrule at 1.5 to 1.8 Nm and measure continuity to the earth bar. Do not combine PE and load circuits in one block.

Record the earth test values in the commissioning file. For Ex installations keep the certificate and use only the accessory listed on the product page.

Typical applications in Oman and the GCC

In Oman and the GCC the UT 10-PE is used in motor control centres, instrument rooms, solar plants and substations where main earth conductors of 10 mm² are terminated on a rail. Heat and sand require tightly closed enclosures and good earthing, since faults to earth must clear quickly.

It is also used in hazardous locations as part of Ex e enclosures, within the limits of the certificate.

Practical design notes for the UT 10-PE

The UT 10-PE is typically the main earth point of a panel, so it deserves more planning than the small PE blocks. Decide first which conductors will land on it: the incoming protective conductor, shield drains from power cables, and bonding conductors from doors and mounting plates. Then count the clamps; each block has two connections, and a rule of one protective conductor per clamp keeps the joints reliable.

The rail must be able to carry the fault current expected at the panel. A short stretch of standard rail is adequate for small fault levels, but for high fault current a separate bonding conductor from the main earth bar to the earth side of the cabinet is better than relying on rail contact alone. Because the grounding foot and the rail work together, any rail section that is added later must be bonded as carefully as the first.

Also consider the environment. In coastal areas of the Gulf, salt and humidity attack unprotected metal over time, so check the rail finish and the joints at each scheduled inspection and measure the continuity again after any rework. In hazardous areas, keep the certificate and installation instructions with the panel documents, and never replace a certified block or accessory with an uncertified lookalike.

Comparison with neighbouring UT sizes

Device Distinguishing data
UT 4-PE (3044128) PE, 4 mm², M3
UT 6-PE (3044157) PE, 6 mm²
UT 10-PE (this part, 3044173) PE, 10 mm², M4
UT 10 (3044160) Grey power block, 57 A

Information to send with an RFQ for the UT 10-PE

  • Full part number UT 10-PE and quantity in pieces (the page lists a packing unit of 50).
  • Conductor size.
  • Ex requirement and zone.

Documents and quotation

Send us the part number UT 10-PE and the quantity you need, and we will confirm which official documents are available for this item. Seven Star LLC is an independent supplier in Muscat and quotes for projects across Oman and the GCC; we do not act on behalf of the manufacturer.

Please also tell us the delivery location and the project timeline so that availability can be checked before you commit to a schedule.

Other Models in the Phoenix Ut Terminal Range

Seven Star LLC supplies models from the Phoenix Ut Terminal range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Phoenix Contact UT 4 Feed-Through Terminal Block, 32 AControllers & Data AcquisitionView details
Phoenix Contact UT 6 Feed-Through Terminal Block, 41 AControllers & Data AcquisitionView details
Phoenix Contact UT 10 Feed-Through Terminal Block, 57 AControllers & Data AcquisitionView details
Phoenix Contact UT 16 Feed-Through Terminal Block, 76 AControllers & Data AcquisitionView details
Phoenix Contact UT 4-PE Protective Earth Terminal BlockControllers & Data AcquisitionView details
Phoenix Contact UT 10-PE Protective Earth Terminal BlockControllers & Data AcquisitionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Phoenix Contact UT 10-PE Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.

Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.

Phoenix Contact company profile

Founded 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft
Headquarters Blomberg, Germany
Ownership Family-owned (Eisert and Stührenberg families)
Key invention The modular terminal block on a DIN rail, 1928
Product families CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers

Milestones

  • 1923: Hugo Knümann founds the company in Essen.
  • 1928: The first modular terminal block is developed.
  • Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.

Phoenix Contact parts listed on this page

The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.

Phoenix Contact products we list

Family Examples
Isolator & Barrier 2906799 TTC-6-2X1-24DC-UT Surge Protector, MACX MCR-EX-SL-RPSSI-I Signal Isolator, MINI MCR-2-UI-UI 3-Way Signal Conditione…, PLT-SEC-T3-230-FM Type 3 Surge Protectio…
Power Modules QUINT-PS/1AC/24DC/10 QUINT Power Supply, QUINT4-PS/1AC/24DC/10 Power Supply, TRIO-PS-2G/1AC/24DC/10 Power Supply, UNO-PS/1AC/24DC/100W Power Supply
Automation Accessories PLC-RSC-24DC/21 Relay Module, PSR-SCP-24DC/ESP4/2X1/1X2 Safety Relay (…

Ordering Phoenix Contact components: what we need

Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.

Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.

FAQ

Questions about the Phoenix Contact UT 10-PE Protective Earth Terminal

Answers from our engineering team on installation, compatibility and integration.

01What is the UT 10-PE for?
It terminates protective earth conductors up to 16 mm² and bonds them to the rail.
02Which conductor sizes?
Rigid 0.5 to 16 mm² and flexible 0.5 to 10 mm².
03What torque is specified?
1.5 to 1.8 Nm for the M4 screw.
04What marking is listed?
II 2 GD Ex eb IIC Gb; check the certificate before use in a hazardous area.
05Does it carry load current?
No; it is for protective earth only.