Brand:

Carlo Gavazzi ICB12S30N04NO M12 Inductive Proximity Sensor

Description

An M12 inductive sensor with 4 mm range and NPN normally open output

The Carlo Gavazzi ICB12S30N04NO is an inductive proximity switch in a nickel-plated brass M12 housing with a 30 mm thread length (short body) and a 2 m cable. It senses ferrous and non-ferrous metal targets at a nominal sensing distance of 4 mm in a non-flush version, which means the active face needs a free zone of non-damping material around it when it is mounted in a metal bracket. The output is an NPN open-collector transistor, normally open, rated up to 200 mA.

The sensor operates from 10 to 36 V DC with protection against reverse polarity, short circuit and transients, a yellow LED that shows output ON, and a blinking LED at 2 Hz as a short-circuit or overload indication. The enclosure is rated IP67 and the housing front is a grey thermoplastic polyester cap with laser-engraved marking.

Technical specifications

Parameter Specification
Manufacturer / series Carlo Gavazzi, ICB inductive sensors (standard range)
Part number ICB12S30N04NO
Housing M12 x 1, nickel-plated brass body, grey thermoplastic polyester front
Body length / thread length Short body / 30 mm (overall 50.8 mm with cable)
Rated sensing distance Sn 4 mm, non-flush mounting
Output NPN, normally open (target present = output ON)
Rated operational voltage Ub 10 to 36 V DC, ripple 10% or less
Output current Ie 200 mA or less at 50 C; 150 mA or less at 50 to 70 C
Off-state current 50 uA or less
No-load supply current 15 mA or less
Voltage drop 2.5 V DC max. at 200 mA
Protection Reverse polarity, short circuit, transients (1 kV / 0.5 J)
Power ON delay 20 ms or less
Operating frequency 2000 Hz or less
Assured operating distance Sa 0 to 0.81 x Sn
Effective operating distance Sr 0.9 to 1.1 x Sn
Repeat accuracy / hysteresis 10% or less / 1 to 20% of sensing distance
Indication Yellow LED output ON; LED blinks at 2 Hz on short circuit or overload
Connection Cable 4.1 mm dia. x 2 m, 3 x 0.25 mm2, grey PVC, oil proof
Ambient temperature Operating -25 to +70 C; storage -30 to +80 C
Degree of protection IP67
Weight (cable version, with nuts) 120 g max.
Tightening torque 10 Nm
MTTFd 750 years at 50 C
Standards and approvals listed IEC 60947-5-2; cULus (UL 508); cCSAus for hazardous locations Class I Div 2, groups A to D, T5, Type 4 enclosure, Ta -25 to +60 C
EMC test levels ESD 8 kV air / 4 kV contact; 3 V/m; EFT 2 kV; 3 V conducted; 30 A/m magnetic

Mounting a non-flush M12 sensor

The datasheet distinguishes 2 mm flush types (marked F02) from 4 mm non-flush types (marked N04). A non-flush sensor reaches further but must project beyond the metal around it. The datasheet installation drawings give the minimum free zone and the spacing between neighbouring sensors in terms of the nominal distance Sn and the sensor diameter d (12 mm), and they require at least 6 x Sn between two sensors mounted facing each other. Follow those drawings, because a sensor sunk into metal that is meant for non-flush mounting loses range or switches unreliably.

Wiring and selection notes

An NPN output is a sinking output that pulls the signal toward 0 V, so confirm that it matches the input type of your PLC or counter. The ordering key also offers PNP outputs, normally closed versions and plug (M1) versions; check which type your controller expects. Do not exceed 200 mA, and use the derated 150 mA above 50 C. Tighten the two brass nuts to 10 Nm and mount the sensor on a fixed bracket; a mounting bracket for M12 sensors is listed as a separate Carlo Gavazzi accessory.

How the Carlo Gavazzi ICB12S30N04NO works

The sensor creates a small high-frequency field at its active face. A metal target entering the field changes the oscillation. The electronics detect the change and switch the NPN output on.

Where the ICB12S30N04NO is used

  • Position detection on machines
  • Cylinder end-of-stroke sensing
  • Counting metal parts on conveyors
  • Presence checks in assembly fixtures
  • Valve and gate position feedback

Selection checklist for the ICB12S30N04NO

  • Thread size
  • Sensing distance
  • Flush or non-flush mounting
  • Output type, NPN or PNP
  • Normally open or normally closed
  • Supply voltage
  • Cable length or connector
  • Target material

Installation, commissioning and maintenance notes for the ICB12S30N04NO

Keep a free zone around the active face in a metal bracket. Tighten the nuts to the torque on the datasheet. Wire the brown, blue and black cores to the supply and the load. Check the yellow LED with a target in front of the face. Check the cable for damage at regular intervals.

Requesting a quotation for the Carlo Gavazzi ICB12S30N04NO

Please send the quantity, the output type and the cable length. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.

ICB12S30N04NO sensor type

It is an inductive proximity switch.

ICB12S30N04NO housing

The housing is an M12 nickel-plated brass body.

ICB12S30N04NO thread length

The thread length is 30 mm.

ICB12S30N04NO sensing distance

The nominal sensing distance is 4 mm.

ICB12S30N04NO mounting

It is a non-flush version.

ICB12S30N04NO output

The output is NPN, normally open.

ICB12S30N04NO output current

The output current is up to 200 mA.

ICB12S30N04NO supply voltage

The supply is 10 to 36 V DC.

ICB12S30N04NO operating frequency

The operating frequency is up to 2000 Hz.

ICB12S30N04NO protection circuits

It has reverse polarity, short circuit and transient protection.

ICB12S30N04NO LED indication

A yellow LED shows output ON.

ICB12S30N04NO overload signal

The LED blinks at 2 Hz on short circuit or overload.

ICB12S30N04NO connection

It has a 2 m grey PVC cable with 3 cores.

ICB12S30N04NO cable size

Each core is 0.25 mm2.

ICB12S30N04NO ambient temperature

The operating range is minus 25 to plus 70 degrees C.

ICB12S30N04NO protection degree

The enclosure rating is IP67.

ICB12S30N04NO weight

The weight is 120 g maximum with nuts.

ICB12S30N04NO tightening torque

The tightening torque is 10 Nm.

ICB12S30N04NO front cap

The front is grey thermoplastic polyester with laser-engraved marking.

Sensor records for the ICB12S30N04NO

Record the location, the wiring and the date fitted.

Choosing the right ICB12S30N04NO mounting

Choose the bracket so the free zone around the face is kept.

Documents and quotation

The attached Carlo Gavazzi datasheet covers the ICB M12 family with the full type selection table, specifications, dimensions and installation drawings. For a quotation on ICB12S30N04NO, send the quantity, the supply voltage, the output type your controller needs, the target material and the sensing distance required. Related items are listed under Inductive Proximity Sensors.

Datasheets & Documents
  • PDF Datasheet Carlo Gavazzi ICB M12 datasheet (EN) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Carlo Gavazzi is an electronics group founded in 1931 and headquartered in Steinhausen, Switzerland, making components for industrial and building automation, including energy meters, monitoring relays, solid state relays, sensors and soft starters.

Seven Star LLC is an independent supplier in Muscat. We list Carlo Gavazzi components for panel builders and building services contractors in Oman and the GCC.

Carlo Gavazzi product series

Energy meters include the EM340DINAV23XS1X three-phase meter with RS-485, the EM540DINAV23XS1PFA three-phase MID energy analyzer, the EM111DINAV81XS1X single-phase analyzer and the WM50AV53HBC multichannel power analyzer.

Switching and control includes the RM1A48D50 50 A solid state relay, the RGC1A60D25KKE 25 A solid state contactor, the RSGT4025E0V10C 25 A three-phase soft starter and the DPB01CM44 three-phase voltage monitoring relay. The ICB12S30N04NO is an M12 inductive proximity sensor.

Solid state relays and contactors switch heaters and other resistive loads silently and with long life, while soft starters reduce starting current and mechanical shock on pumps and fans. Carlo Gavazzi energy meters and analyzers are available with MID approval for billing and with Modbus RTU, Modbus TCP or M-Bus for building management systems.

Where Carlo Gavazzi products are used

Energy sub-metering in buildings, heating and process control with solid state switching, pump and fan soft starting, phase and voltage supervision of motors, and object detection on machines.

Ordering Carlo Gavazzi products: what we need

Send the full ordering code, which defines input, supply, outputs and communication, or give the voltage, current, load type and interface needed.

Frequently Asked Questions

What does the ICB12S30N04NO sense?
Metal targets, at a nominal sensing distance of 4 mm in non-flush mounting.
What output does it have?
An NPN open-collector output, normally open, up to 200 mA.
What supply voltage does it need?
10 to 36 V DC with reverse polarity, short-circuit and transient protection.
How is it connected?
Through an integral 2 m cable, 3 x 0.25 mm2, in grey oil-proof PVC.
What is its protection rating?
IP67, with an operating temperature of -25 to +70 C.