Brand: Kentec
Kentec Syncro ASM MA80162M2 Marine Fire Panel, 2 Loop
Description
The Kentec Syncro ASM MA80162M2 is the marine and offshore version of the Syncro AS analogue addressable fire control panel, here with two detection loops and the Apollo protocol. Kentec describes it as certified with a host of classification societies and Marine Equipment Directive approved, suitable for small to medium vessels, and compatible with marine-approved devices from Apollo Fire Detectors and Hochiki. The datasheet DS51 and manual Man-1096M (Issue 21) are summarised below.
Marine-specific features
- Supports Apollo Discovery and Hochiki ESP protocols; expandable from 1 to 2 loops.
- Up to 64 Syncro ASM panels may be networked for integrated control of over 16000 fire alarm points.
- Optional Voyage Data Recorder interface outputs standard NMEA 0183 and can be fitted inside any panel on the network.
- Compatible with View Marine repeaters; a Marine Mode is described in the manual, with an IMO FSS Code configuration appendix.
- Two programmable sounder circuits, five inputs, three relays, 3 A supply, event log of 500 events.
Technical specification
Data from DS51 and Man-1096M.
| Parameter | Specification |
|---|---|
| Product code | MA80162M2: Apollo, 16 zones, 2 loops, no printer, 385 x 310 x 90 mm |
| Other Lite and loop options | MA80161M2 (Apollo, 1 loop); MH80161M2 and MH80162M2 (Hochiki, 1 and 2 loops) |
| Construction | 1.2 mm mild sheet steel, epoxy powder coated, grey; IP30 |
| Weight | 6 kg (standard panel) |
| Display | 8 lines of 40 characters graphic LCD |
| Power supply | 24 V DC, 3 A; mains fuse 1.6 A 250 V |
| Battery | Two 12 V 7 Ah sealed lead acid (maximum 7 Ah per datasheet); final battery voltage 19 V +/- 1 V per manual |
| Battery charge | 27.6 V DC nominal, temperature compensated; 0.7 A; fuse 20 mm 3.15 A |
| Detection loop | 400 mA; 126 Apollo or 127 Hochiki ESP devices per loop (252 or 254 on a 2-loop panel), per manual |
| Sounder outputs | Fused at 1 A each |
| Relays | Fault, fire and alarm contacts 30 V DC, 1 A |
| Aux 25 V supply | Fused at 500 mA |
| Network | RS485, up to 64 panels, fully fault tolerant optional card |
| Ports | RS232 printer and PC; RS485 serial expansion |
| Configuration | Loop Explorer PC utility; download lead S187 or economy X187LS |
Choosing a version
The marine range is MA for Apollo and MH for Hochiki, followed by 8016, the loop count (1 or 2) and the M2 enclosure code. Choose the protocol that matches the marine-approved detectors on the vessel or platform, then the loop count. Optional items such as the Voyage Data Recorder interface and View Marine repeaters are separate. Because approval certificates are listed by Kentec for classification societies, the buyer should request the exact certificate for the vessel class before ordering.
Installation notes from the manual
The manual specifies a clean, dry location free from shock and vibration, with temperature in the range -5 to +35 C and humidity not above 95 percent. Cable glands must be fitted and screens earthed to maintain EMC compliance, and only the required knockouts should be removed to protect the IP30 rating. Keep a copy of the configuration file on the vessel so service agents can restore the correct programme. Batteries are connected only after mains is applied, and the 3.15 A battery fuse protects against excessive current draw.
Typical applications
Marine and offshore fire alarm systems on small to medium vessels, supply boats, workboats and platforms, where addressable detection, networked repeaters and a voyage data recorder interface are needed. Confirm class and flag-state requirements for your project.
Selection and installation notes
A fire alarm control panel is selected from the number of loops or zones, the devices to be connected, the standby battery duration and the standard the project requires. It must be designed, installed, programmed and commissioned by competent fire system engineers to the code and authority rules for the project, with a cause and effect plan, correct battery sizing, cable of the specified type and a full test of every device and output before handover. Confirm the certification needed for the project with the authority before purchase.
For marine and offshore use, check the approvals required by the vessel or platform class before purchase and keep the commissioning records with the site documents.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Documents and quotation
You can open the datasheet and manual from this page before deciding. Seven Star LLC works as an independent supplier in Muscat. Compare other models in the fire alarm panels in the Logic Controllers category, or tell us the protocol and how many panels you need.
Frequently asked questions
What is the difference between Syncro AS and Syncro ASM?
Syncro ASM is based on Syncro AS but is certified for marine use, supports Apollo and Hochiki marine devices and offers the VDR interface.
Does it have a Voyage Data Recorder interface?
Yes, as an option. It outputs standard NMEA 0183 and can be fitted inside any panel on the network.
How many panels can be networked?
Up to 64 panels, giving over 16000 fire alarm points.
Which protocols are supported?
Apollo Discovery and Hochiki ESP, selected by the MA or MH product code.
Which battery size does it use?
Two 12 V 7 Ah sealed lead acid batteries, the maximum stated in the datasheet.
Datasheets & Documents
Reviews (0)
How would you rate this product? Cancel reply
About brand
Kentec Electronics is a British manufacturer of fire alarm and extinguishant control panels, founded in 1985 in Kent and headquartered in Dartford. It began by assembling its first panel in a converted shed to give independent installers an alternative to the large manufacturers. Kentec exports to more than 80 countries and received the King's Award for Enterprise in International Trade in 2026.
Seven Star LLC is an independent supplier in Muscat. We list Kentec panels with the manufacturer datasheet and manual on each page, for fire alarm contractors and facilities in Oman and the GCC.
Kentec company profile
| Founded | 1985, Kent, England |
|---|---|
| Headquarters | Dartford, Kent |
| Exports | More than 80 countries |
| Approvals | EN 54 and UL/FM listed panels |
| Product families | Sigma conventional fire panels, Sigma XT and ZXT extinguishant release panels, Syncro AS addressable fire panels, Syncro XT+ extinguishant panels, UL864 panels, repeaters and marine panels |
Milestones
- 1985: Kentec builds its first panel in Kent.
- 2026: Kentec receives the King's Award for International Trade.
Kentec product series
Fire alarm panels include the Syncro AS two-loop addressable panel, the Syncro ASM marine version, the Sigma CP four-zone conventional panel with the Sigma CP-R repeater, and the UL864 listed Sigma A-CP conventional panel.
Extinguishant control panels include the Sigma XT+ four-zone two-area panel, the Syncro XT+, the single-area Sigma ZXT and the UL/FM Sigma A-XT releasing panel, and the Sigma Si is a six-lamp extinguishant status unit for doors of protected rooms. Datasheets state the standards by model, such as EN 54-2, EN 54-4, EN 12094-1 and UL864.
Where Kentec panels are used
Fire alarm systems in commercial and industrial buildings, and gas suppression release for server rooms, control rooms, switchgear rooms and archives, as well as marine installations.
Kentec products we list
Ordering Kentec panels: what we need
Send the Kentec part number, the number of loops or zones, the detector protocol for addressable panels, the extinguishing agent and number of areas for release panels, and the standard (EN or UL) required.
Facts checked against Kentec's catalogues and the 2026 King's Awards profile, October 2026.
Browse Kentec products by category: Logic Controllers.
Related products
Frequently Asked Questions
Syncro ASM is based on Syncro AS but is certified for marine use, supports Apollo and Hochiki marine devices and offers the VDR interface.
Yes, as an option. It outputs standard NMEA 0183 and can be fitted inside any panel on the network.
Up to 64 panels, giving over 16000 fire alarm points.
Apollo Discovery and Hochiki ESP, selected by the MA or MH product code.
Two 12 V 7 Ah sealed lead acid batteries, the maximum stated in the datasheet.