Brand:

Hydac EDS 8446-1-0100-000 Compact Pressure Switch, 100 bar

Description

A compact switch with a colour-coded switching display

The Hydac EDS 8446-1-0100-000 (HYDAC part number 920859) is the one-output, 100 bar version of the EDS 8000 series. It is simple to set up with two keys and a four-digit display, and the display backlight changes between red and green to show the state of the switching output during operation. Menu names and symbols follow the German VDMA 24574-1 specification for pressure switches.

With a body of only about 70 g, a G1/4 A stainless steel connection and an M12x1 plug, it replaces mechanical pressure switches on pumps, clamping circuits and machine tools where an easily visible set point is helpful.

Technical specifications

Parameter Specification
HYDAC part number 920859
Model code EDS 8446-1-0100-000
Measuring range 0 to 100 bar
Overload pressure 200 bar
Burst pressure 500 bar
Mechanical connection G1/4 A ISO 1179-2, male; 20 N·m
Material of connection Stainless steel
Seal FKM
Switching output 1 PNP transistor output
Switching current 250 mA max. per output; more than 100 million cycles
Switch point range 1.0 to 100 bar; increment 0.2 bar
Minimum difference SP to RP 1.0 bar
Repeatability 0.5 % FS max.
Display 4-digit LED, 4.5 mm digits, red or green backlight
Electrical connection Male M12x1, 4-pole (mating connector not supplied)
Operating temperature -25 to +100 °C (FKM seal; -40 °C on request)
Fluid temperature -25 to +125 °C
Display temperature range -15 to +70 °C
Compensated temperature -25 to +85 °C
Protection class IP 67 with mating connector
Vibration / shock 10 g / 50 g
Weight Approx. 70 g
Approvals as printed CE (EN 61000-6-1/2/3/4); cUL, certificate no. E318391

Setting the switch

Switch point (SP) and switch-back point (RP) are entered with the two keys; pressure window function uses FL and FH limits. The datasheet lists switching delay times and N/O or N/C function as further adjustable parameters. The minimum difference between SP and RP is 1 bar on the 100 bar range, so hysteresis cannot be made tighter than that.

Ordering notes

Within EDS 8 4 4 6 the pattern shows the metric G1/4 A version with one output (1 in the middle block). The datasheet that goes with this page is the USA edition, which prints SAE-6 psi codes such as EDS 827-2-… with ranges of 500 to 9000 psi, so use it for series features and wiring while the bar range and thread above come from the catalogue entry. Buy the M12 cable separately, as no mating connector is supplied.

The switch is small enough to fit directly into a manifold test port, yet the display stays readable because the backlight colour is visible from a distance, which helps during commissioning. Check the 250 mA switching current against the load, and use a relay or interposing module for coils that draw more. Fit the M12 connector fully to keep the IP 67 rating.

Compact electronic switches like this one replace mechanical pressure switches where drift, vibration and wear are a problem. Record the switch points and hysteresis you require, because they are set by programming rather than by a mechanical screw, and note them on the commissioning sheet.

Selection considerations for an electronic pressure switch

Choose the measuring range from the normal operating pressure and the highest pressure the switch will see, including pressure peaks from valve switching or pump start-up. Peaks above the measuring range shorten the life of any pressure sensor even when they stay below the overload limit, so on circuits with strong pressure spikes a higher range may be the better choice. A switch point near the middle of the range generally gives a better working margin than one set at the very top or bottom.

Next consider the function of the output. A single PNP output covers most tasks such as pump control, pressure monitoring for clamping, or a low-pressure alarm. The window function with FL and FH limits is useful when the machine should only run while pressure is between two values. Confirm that the fluid is compatible with the stainless steel connection and the FKM material listed in the specification.

Installation and commissioning practice

Install the switch on a clean, deburred port with the correct thread form and tighten it to the torque given in the specification. Where possible, mount it so that the display faces the operator or maintenance technician and can be read without removing guards. Keep it away from strong heat sources so that the electronics and display stay within their temperature ranges, which are narrower than the fluid temperature range. Use a correctly wired M12 cable and route it away from power cables.

At commissioning, check that the displayed pressure matches a reference gauge, then program the switch point, switch-back point and any delay times required by the control logic. Test the output by raising and lowering pressure through the set values and confirm that the controller responds as intended. Note the final settings on the commissioning sheet and on the machine documentation.

Integration in hydraulic and process systems

The switch typically feeds a PLC input or a small relay circuit. In hydraulic power units it can confirm system pressure before a machine cycle starts, signal pressure loss, or control a pump in an accumulator circuit. In lubrication and cooling systems it can provide a simple pressure-healthy signal. Because the switch has only one output, a separate device or a transmitter may be needed when both control and alarm functions are required at different pressures.

Operation in GCC conditions

Hydraulic power units in Oman and the GCC often run in hot workshops or outdoors in strong sun. Shade the switch from direct sunlight, which can raise the housing temperature beyond the ambient and make the display hard to read. Keep the M12 connection fully engaged so that dust and moisture stay out, and check the switch points periodically against a reference gauge as part of routine maintenance.

What to include in your RFQ

Provide the full model code, the HYDAC part number, quantity, and the fluid and pressure range of the application, plus the required output function.

Documents and quotation

The EDS 8000 datasheet is attached. Send the full model code and quantity. Related: our pressure instrumentation range.

Datasheets & Documents
  • PDF Datasheet Hydac EDS 8000 electronic pressure switch datasheet (USA edition) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

Frequently Asked Questions

What range does the EDS 8446-1-0100-000 cover?
0 to 100 bar, with 200 bar overload and 500 bar burst pressure.
How many outputs does it have?
One PNP transistor switching output of up to 250 mA.
How does the display show the switching state?
The backlight is red or green depending on the output state.
Which connector is used?
A four-pole M12x1 male plug; the mating connector is not supplied.
What is the repeatability?
0.5 % of full scale at most, according to the catalogue entry.